{"product_id":"galleonii-ds","title":"Voltronic Power Galleon II","description":"\u003cp\u003eIntroducing the Galleon II, Voltronic Power's advanced Online UPS designed to deliver exceptional power protection. With a wide range of nominal voltages and precise AC voltage regulation, it ensures reliable performance across various applications. The Galleon II is ideal for safeguarding sensitive electronics, data centers, and critical IT infrastructure, providing uninterrupted power and stability.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue double-conversion\u003c\/li\u003e\n\u003cli\u003eInput power factor correction 0.99\u003c\/li\u003e\n\u003cli\u003eOutput power factor 0.9\u003c\/li\u003e\n\u003cli\u003e50Hz\/60Hz frequency converter mode\u003c\/li\u003e\n\u003cli\u003eProgrammable power management outlets\u003c\/li\u003e\n\u003cli\u003eEmergency power off function (EPO)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECO mode operation for energy\u003c\/strong\u003e — ECO mode operation for energy saving\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVery high surge immunity up\u003c\/strong\u003e — Very high surge immunity up to 7KV, 13KA, 1300J\u003c\/li\u003e\n\u003cli\u003eGenerator compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh overload capability and enhanced\u003c\/strong\u003e — High overload capability and enhanced short circuit protection\u003c\/li\u003e\n\u003cli\u003eSNMP\/USB\/RS-232 multiple communications\u003c\/li\u003e\n\u003cli\u003e3-stage smart charging design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum 8A extended parallel control\u003c\/strong\u003e — Maximum 8A extended parallel control available for long run model\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional HID Power Device USB\u003c\/strong\u003e — Optional HID Power Device USB Port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLaser printer and ultrasound system\u003c\/strong\u003e — Laser printer and ultrasound system load acceptable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120\/127 VAC or 200\/208\/220\/230\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e55 - 150 VAC ± 5% or 110 - 300 VAC ± 5% @ 50% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e40 Hz ~ 70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e≥ 0.99 @ Nominal Voltage (100% Load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120\/127 VAC or 200\/208\/220\/230\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Regulation (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003e± 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Synchronized Range)\u003c\/td\u003e\n\u003ctd\u003e47 ~ 53 Hz or 57 ~ 63 Hz \/ 57 ~ 63 Hz or 47 ~ 53 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003e50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz \/ 60Hz ± 0.1Hz or 50 Hz ± 0.1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Crest Ratio\u003c\/td\u003e\n\u003ctd\u003e3:1 \/ 3:1 (max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Distortion\u003c\/td\u003e\n\u003ctd\u003e≤ 2 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003ePure Sinewave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Mode\u003c\/td\u003e\n\u003ctd\u003e90% \/ 91%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECO Mode\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e12 V \/ 7 Ah \/ 9 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumbers\u003c\/td\u003e\n\u003ctd\u003e3 \/ 6 \/ 8 \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e4 hours recover to 90% capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Current (max.)\u003c\/td\u003e\n\u003ctd\u003e1.5A \/ 1.2A \/ 1.5A*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Voltage\u003c\/td\u003e\n\u003ctd\u003e41.0 VDC ± 1% \/ 82.1 VDC ± 1% \/ 109.6 VDC ± 1% \/ 27.4 VDC ± 1%, 41.1 VDC ± 1% \/ 41.1 VDC ± 1% \/ 54.8 VDC ± 1%, 82.1 VDC ± 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart RS-232\/USB\u003c\/td\u003e\n\u003ctd\u003eSupports Windows® 2000\/2003\/XP\/Vista\/2008\/7\/8\/10, Linux and MAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension, D×W×H (mm)\u003c\/td\u003e\n\u003ctd\u003e397 × 145 × 220 \/ 421 × 190 × 318 \/ 410 × 438 × 88 \/ 510 × 438 × 88 \/ 630 × 438 × 88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kgs)\u003c\/td\u003e\n\u003ctd\u003e12.8 \/ 13.8 \/ 26.6 \/ 32.2 \/ 11.6 \/ 14.2 \/ 26.9 \/ 27.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e12.8 \/ 13.8 \/ 26.6 \/ 32.2 \/ 11.6 \/ 14.2 \/ 26.9 \/ 27.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e20-95 % RH @ 0- 40°C (Non-condensing) \/ 20-90 % RH @ 0- 40°C (Non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003eLess than 50dB @1Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the main performance specifications of the Galleon II?\u003c\/summary\u003e\u003cp\u003eThe Galleon II offers high efficiency with 90% in AC mode and 97% in ECO mode. It supports a nominal voltage range of 100\/110\/115\/120\/127 VAC or 200\/208\/220\/230\/240 VAC, and a power factor of ≥ 0.99 at nominal voltage with 100% load.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the Galleon II compatible with different battery types?\u003c\/summary\u003e\u003cp\u003eYes, the Galleon II uses a 12 V \/ 7 Ah battery type, making it compatible with standard UPS battery configurations.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the physical specifications of the Galleon II?\u003c\/summary\u003e\u003cp\u003eThe Galleon II's physical dimensions and weight are designed for easy installation, but specific details such as IP rating are not provided in the key specifications.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the installation requirements for the Galleon II?\u003c\/summary\u003e\u003cp\u003eInstallation requires a stable environment with a voltage range of 55 - 150 VAC or 110 - 300 VAC at 50% load. Ensure proper ventilation and adherence to safety standards.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat warranty is provided with the Galleon II?\u003c\/summary\u003e\u003cp\u003eThe Galleon II comes with a standard warranty, details of which can be obtained from the retailer or Voltronic Power's customer service.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat certifications and standards does the Galleon II meet?\u003c\/summary\u003e\u003cp\u003eThe Galleon II complies with standard certifications, ensuring reliability and safety in various operational environments.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the operating conditions for the Galleon II?\u003c\/summary\u003e\u003cp\u003eThe Galleon II operates efficiently within a frequency range of 40 Hz to 70 Hz and maintains performance in various temperature and humidity conditions.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the key features and benefits of the Galleon II?\u003c\/summary\u003e\u003cp\u003eKey features include zero transfer time, pure sinewave output in battery mode, and low harmonic distortion, making it ideal for sensitive electronic equipment.\u003c\/p\u003e\u003c\/details\u003e","brand":"Voltronic Power","offers":[{"title":"Default Title","offer_id":47936713588841,"sku":"VOLTRONIC-GALLEON-II","price":8000.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/galleonii_ds.jpg?v=1787309048","url":"https:\/\/www.solarinstaller.ae\/products\/galleonii-ds","provider":"Solar Installer","version":"1.0","type":"link"}