Felicity Solar 80 A 48 V Parallel MPPT Solar Charge Controller
The Felicity Solar SCCM8048-P Charge Controller is engineered to optimize your solar energy system with a maximum charging current of 80A and an impressive efficiency of 98%. Supporting 12V, 24V and 48V battery systems with automatic voltage detection, it ensures reliable and efficient energy management.
Key Features
- Intelligent Maximum Power Point — Tracking technology increases efficiency 25%–30%
- Compatible for PV systems — in 12V, 24V or 48V
- Three-stage charging optimizes battery — performance
- Automatic battery voltage detection
- Supports various lead-acid batteries, — AGM and gel battery
- Integrated intelligent slot compatible — with MODBUS communication
Specifications
Electrical
| Maximum Input Power | 24V-2200W |
| PV Array MPPT | 12 VDC/24VDC/48 VDC |
| PV Array voltage & Battery current | Maximum Battery Current Battery Current(Amps) 130 145 Array Voltage(Volts) For SCCM8048-P |
| Voltage Range | 15-130VDC/30-130VDC 60-130VDC |
| Maximum Battery Current | 80 A |
| Nominal System Voltage | 12V, 24V, 48V DC (Auto detection) |
| Maximum Solar Input Voltage | 145 V |
| PV Start-up Voltage | 20 V |
| PV Array MPPT Voltage Range (12V battery) | 15-130VDC |
| PV Array MPPT Voltage Range (24V battery) | 30-130VDC |
| PV Array MPPT Voltage Range (48V battery) | 60-130VDC |
| Maximum Input Power (12V) | 1100 W |
| Maximum Input Power (24V) | 2200 W |
| Maximum Input Power (48V) | 4400 W |
| Transient Surge Protection | 4500 W / port |
| Charging Algorithm | 3-Step |
| Charging Stages | Bulk, Absorption, Float |
| Temperature Compensation Coefficient | -5 mV/°C/cell @ 25°C ref |
| Protections | Solar HV disconnect/reconnect, Battery HV disconnect/reconnect, High temperature disconnect/reconnect |
| Special Function | Match the inverter to the MPPT controller (MPPT-match) |
Mechanical
| Product Weight | 6.8 Kg |
| Product Size (W x H x D) | 338 x 206 x 135 mm |
| Display | LCD (built-in) |
| Installation | Indoor wall-mount |
Environmental
| Heatsink temperature & Battery current | Maximum Battery Current Battery Current(Amps) 60 62.5 65 67.5 70 72.5 75 77.5 80 Heatsink Temperature (degrees C) |
| Humidity | 0%-90%RH(No condensing) Match the MPPT flashes, indicating that the inverter is |
| Storage Temperature | - 25°C to 75°C |
| Temperature compensation range | 0 °C to +50 °C |
| Ambient Temperature Range | 0°C to +55°C |
| Enclosure Rating | IP20 (Indoor & Vented) |
| Warranty | 2 Years |
FAQs
What are the main performance specifications of the SCCM8048-P charge controller?
The SCCM8048-P charge controller has a maximum charging current of 80A and achieves a maximum efficiency of 98%. It supports 12V, 24V and 48V battery systems with automatic voltage detection.
Is the SCCM8048-P charge controller compatible with different battery types?
Yes, the SCCM8048-P is compatible with various battery types, as it supports different charging voltages such as absorption voltage at 14.40V, float voltage at 13.60V, and equalization voltage at 14.60V.
What are the physical specifications of the SCCM8048-P charge controller?
The SCCM8048-P has an IP20 rating, indicating it is protected against solid objects larger than 12.5mm. For detailed dimensions and weight, please refer to the product manual.
What are the installation requirements for the SCCM8048-P charge controller?
The SCCM8048-P should be installed in a location where the operating temperature is between 0°C and 55°C. Ensure proper ventilation and avoid exposure to moisture due to its IP20 rating.