{"product_id":"galleon-iii-33-31-11-10kl-20kl-rt","title":"Voltronic Power Galleon III 33\/31\/11 10KL-20KL RT","description":"\u003cp\u003eThe Voltronic Power Galleon III 33\/31\/11 UPS is engineered for superior performance in demanding environments. With a nominal voltage of 3 x 380\/400\/415VAC or 220\/230\/240VAC, it ensures stable power delivery with precise voltage regulation in battery mode. Ideal for data centers, industrial applications, and critical infrastructure, the Galleon III 33\/31\/11 provides reliable power backup and protection.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue double-conversion\u003c\/li\u003e\n\u003cli\u003eRack\/Tower design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible system configuration as 3-in\/3-out,\u003c\/strong\u003e — Flexible system configuration as 3-in\/3-out, 3-in\/1-out or 1-in\/1-out\u003c\/li\u003e\n\u003cli\u003eDSP technology guarantees high performance\u003c\/li\u003e\n\u003cli\u003eOutput power factor 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive power factor correction in\u003c\/strong\u003e — Active power factor correction in all phases\u003c\/li\u003e\n\u003cli\u003e50Hz\/60Hz frequency converter mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECO mode operation for energy\u003c\/strong\u003e — ECO mode operation for energy saving (ECO)\u003c\/li\u003e\n\u003cli\u003eEmergency power off function (EPO)\u003c\/li\u003e\n\u003cli\u003eDual AC inputs\u003c\/li\u003e\n\u003cli\u003eGenerator compatible\u003c\/li\u003e\n\u003cli\u003eAdjustable battery numbers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel operation up to 4\u003c\/strong\u003e — Parallel operation up to 4 units with common battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e3 x 380\/400\/415VAC (3Ph+N) or 220\/230\/240VAC (1Ph+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e190-520 VAC (3-phase) @ 50% load; 305-478 VAC (3-phase) @ 100% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e46-54 Hz or 56-64 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 0.99 @ 100% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e3 x 380\/400\/415VAC (3Ph+N) or 220\/230\/240VAC (1Ph+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Regulation (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003e± 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Synchronized Range)\u003c\/td\u003e\n\u003ctd\u003e46-54Hz or 56-64Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003e50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Crest Ratio\u003c\/td\u003e\n\u003ctd\u003e3:1 (max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Distortion\u003c\/td\u003e\n\u003ctd\u003e≤ 2 % THD (Linear Load) ; ≤ 5 % THD (Non-linear Load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Mode\u003c\/td\u003e\n\u003ctd\u003e95.5% \/ 96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECO Mode\u003c\/td\u003e\n\u003ctd\u003e98.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eDepending on application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumbers\u003c\/td\u003e\n\u003ctd\u003e±8 ~ ±10 (adjustable) \/ ±16 ~ ±20 (adjustable) \/ ±10 ~ ±20 (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Current (max.)\u003c\/td\u003e\n\u003ctd\u003e1A ~ 18A (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Voltage (max.)\u003c\/td\u003e\n\u003ctd\u003e+\/ -13.65V DC x N (N=8~10) \/ +\/ -13.65V x N (N=16~20) \/ +\/ -13.65V x N (N=10~20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart RS-232\/USB\u003c\/td\u003e\n\u003ctd\u003eSupports Windows® Family, Linux and MAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional SNMP\u003c\/td\u003e\n\u003ctd\u003ePower management from SNMP manager and web browser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension, D X W X H (mm)\u003c\/td\u003e\n\u003ctd\u003e620 x 438 x 88 [2U] \/ 620 x 438 x 130.6 [3U]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kgs)\u003c\/td\u003e\n\u003ctd\u003e16 \/ 22.2 \/ 23.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e16 \/ 22.2 \/ 23.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd\u003e0-40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;95% and non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003eLess than 62dB @ 1 Meter \/ Less than 65dB @ 1 Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the main performance specifications of the Galleon III 33\/31\/11 UPS?\u003c\/summary\u003e\u003cp\u003eThe Galleon III 33\/31\/11 UPS offers high efficiency with AC mode at 95.5%, ECO mode at 98.5%, and battery mode at 94.5%. It supports a nominal voltage of 3 x 380\/400\/415VAC for three-phase or 220\/230\/240VAC for single-phase systems.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the Galleon III 33\/31\/11 compatible with different battery types or solar panels?\u003c\/summary\u003e\u003cp\u003eThe Galleon III 33\/31\/11 is designed to be compatible with a variety of battery types. However, it does not directly support solar panel integration without additional equipment.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the physical specifications of the Galleon III 33\/31\/11 UPS?\u003c\/summary\u003e\u003cp\u003eThe physical dimensions and weight of the Galleon III 33\/31\/11 UPS are not specified in the provided data. Please refer to the product manual for detailed information.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the installation requirements for the Galleon III 33\/31\/11?\u003c\/summary\u003e\u003cp\u003eInstallation of the Galleon III 33\/31\/11 requires a stable environment with proper ventilation. It should be installed by a qualified technician to ensure safety and compliance with local electrical standards.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat warranty is provided with the Galleon III 33\/31\/11 UPS?\u003c\/summary\u003e\u003cp\u003eThe Galleon III 33\/31\/11 UPS comes with a standard warranty, which typically covers manufacturing defects. For specific warranty terms, please consult the warranty documentation provided with the product.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat certifications and standards does the Galleon III 33\/31\/11 adhere to?\u003c\/summary\u003e\u003cp\u003eThe Galleon III 33\/31\/11 UPS complies with standard certifications, ensuring it meets industry safety and performance standards. Specific certifications are not listed in the provided data.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the operating conditions for the Galleon III 33\/31\/11?\u003c\/summary\u003e\u003cp\u003eThe Galleon III 33\/31\/11 UPS is designed to operate efficiently within a frequency range of 46-54 Hz or 56-64 Hz. It should be used in environments with controlled temperature and humidity levels.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the key features and benefits of the Galleon III 33\/31\/11 UPS?\u003c\/summary\u003e\u003cp\u003eKey features of the Galleon III 33\/31\/11 include zero transfer time, pure sine wave output in battery mode, and a high power factor of \u0026gt;= 0.99 at full load, ensuring reliable and efficient power supply.\u003c\/p\u003e\u003c\/details\u003e","brand":"Voltronic Power","offers":[{"title":"Default Title","offer_id":47936714506345,"sku":"VOLTRONIC-GALLEON-III-33-31-11-10KL-20KL-RT","price":30000.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/galleon_iii_33_31_11_10kl_20kl_rt.jpg?v=1787309062","url":"https:\/\/www.solarinstaller.ae\/products\/galleon-iii-33-31-11-10kl-20kl-rt","provider":"Solar Installer","version":"1.0","type":"link"}