{"product_id":"deye-sun-sg02lp2-us-am2","title":"Deye 5–8 kW Split-Phase Low-Voltage Hybrid Solar Inverter (SUN-SG02LP2-US-AM2)","description":"\u003cp\u003eThe SUN-SG02LP2-US-AM2 is a split-phase hybrid inverter, which means it puts out 120 V and 240 V at the same time on a two-line supply with neutral, rather than the single 230 V used across Europe and the Gulf. Four sizes cover 5 kW to 8 kW. All of them charge a 48 V battery, all accept a diesel generator as a second source, and up to sixteen can be paralleled on one site.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutput is 120\/240 V split phase, with 208 V also supported, and each unit weighs 35.6 kg.\u003c\/li\u003e\n\u003cli\u003e97.6% peak efficiency and 96.5% on the European weighted measure, with two trackers working from 150 to 425 V.\u003c\/li\u003e\n\u003cli\u003eThe case is sealed to IP65, the unit is quiet at 45 dB, and it is specified from -40 to 60 C and up to 2,000 m.\u003c\/li\u003e\n\u003cli\u003eSixteen units run in parallel, and every size takes a generator input as well as the grid.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e5 kW split-phase hybrid inverter for a 120\/240 V home with a 48 V bank\u003c\/h3\u003e\u003cp\u003eThe smallest of the four. It carries 7,500 W of panels, 5,000 VA of output and 20.9 A per leg, and charges the battery at up to 120 A. Grid passthrough to the loads is 35 A, the lowest in this group, so check the main breaker feeding the house before settling on it. Full load tracking runs from 300 to 425 V, the same window as the 6 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 120 A · Max PV input power: 7,500 W · Max AC output current: 20.9 A · Grid passthrough: 35 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-SG02LP2-US-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW split-phase hybrid inverter for a house with two air conditioners\u003c\/h3\u003e\u003cp\u003eOne step up, and much of the step is in what passes through. Output is 6,000 VA at 25 A per leg, charging rises to 135 A, and grid passthrough to the loads goes from 35 A to 40 A. The array can reach 9,000 W. Tracking at full load uses the same 300 to 425 V window as the 5 kW, so a string layout drawn for that model carries over unchanged.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 135 A · Max PV input power: 9,000 W · Max AC output current: 25 A · Grid passthrough: 40 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-SG02LP2-US-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7.6 kW split-phase hybrid inverter, the size between 6 kW and 8 kW\u003c\/h3\u003e\u003cp\u003eThe 7.6 kW and the 8 kW are close relatives: both charge at 190 A, both pass 50 A of grid current through to the loads and both accept 26 A per tracker. What separates them is output, 7,600 VA and 31.7 A per leg here against 8,000 VA and 33.4 A, and array size, 11,400 W against 12,000 W. Full load tracking drops to a 200 V floor on both.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 190 A · Max PV input power: 11,400 W · Max AC output current: 31.7 A · Grid passthrough: 50 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7.6K-SG02LP2-US-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW split-phase hybrid inverter for a large home or a small business\u003c\/h3\u003e\u003cp\u003eThe largest of the four, and the one to pick if the roof is already drawn. It takes 12,000 W of panels and gives 8,000 VA at 33.4 A per leg, charging the battery at 190 A with 50 A of grid passthrough. Because it shares the charger and the 200 to 425 V full load window with the 7.6 kW, what you actually gain is 400 VA of output and 600 W of array.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 190 A · Max PV input power: 12,000 W · Max AC output current: 33.4 A · Grid passthrough: 50 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-SG02LP2-US-AM2\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 4 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e120\/240V; 208V 0.88Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e60Hz\/55Hz-65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e125-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLead-acid or Lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e40-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e2L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Hz)\u003c\/td\u003e\n\u003ctd\u003e60Hz\/55Hz-65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e2 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS232, RS485, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEEE 1547.1,SRD V2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC IV(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eFCC,UL 1741\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e96.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e120\/240V, 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-40 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e35.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e420 x 670 x 233\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e2L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"5 kW","offer_id":47869741432937,"sku":"SUN-5K-SG02LP2-US-AM2","price":4400.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869741465705,"sku":"SUN-6K-SG02LP2-US-AM2","price":4400.0,"currency_code":"AED","in_stock":true},{"title":"7.6 kW","offer_id":47869741498473,"sku":"SUN-7.6K-SG02LP2-US-AM2","price":4400.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869741531241,"sku":"SUN-8K-SG02LP2-US-AM2","price":4400.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-5-8K-SG02LP2-US.png?v=1785851399","url":"https:\/\/www.solarinstaller.ae\/products\/deye-sun-sg02lp2-us-am2","provider":"Solar Installer","version":"1.0","type":"link"}