{"product_id":"galleon-iii-33-30k","title":"Voltronic Power Galleon III 3P\/3P 30K","description":"\u003cp\u003eThe Voltronic Power Galleon III 3P\/3P 30-60KVA is a robust online UPS designed to deliver reliable power protection. With a nominal voltage of 3 x 380\/400\/415 VAC and precise AC voltage regulation of ±1%, it ensures optimal performance for critical applications. Ideal for data centers, industrial facilities, and telecommunications, the Galleon III provides seamless power continuity and protection against voltage fluctuations.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue double-conversion\u003c\/li\u003e\n\u003cli\u003eDSP technology guarantees high performance\u003c\/li\u003e\n\u003cli\u003eOutput power factor 1.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive power factor correction in\u003c\/strong\u003e — Active power factor correction in all phases\u003c\/li\u003e\n\u003cli\u003e50Hz\/60Hz frequency converter mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECO mode operation for energy\u003c\/strong\u003e — ECO mode operation for energy saving (ECO)\u003c\/li\u003e\n\u003cli\u003eEmergency power off function (EPO)\u003c\/li\u003e\n\u003cli\u003eGenerator compatible\u003c\/li\u003e\n\u003cli\u003eSNMP+USB+RS-232 multiple communications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-stage extendable charging design for\u003c\/strong\u003e — 3-stage extendable charging design for optimized battery performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable battery numbers for long-run\u003c\/strong\u003e — Adjustable battery numbers for long-run model\u003c\/li\u003e\n\u003cli\u003eMaintenance bypass available\u003c\/li\u003e\n\u003cli\u003eOptional parallel operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional isolation transformer offers full\u003c\/strong\u003e — Optional isolation transformer offers full isolation and complete common mode noise rejection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power (VA)\u003c\/td\u003e\n\u003ctd\u003e30kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power (W)\u003c\/td\u003e\n\u003ctd\u003e30kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e3 x 380\/400\/415 VAC (3Ph+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e190-520 VAC (3-phase) @ 50% load; 305-478 VAC (3-phase) @ 100% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e46-54 Hz or 56-64 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e≥ 0.99 @ 100% Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e3 x 380\/400\/415 VAC (3Ph+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Regulation\u003c\/td\u003e\n\u003ctd\u003e± 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Synchronized Range)\u003c\/td\u003e\n\u003ctd\u003e46-54Hz or 56-64Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003e50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Crest Ratio\u003c\/td\u003e\n\u003ctd\u003e3:1 (max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Distortion\u003c\/td\u003e\n\u003ctd\u003e≤ 2% THD (Linear Load) ; ≤ 5% THD (Non-linear Load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003ePure Sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Mode\u003c\/td\u003e\n\u003ctd\u003e95.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECO Mode\u003c\/td\u003e\n\u003ctd\u003e98.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e12V\/7Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumbers\u003c\/td\u003e\n\u003ctd\u003e(16+16)pcs x 2 strings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Current (max.)\u003c\/td\u003e\n\u003ctd\u003e2A (Default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Voltage\u003c\/td\u003e\n\u003ctd\u003e218 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart RS-232 \/ USB\u003c\/td\u003e\n\u003ctd\u003eSupports Windows® Family, Linux and MAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional SNMP\u003c\/td\u003e\n\u003ctd\u003ePower management from SNMP manager and web browser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension, DxWxH (mm)\u003c\/td\u003e\n\u003ctd\u003e815 x 300 x 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kgs)\u003c\/td\u003e\n\u003ctd\u003e207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-run Model Dimension, DxWxH (mm)\u003c\/td\u003e\n\u003ctd\u003e815 x 300 x 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-run Model Net Weight (kgs)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e207 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd\u003e0-40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 95% and non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003eLess than 65 dB @ 1 Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the main performance specifications of the Galleon III 3P\/3P 30-60KVA?\u003c\/summary\u003e\u003cp\u003eThe Galleon III offers high efficiency with AC mode at 95.5%, ECO mode at 98.5%, and battery mode at 94.5%. It supports a nominal voltage of 3 x 380\/400\/415 VAC and maintains a power factor of ≥ 0.99 at full load.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the Galleon III compatible with different battery types and solar panels?\u003c\/summary\u003e\u003cp\u003eThe Galleon III is designed to be compatible with a wide range of battery types. However, specific compatibility with solar panels should be verified with Voltronic Power or your installer.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the physical specifications of the Galleon III?\u003c\/summary\u003e\u003cp\u003eThe physical dimensions and weight of the Galleon III are not specified here. For detailed specifications, please refer to the product manual or contact Voltronic Power.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the installation requirements for the Galleon III?\u003c\/summary\u003e\u003cp\u003eInstallation of the Galleon III requires a 3-phase power supply and should be performed by a qualified technician to ensure proper setup and safety compliance.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat warranty does the Galleon III come with?\u003c\/summary\u003e\u003cp\u003eThe Galleon III typically comes with a standard warranty. For specific warranty terms and conditions, please consult the product documentation or contact Voltronic Power.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat certifications and standards does the Galleon III meet?\u003c\/summary\u003e\u003cp\u003eThe Galleon III meets standard certifications, ensuring compliance with industry regulations. For detailed certification information, refer to the product documentation.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the operating conditions for the Galleon III?\u003c\/summary\u003e\u003cp\u003eThe Galleon III is designed to operate efficiently within a specific temperature and humidity range. For precise operating conditions, please refer to the product manual.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the key features and benefits of the Galleon III?\u003c\/summary\u003e\u003cp\u003eKey features of the Galleon III include zero transfer time, pure sine wave output in battery mode, and low harmonic distortion, making it ideal for sensitive electronic equipment.\u003c\/p\u003e\u003c\/details\u003e","brand":"Voltronic Power","offers":[{"title":"Default Title","offer_id":47936714866793,"sku":"VOLTRONIC-GALLEON-III-3P3P-30K","price":75000.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/galleon_iii_33_30k_60k.jpg?v=1787309064","url":"https:\/\/www.solarinstaller.ae\/products\/galleon-iii-33-30k","provider":"Solar Installer","version":"1.0","type":"link"}