{"product_id":"galleon-ii-iii-33-10k-40k","title":"Voltronic Power Galleon II 3P\/3P 10-20KVA, III 3P\/3P 30-40KVA","description":"\u003cp\u003eVoltronic Power's Galleon II and III UPS systems are engineered for superior performance with 3P\/3P configurations ranging from 10KVA to 40KVA. These systems ensure reliable power with precise voltage regulation and adaptable frequency ranges, making them ideal for critical applications. The Galleon series is perfect for data centers, industrial operations, and sensitive electronic environments where consistent power supply is crucial.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue double-conversion\u003c\/li\u003e\n\u003cli\u003eDSP technology guarantees high performance\u003c\/li\u003e\n\u003cli\u003eOutput power factor 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive power factor correction in\u003c\/strong\u003e — Active power factor correction in all phases\u003c\/li\u003e\n\u003cli\u003e50Hz\/60Hz frequency converter mode\u003c\/li\u003e\n\u003cli\u003eDual AC inputs\u003c\/li\u003e\n\u003cli\u003eEmergency power off function (EPO)\u003c\/li\u003e\n\u003cli\u003eGenerator compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable battery numbers for long-run\u003c\/strong\u003e — Adjustable battery numbers for long-run model\u003c\/li\u003e\n\u003cli\u003eMaintenance bypass available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel operation up to 4\u003c\/strong\u003e — Parallel operation up to 4 units with common battery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional isolation transformer offers full\u003c\/strong\u003e — Optional isolation transformer offers full isolation and complete common mode noise rejection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e3 x 400 VAC (3Ph+N) \/ 230 VAC (1Ph+N) \/ 3 x 360\/380\/400\/415 VAC (3Ph+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e110-300 VAC ± 3 % @ 50% load; 176-276 VAC ± 3 % @ 100% load \/ 305VAC~457VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e46-54 Hz or 56-64Hz \/ 40-70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 0.99 @ 100% Load \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Distortion (THDi)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 4% at full linear load \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Regulation (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003e± 1% \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Synchronized Range)\u003c\/td\u003e\n\u003ctd\u003e46~54Hz or 56~64Hz \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003e50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz \/ 50\/60 Hz ± 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Crest Ratio\u003c\/td\u003e\n\u003ctd\u003e3:1 (max.) \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Distortion\u003c\/td\u003e\n\u003ctd\u003e≤ 2% THD (Linear Load) ; ≤ 5 % THD (Non-linear Load) \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003eZero \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003ePure Sine wave \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload AC Mode\u003c\/td\u003e\n\u003ctd\u003e100-110% for 60 min, 111-125% for 10 min, 126%-150% for 1 min; \u0026gt;150% immediately shutdown \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Mode\u003c\/td\u003e\n\u003ctd\u003e95.5% \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECO Mode\u003c\/td\u003e\n\u003ctd\u003e98.5% \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e12V\/9Ah \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumbers\u003c\/td\u003e\n\u003ctd\u003e(10+10) pcs \/ (16+16) pcs x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Model Recharge Time\u003c\/td\u003e\n\u003ctd\u003e9 hours recover to 90% capacity \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Current (max.)\u003c\/td\u003e\n\u003ctd\u003e1A (Default) \/ 2A (Default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/-136.5 VDC \/ +\/-218 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart RS-232 \/ USB\u003c\/td\u003e\n\u003ctd\u003eSupports Windows® Family, Linux and MAC \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional SNMP\u003c\/td\u003e\n\u003ctd\u003ePower management from SNMP manager and web browser \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Model Dimension, DxWxH (mm)\u003c\/td\u003e\n\u003ctd\u003e630 x 250 x 826 \/ 815 x 300 x 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kgs)\u003c\/td\u003e\n\u003ctd\u003e139 \/ 207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e139 \/ 207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd\u003e0-40°C \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 95% and non-condensing \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e0 – 1500m at full load \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the main performance specifications of the Galleon II and III UPS systems?\u003c\/summary\u003e\u003cp\u003eThe Galleon II and III UPS systems offer high efficiency with AC mode at 95.5% and ECO mode at 98.5%. They support a nominal voltage of 3 x 400 VAC and maintain a power factor greater than 0.99 at full load.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eAre these UPS systems compatible with different battery types or solar panels?\u003c\/summary\u003e\u003cp\u003eThe Galleon series is designed to be compatible with a wide range of battery types. However, specific compatibility with solar panels should be confirmed with Voltronic Power support.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the physical specifications of these UPS systems?\u003c\/summary\u003e\u003cp\u003eThe physical dimensions and weight vary depending on the model. For precise details, please refer to the product manual or contact Voltronic Power.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the installation requirements for the Galleon II and III UPS systems?\u003c\/summary\u003e\u003cp\u003eInstallation requires a stable environment with proper ventilation. Ensure the system is connected to a compatible power source and follow the installation guidelines provided in the manual.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat warranty is provided with the Galleon II and III UPS systems?\u003c\/summary\u003e\u003cp\u003eVoltronic Power typically offers a standard warranty period for their UPS systems. For specific warranty details, please consult the warranty documentation or contact customer support.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat certifications and standards do these UPS systems meet?\u003c\/summary\u003e\u003cp\u003eThe Galleon II and III UPS systems are certified to meet standard industry certifications, ensuring reliable performance and safety.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the operating conditions for these UPS systems?\u003c\/summary\u003e\u003cp\u003eThese UPS systems are designed to operate efficiently within a temperature range of 0°C to 40°C and a relative humidity of 0% to 95% non-condensing.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the key features and benefits of the Galleon II and III UPS systems?\u003c\/summary\u003e\u003cp\u003eKey features include zero transfer time, pure sine wave output in battery mode, and robust overload capabilities. These features ensure uninterrupted power supply and protection for sensitive equipment.\u003c\/p\u003e\u003c\/details\u003e","brand":"Voltronic Power","offers":[{"title":"Default Title","offer_id":47936713752681,"sku":"VOLTRONIC-GALLEON-II-III","price":35000.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/galleon_ii_iii_33_10k_40k.jpg?v=1787309051","url":"https:\/\/www.solarinstaller.ae\/products\/galleon-ii-iii-33-10k-40k","provider":"Solar Installer","version":"1.0","type":"link"}