Voltronic Power Atlas Line Interactive
The Voltronic Power Atlas Line Interactive UPS is designed to provide seamless power protection with a voltage range of 110/120 VAC or 220/230/240 VAC. Its auto-sensing frequency range of 50/60 Hz ensures adaptability and efficiency, making it an ideal choice for safeguarding your critical devices. The Atlas Line Interactive UPS is perfect for home offices, small businesses, and IT equipment, offering reliable power backup and protection against voltage fluctuations.
Key Features
- Excellent microprocessor control guarantees high — Excellent microprocessor control guarantees high reliability
- Boost and Buck AVR for — Boost and Buck AVR for voltage stabilization
- Auto restart while AC is — Auto restart while AC is recovering
- Pure sine wave
- Off-mode charging
- Cold-start function
- Built-in USB communication port and — Built-in USB communication port and RJ-45 phone protection
- Provides battery backup and surge — Provides battery backup and surge protected outputs
- Easy replacement battery compartment
- Hot-swappable battery design
- Optional Coax Surge Protection for — Optional Coax Surge Protection for TV antenna/network
- Optional 5V USB charger port — Optional 5V USB charger port for mobile devices
- Site Wiring Fault for 120VAC — Site Wiring Fault for 120VAC models
- Battery Independent: turn ON and — Battery Independent: turn ON and operate in the AC mode providing surge protection and AVR function without the batteries connected
- Comply with energy Star 2.0 — Comply with energy Star 2.0 for 120VAC models
Specifications
Electrical
| Voltage | 110/120 VAC or 220/230/240 VAC |
| Voltage Range | 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC |
| Frequency Range | 50/60 Hz ± 5Hz(Auto sensing) |
| AC Voltage Regulation (Batt. Mode) | ±10% |
| Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ±1 Hz |
| Transfer Time | 6ms typical, 10ms max |
| Waveform (Batt. Mode) | Pure Sinewave |
| Typical Recharge Time | 4-6 hours recover to 90% capacity |
| USB Charger ports | Type A x 2 |
| Output Voltage | 5 V±5% |
| Load current | 2.1A(MAX) |
| LCD Display | Input/output voltage, input/output frequency, load in VA/Watts, battery capacity, estimated remaining runtime, site wiring fault indications. |
| Low Battery | Sounding every second |
| Overload | Sounding every 0.5 second |
| Fault | Continuously sounding |
| Optional USB Port | Supports Windows® Family, Linux and MAC |
| Compliance & Standards | 110/120VAC model: cTUVus (standard:UL 1778), FCC Part 15 Class B, ENERGY STAR (USA) / 220/230/240VAC model: CE, EN 62040-1:2008/A1:2013, IEC 62040-1:2008/A1:2013 |
Mechanical
| Dimension, D x W x H (mm) | 288 x 99 x 280 / 410 x 99 x 280 |
| Net Weight (kgs) | 7.4 / 7.9 / 8.5 / 11.8 / 13.1 |
| Weight | 7.4 / 7.9 / 8.5 / 11.8 / 13.1 |
Environmental
| Full Protection | Overload, discharge, and overcharge protection |
| Humidity | 0-90 % RH @ 0- 40°C (Non-condensing) |
| Noise Level | Less than 40dB / Less than 45dB |
Certifications: cTUVus, FCC, ENERGY STAR, CE, EN 62040-1, IEC 62040-1
FAQs
What are the main performance specifications of the Atlas Line Interactive UPS?
The Atlas Line Interactive UPS offers a voltage range of 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC, with a frequency range of 50/60 Hz ± 5Hz. It provides AC voltage regulation in battery mode at ±10% and a pure sinewave output.
Is the Atlas Line Interactive UPS compatible with different battery types or solar panels?
The UPS uses a 12 V/7 Ah battery and is not specifically designed for direct solar panel integration. It is primarily intended for grid power backup.
What are the physical specifications of the Atlas Line Interactive UPS?
The physical dimensions and weight of the UPS are not specified in the provided details. It does not have an IP rating, indicating it is intended for indoor use.
What are the installation requirements for the Atlas Line Interactive UPS?
Installation requires a stable indoor environment with access to a compatible power source. Ensure proper ventilation and avoid placing the UPS in direct sunlight or near heat sources.
What warranty information is available for the Atlas Line Interactive UPS?
Warranty details are not specified in the provided information. It is recommended to contact Voltronic Power or your supplier for specific warranty terms.
What certifications and standards does the Atlas Line Interactive UPS meet?
The UPS is certified with cTUVus, FCC, ENERGY STAR, CE, EN 62040-1, and IEC 62040-1, ensuring compliance with international safety and efficiency standards.
What are the operating conditions for the Atlas Line Interactive UPS?
The UPS should be operated in a temperature-controlled environment, but specific temperature and humidity ranges are not provided. Avoid extreme conditions to ensure optimal performance.
What are the key features and benefits of the Atlas Line Interactive UPS?
Key features include a pure sinewave output, fast transfer time of 6ms typical, and full protection against overload, discharge, and overcharge. It also includes two USB charger ports for additional device charging.