{"product_id":"power-42u-120hv","title":"Voltronic Power +Power 42U-120HV","description":"\u003cp\u003eThe +Power Modular UPS by Voltronic Power offers unparalleled reliability with its nominal voltage of 3 x 380VAC\/400VAC\/415VAC. Designed for both balanced and imbalanced loads, it ensures steady voltage regulation, making it a top choice for critical power applications. Ideal for data centers, telecommunications, and industrial applications where uninterrupted power is crucial.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency online double conversion\u003c\/strong\u003e — High efficiency online double conversion technology\u003c\/li\u003e\n\u003cli\u003eUnity output power factor\u003c\/li\u003e\n\u003cli\u003eModular design lowers MTTR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN+1 or N+X parallel redundancy\u003c\/strong\u003e — N+1 or N+X parallel redundancy for power guarantee\u003c\/li\u003e\n\u003cli\u003eEase of installation and maintenance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible battery configuration adapts different\u003c\/strong\u003e — Flexible battery configuration adapts different applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly reliable operation with redundant\u003c\/strong\u003e — Highly reliable operation with redundant power supply in STS\u003c\/li\u003e\n\u003cli\u003eUser-adjustable charging current\u003c\/li\u003e\n\u003cli\u003eHigh overload capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGraphic 5.7” LCD design for\u003c\/strong\u003e — Graphic 5.7” LCD design for easy management\u003c\/li\u003e\n\u003cli\u003eOptional 10\" touch LCD panel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e3 x 380VAC\/400VAC\/415VAC (3PH+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e305 - 478 VAC @ 100% load; 208 - 478VAC @ 70% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz (Auto Sensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e40Hz – 70Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 0.99 @ 100% Load, \u0026gt;0.98 @ 50% Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Distortion (THDi)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 3% @ 100% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation (Steady state)\u003c\/td\u003e\n\u003ctd\u003e≤ ± 1% Typical (balanced load); ≤ ± 2% Typical (imbalanced load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Synchronized)\u003c\/td\u003e\n\u003ctd\u003e46Hz – 54Hz or 56Hz – 64Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Capability\u003c\/td\u003e\n\u003ctd\u003e1 hour for 110%, 10 mins for 125%, 1 min for 150%, 200ms for \u0026gt;150%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Distortion\u003c\/td\u003e\n\u003ctd\u003e≤ 2% THD (Linear Load); ≤ 4% THD (Non-linear Load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 94.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/- 240V (12V x 40 pcs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/- 192V (12V x 32 pcs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloat Charging Voltage\u003c\/td\u003e\n\u003ctd\u003e2.25V \/ Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoost Charging Voltage\u003c\/td\u003e\n\u003ctd\u003e2.35V \/ Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Charging Current (Per Power Module)\u003c\/td\u003e\n\u003ctd\u003e6A for 20KW power module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart RS-232 \/ USB\u003c\/td\u003e\n\u003ctd\u003eSupports Windows® 2000\/2003\/XP\/Vista\/2008, Windows® 7\/8\/10, Linux and MAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional SNMP\u003c\/td\u003e\n\u003ctd\u003ePower management from SNMP manager and web browser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60950-1; IEC\/EN 62040-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 62040-2 Category C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimension (D x W x H) mm\u003c\/td\u003e\n\u003ctd\u003e1100 x 600 x 2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kg)\u003c\/td\u003e\n\u003ctd\u003e932\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e932\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 – 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 – 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1000m for Nominal power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e IEC\/EN 60950-1, IEC\/EN 62040-1, IEC\/EN 62040-2 Category C3\u003c\/p\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the main performance specifications of the +Power Modular UPS?\u003c\/summary\u003e\u003cp\u003eThe +Power Modular UPS offers a high efficiency of up to 94.5% and supports a nominal voltage of 3 x 380VAC\/400VAC\/415VAC (3PH+N). It maintains a power factor greater than 0.99 at full load and harmonic distortion of less than 3% at 100% load.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the +Power Modular UPS compatible with different battery types and solar panels?\u003c\/summary\u003e\u003cp\u003eYes, the UPS is compatible with a nominal battery voltage of +\/- 216V, consisting of 12V x 36 pcs, and can support a maximum voltage of +\/- 240V with 12V x 40 pcs. It can be integrated with solar panels and the grid for enhanced power solutions.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the physical specifications of the +Power Modular UPS?\u003c\/summary\u003e\u003cp\u003eThe physical dimensions and weight of the +Power Modular UPS can vary based on the specific configuration and modules used. Please refer to the detailed product manual for precise measurements and weight.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the installation requirements for the +Power Modular UPS?\u003c\/summary\u003e\u003cp\u003eInstallation requires a stable environment with appropriate ventilation. The UPS should be installed by a certified technician to ensure compliance with safety standards and optimal performance.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat warranty is offered with the +Power Modular UPS?\u003c\/summary\u003e\u003cp\u003eVoltronic Power offers a standard warranty period for the +Power Modular UPS, which typically covers parts and labor. Specific warranty terms can vary, so it's advisable to consult the purchase agreement or contact customer support for detailed information.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat certifications and standards does the +Power Modular UPS adhere to?\u003c\/summary\u003e\u003cp\u003eThe +Power Modular UPS is certified under IEC\/EN 60950-1, IEC\/EN 62040-1, and IEC\/EN 62040-2 Category C3, ensuring compliance with international safety and performance standards.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the operating conditions for the +Power Modular UPS?\u003c\/summary\u003e\u003cp\u003eThe UPS is designed to operate efficiently in a temperature range that supports optimal performance. It is important to maintain humidity levels within recommended limits to ensure reliability and longevity.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the key features and benefits of the +Power Modular UPS?\u003c\/summary\u003e\u003cp\u003eKey features include high efficiency, robust overload capability, and low harmonic distortion. These benefits ensure reliable power supply, reduced energy costs, and enhanced protection for connected equipment.\u003c\/p\u003e\u003c\/details\u003e","brand":"Voltronic Power","offers":[{"title":"Default Title","offer_id":47936678199401,"sku":"+Power 42U-120HV","price":120000.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/plus_power_ds_a9d33f86-ad86-49c8-954f-addfa3944265.jpg?v=1787308717","url":"https:\/\/www.solarinstaller.ae\/products\/power-42u-120hv","provider":"Solar Installer","version":"1.0","type":"link"}