{"product_id":"giant-ind-ii-ds","title":"Voltronic Power Giant iND II","description":"\u003cp\u003eThe Giant iND II by Voltronic Power is a versatile UPS solution designed to meet the demanding needs of modern power systems. With options for 6 pulse or 12 pulse rectifiers and dual input support, this UPS ensures seamless operation across various voltage settings. Ideal for data centers, telecommunications, and industrial applications, the Giant iND II provides robust power protection and management.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePatented chassis structure offers 100%\u003c\/strong\u003e — Patented chassis structure offers 100% front access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation to prolong battery\u003c\/strong\u003e — Temperature compensation to prolong battery life\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackfeed protection and in-built 40kA\u003c\/strong\u003e — Backfeed protection and in-built 40kA surge protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7” colored LCD with customized\u003c\/strong\u003e — 7” colored LCD with customized control setting\u003c\/li\u003e\n\u003cli\u003eAccepts dual-mains inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel capability up to 4\u003c\/strong\u003e — Parallel capability up to 4 units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRectifier Type\u003c\/td\u003e\n\u003ctd\u003e6 pulse or 12 pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Input and Bypass Input\u003c\/td\u003e\n\u003ctd\u003eSupports dual inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e380VAC\/400VAC\/415VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceptable Voltage Range\u003c\/td\u003e\n\u003ctd\u003e304VAC ~ 456VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz ± 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTVSS\u003c\/td\u003e\n\u003ctd\u003e40kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e165VAC ~ 275VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e220VDC (Adjustable) \/ 384VDC (Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Start\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.8 \/ 0.9, customized up to 1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e220VAC\/230VAC\/240VAC \/ 380VAC\/400VAC\/415VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Capability\u003c\/td\u003e\n\u003ctd\u003e110% continuous running; 125% for 10 min; \u0026gt;150% for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDry Contacts\u003c\/td\u003e\n\u003ctd\u003e5 outputs and 4 inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional SNMP\u003c\/td\u003e\n\u003ctd\u003ePower management from SNMP manager and web browser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC62040-1-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Immunity\u003c\/td\u003e\n\u003ctd\u003eIEC61000-4-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Emissions\u003c\/td\u003e\n\u003ctd\u003eIEC62040-2-2018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE \/ CB\/ Conformance testing \/ EMC \/ ROHS2 \/ Reach \/ YDT1095-2018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection\u003c\/td\u003e\n\u003ctd\u003eIP31 (default), IP42 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, DxWxH (mm)\u003c\/td\u003e\n\u003ctd\u003e800 x 800 x 1800 \/ 800 x 1200 x 1800 \/ 800 x 1600 x 1800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (Kgs)\u003c\/td\u003e\n\u003ctd\u003e354 \/ 400 \/ 480 \/ 680 \/ 910 \/ 1010 \/ 1360 \/ 1620 \/ 285 \/ 319 \/ 337 \/ 387 \/ 468 \/ 523 \/ 349 \/ 385 \/ 427\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e354 \/ 400 \/ 480 \/ 680 \/ 910 \/ 1010 \/ 1360 \/ 1620 \/ 285 \/ 319 \/ 337 \/ 387 \/ 468 \/ 523 \/ 349 \/ 385 \/ 427\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0~ 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C ~ 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0~95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e1000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, CB, EMC, ROHS2, Reach, YDT1095-2018\u003c\/p\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the main performance specifications of the Giant iND II?\u003c\/summary\u003e\u003cp\u003eThe Giant iND II UPS features a power factor of 0.8 and supports nominal output voltages of 220VAC, 230VAC, and 240VAC with a regulation of ±1%. It operates at frequencies of 50Hz or 60Hz with an overload capability of 110% continuous running, 125% for 10 minutes, and over 150% for 1 minute.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the Giant iND II compatible with different battery types or solar panels?\u003c\/summary\u003e\u003cp\u003eThe Giant iND II is designed with flexibility in mind, featuring an adjustable battery voltage of 220VDC. However, it does not specifically mention compatibility with solar panels.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the physical specifications of the Giant iND II?\u003c\/summary\u003e\u003cp\u003eThe physical dimensions and weight of the Giant iND II are not specified in the provided information. For detailed physical specifications, please refer to the product manual or contact Voltronic Power directly.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the installation requirements for the Giant iND II?\u003c\/summary\u003e\u003cp\u003eThe Giant iND II requires a dual input setup for both the main and bypass inputs, supporting nominal voltages of 380VAC, 400VAC, and 415VAC. It is important to ensure the input voltage range is between 304VAC and 456VAC for optimal performance.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat warranty does the Giant iND II come with?\u003c\/summary\u003e\u003cp\u003eWarranty information is not specified in the provided details. It is recommended to check with the retailer or Voltronic Power for specific warranty terms and conditions.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat certifications and standards does the Giant iND II comply with?\u003c\/summary\u003e\u003cp\u003eThe Giant iND II complies with several certifications and standards including CE, CB, EMC, ROHS2, Reach, and YDT1095-2018, ensuring high safety and environmental standards.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the operating conditions for the Giant iND II?\u003c\/summary\u003e\u003cp\u003eThe specific operating temperature and humidity conditions are not detailed in the provided information. For precise operating conditions, please consult the product manual or contact Voltronic Power.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the key features and benefits of the Giant iND II?\u003c\/summary\u003e\u003cp\u003eKey features of the Giant iND II include its dual input support, high overload capability, and adjustable battery voltage. These features provide flexibility and reliability in various power environments.\u003c\/p\u003e\u003c\/details\u003e","brand":"Voltronic Power","offers":[{"title":"Default Title","offer_id":47936718700649,"sku":"VOLTRONIC-GIANT-IND-II","price":45000.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/giant_ind_ii_ds.jpg?v=1787309118","url":"https:\/\/www.solarinstaller.ae\/products\/giant-ind-ii-ds","provider":"Solar Installer","version":"1.0","type":"link"}