{"product_id":"otimaii","title":"Voltronic Power Otima II","description":"\u003cp\u003eThe Otima II UPS by Voltronic Power is engineered to provide exceptional power protection with its versatile voltage options ranging from 110 to 240 VAC. Designed for both home and office environments, it ensures reliable performance with precise voltage regulation and auto-sensing frequency capabilities. Ideal for safeguarding sensitive electronics, the Otima II UPS is perfect for use in home offices, small businesses, and IT equipment, ensuring uninterrupted power supply and protection against voltage fluctuations.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePure sine wave\u003c\/li\u003e\n\u003cli\u003eUser-friendly and easy-shift LCD display\u003c\/li\u003e\n\u003cli\u003eHigh flexibility with Rack\/Tower design\u003c\/li\u003e\n\u003cli\u003eOutput power factor 0.9\u003c\/li\u003e\n\u003cli\u003eProgrammable power management outlets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECO (Efficiency Corrective Optimizer) operation\u003c\/strong\u003e — ECO (Efficiency Corrective Optimizer) operation for energy saving\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoost and Buck AVR for\u003c\/strong\u003e — Boost and Buck AVR for voltage stabilization\u003c\/li\u003e\n\u003cli\u003eHot-swappable battery design\u003c\/li\u003e\n\u003cli\u003eMultiple communications available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional HID Power Device USB\u003c\/strong\u003e — Optional HID Power Device USB Port\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e110\/115\/120\/127 VAC or 208\/220\/230\/240 VAC \/ 208\/220\/230\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceptable Voltage Range\u003c\/td\u003e\n\u003ctd\u003e81-152 VAC or 162-290 VAC \/ 162-290 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e60\/50 Hz (Auto sensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e110\/115\/120\/127 VAC or 208\/220\/230\/240 VAC \/ 208\/220\/230\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003e±1.5 % (Before battery alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003e50 Hz or 60 Hz ± 1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Crest Ratio\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Distortion\u003c\/td\u003e\n\u003ctd\u003e2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003eTypical 2-6 ms, 10ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003ePure Sinewave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECO Mode\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuck \u0026amp; Boost Mode\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Current (max.)\u003c\/td\u003e\n\u003ctd\u003e1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Voltage\u003c\/td\u003e\n\u003ctd\u003e27.4 VDC ± 1% \/ 54.8 VDC ± 1% \/ 82.1 VDC ± 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e4 hours recover to 90% capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCD Display\u003c\/td\u003e\n\u003ctd\u003eAC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault and Low Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Battery\u003c\/td\u003e\n\u003ctd\u003eSounding every 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd\u003eSounding every second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault\u003c\/td\u003e\n\u003ctd\u003eContinuously sounding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart RS-232\/USB\u003c\/td\u003e\n\u003ctd\u003eSupports Windows® 2000\/2003\/XP\/Vista\/2008, Windows® 7\/8\/10, Linux and MAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional SNMP\u003c\/td\u003e\n\u003ctd\u003ePower management from SNMP manager and web browser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Dimension, DxWxH (mm)\u003c\/td\u003e\n\u003ctd\u003e410 x 438 x 88 \/ 510 x 438 x 88 \/ 630 x 438 x 88 \/ 397 x 145 x 220 \/ 455 x 145 x 220 \/ 421 x 190 x 318\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kgs)\u003c\/td\u003e\n\u003ctd\u003e12.9 \/ 13.4 \/ 19.5 \/ 21.5 \/ 27.7 \/ 29.3 \/ 11.7 \/ 12.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e12.9 \/ 13.4 \/ 19.5 \/ 21.5 \/ 27.7 \/ 29.3 \/ 11.7 \/ 12.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Protection\u003c\/td\u003e\n\u003ctd\u003eOverload, discharge, and overcharge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0-90 % RH @ 0- 40°C (Non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003eLess than 45dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e0-3000m, 10% de-rating for over 1000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the main performance specifications of the Otima II UPS?\u003c\/summary\u003e\u003cp\u003eThe Otima II UPS offers high efficiency with an ECO mode at 97% and a battery mode efficiency of up to 90% at nominal battery voltage. It supports a wide voltage range of 110\/115\/120\/127 VAC or 208\/220\/230\/240 VAC and maintains a voltage regulation of ±1.5% in battery mode.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the Otima II UPS compatible with different battery types or solar panels?\u003c\/summary\u003e\u003cp\u003eThe Otima II UPS is equipped with two 12 V\/7 Ah batteries. It is primarily designed for use with these batteries and does not directly support solar panel integration.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the physical specifications of the Otima II UPS?\u003c\/summary\u003e\u003cp\u003eThe physical dimensions and weight of the Otima II UPS are not specified in the provided details. It is recommended to refer to the product manual or contact Voltronic Power for precise physical specifications.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the installation requirements for the Otima II UPS?\u003c\/summary\u003e\u003cp\u003eThe Otima II UPS should be installed in a well-ventilated area, away from direct sunlight and moisture. It requires a stable power source within the acceptable voltage range of 81-152 VAC or 162-290 VAC.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat warranty does Voltronic Power offer for the Otima II UPS?\u003c\/summary\u003e\u003cp\u003eVoltronic Power typically offers a standard warranty for their products, but specific warranty terms for the Otima II UPS should be confirmed with the retailer or manufacturer.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat certifications and standards does the Otima II UPS comply with?\u003c\/summary\u003e\u003cp\u003eThe Otima II UPS complies with standard certifications, ensuring it meets industry safety and performance standards. Specific certifications can be verified in the product documentation.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the operating conditions for the Otima II UPS?\u003c\/summary\u003e\u003cp\u003eThe Otima II UPS is designed to operate in a range of environmental conditions, but specific temperature and humidity ranges are not detailed. It is advisable to operate it in a controlled environment to ensure optimal performance.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the key features and benefits of the Otima II UPS?\u003c\/summary\u003e\u003cp\u003eKey features of the Otima II UPS include its pure sinewave output in battery mode, fast transfer time of 2-6 ms, and high efficiency in ECO mode. These features ensure reliable power backup and efficient energy use.\u003c\/p\u003e\u003c\/details\u003e","brand":"Voltronic Power","offers":[{"title":"Default Title","offer_id":47936732430441,"sku":"VOLTRONIC-OTIMA-II","price":1500.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/otimaii.jpg?v=1787309206","url":"https:\/\/www.solarinstaller.ae\/products\/otimaii","provider":"Solar Installer","version":"1.0","type":"link"}