{"product_id":"deye-sun-sg05lp1-eu","title":"Deye 3.6–8 kW Single-Phase Low-Voltage Hybrid Solar Inverter","description":"\u003cp\u003eThe SG05LP1 is Deye's single-phase hybrid inverter for a house with a 48 V battery: it runs the panels, charges the bank and keeps the lights on when the grid drops, all from one wall box. Six ratings cover 3.6 kW to 8 kW, and what separates them is how fast they charge and how many panels they will take. Every one of them works with lead-acid or lithium banks between 40 V and 60 V.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo MPPT trackers over a 150 V to 425 V window, 500 V maximum panel voltage\u003c\/li\u003e\n\u003cli\u003eTakes a 40 V to 60 V lead-acid or lithium bank, and up to 16 units run in parallel\u003c\/li\u003e\n\u003cli\u003e97.6% peak efficiency, 96.5% on the European weighted scale, twice rated power for 10 s\u003c\/li\u003e\n\u003cli\u003eIP65 case, fan cooling measured at 30 dB, colour touch screen, 24.9 kg on the wall\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3.6 kW hybrid inverter for a small home, 90 A battery charge rate\u003c\/h3\u003e\u003cp\u003eThe smallest of the six. It charges and discharges the battery at up to 90 A, takes 5,760 W of panel input with 7,200 W of array allowed, and passes 35 A of grid current through to the house. Rated output is 16.4 A, or 3,960 VA at peak. A fit for a flat or a two-bedroom house where the evening load is lights, a fridge and a room or two of cooling.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery charge and discharge: 90 A · Max PV input power: 5,760 W · Grid passthrough: 35 A · Rated output current: 16.4 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3.6K-SG05LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5 kW single-phase hybrid inverter with 120 A charging for a villa\u003c\/h3\u003e\u003cp\u003eThe size most homes settle on. Charge and discharge climb to 120 A, a third more than the 3.6 kW, so a bank refills noticeably faster on a short sunny window. It takes 8,000 W of panels with 10,000 W of array allowed and puts out 22.7 A. Grid passthrough is still 35 A, the same as the 3.6 kW, so the incoming supply usually needs no change.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery charge and discharge: 120 A · Max PV input power: 8,000 W · Grid passthrough: 35 A · Rated output current: 22.7 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-SG05LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW hybrid solar inverter, 135 A charging and 40 A grid passthrough\u003c\/h3\u003e\u003cp\u003eThe first model in the range with 40 A of grid passthrough rather than 35 A, which matters when the whole house sits behind the inverter instead of a small backup board. Battery current rises to 135 A and panel input to 9,600 W, with 12,000 W of array permitted. Rated output is 27.3 A at 6,600 VA. Good for a four-bedroom house with two or three air conditioners.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery charge and discharge: 135 A · Max PV input power: 9,600 W · Grid passthrough: 40 A · Rated output current: 27.3 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-SG05LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7 kW hybrid inverter with doubled 26 A panel input and 175 A charging\u003c\/h3\u003e\u003cp\u003eFrom 7 kW upward the DC side is doubled: 26 A of panel input current and 34 A of short-circuit current, against 13 A and 17 A on the 3.6 kW to 6 kW models, so more strings land on the same unit. Battery current is 175 A and panel input 11,200 W, with 14,000 W of array allowed. Rated output is 31.9 A at 7,700 VA.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery charge and discharge: 175 A · Max PV input power: 11,200 W · Max PV input current: 26 A · Rated output current: 31.9 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7K-SG05LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7.6 kW single-phase hybrid inverter with 50 A of grid passthrough\u003c\/h3\u003e\u003cp\u003eThe 7.6 kW raises grid passthrough to 50 A, ten more than the 7 kW, and takes battery current to 190 A. Panel input is 12,160 W with 15,200 W of array allowed, and rated output is 34.5 A at 8,360 VA. The 0.6 kW gap over the 7 kW is small, so decide between the two on the passthrough figure and on what the main breaker will carry.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery charge and discharge: 190 A · Max PV input power: 12,160 W · Grid passthrough: 50 A · Rated output current: 34.5 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7.6K-SG05LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW single-phase hybrid inverter, the largest of the six ratings here\u003c\/h3\u003e\u003cp\u003eThe top of the range. Battery current is 190 A, the same as the 7.6 kW, so the two differ on the solar and output side: 12,800 W of panel input against 12,160 W, 16,000 W of array allowed, and 36.4 A of rated output at 8,800 VA. Take this one because the roof is already full and you want every panel working, not because you need faster charging.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery charge and discharge: 190 A · Max PV input power: 12,800 W · Max PV array power: 16,000 W · Rated output current: 36.4 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-SG05LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 6 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLead-acid or Lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e40-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eWIFI,RS485,CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e96.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003eL+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IECOVE-Richtlinie62116,CEI0-21,R25,ENG98,50549,G99,NRSVDE-AR-N097,RD4105140, UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eColorful Touch LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/230 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e2 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e125-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-40 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e24.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e330 x 580 x 232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"3.6 kW","offer_id":47869740744809,"sku":"SUN-3.6K-SG05LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true},{"title":"5 kW","offer_id":47869740777577,"sku":"SUN-5K-SG05LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869740810345,"sku":"SUN-6K-SG05LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true},{"title":"7 kW","offer_id":47869740843113,"sku":"SUN-7K-SG05LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true},{"title":"7.6 kW","offer_id":47869740875881,"sku":"SUN-7.6K-SG05LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869740908649,"sku":"SUN-8K-SG05LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-3.6-10K-SG05LP1.png?v=1785851391","url":"https:\/\/www.solarinstaller.ae\/products\/deye-sun-sg05lp1-eu","provider":"Solar Installer","version":"1.0","type":"link"}