{"product_id":"deye-sun-sg02hp3-eu-em6","title":"Deye 60–80 kW Three-Phase High-Voltage Hybrid Solar Inverter","description":"\u003cp\u003eThe SUN SG02HP3 is Deye's largest three-phase hybrid inverter, built for a factory, a cold store or a hotel that wants to run on solar by day and stored power into the evening. All four ratings take high-voltage lithium batteries between 160 V and 1000 V across two separate battery inputs, and any of them will pass 200 A of grid supply straight through to the loads. What separates them is how much panel they will accept and how much current they can push back out.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo battery inputs, each charging and discharging at up to 80 A, so storage can be added in two banks rather than one\u003c\/li\u003e\n\u003cli\u003eSix MPPT trackers per unit and up to 10 units in parallel, enough scope for a roof broken into several sections\u003c\/li\u003e\n\u003cli\u003e200 A of grid supply passes straight through to the loads, and the whole rating can sit on one phase if the site is unbalanced\u003c\/li\u003e\n\u003cli\u003eThe same 105 kg cabinet on every rating, IP65 sealed and rated from -40°C to 60°C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e60 kW three-phase hybrid inverter for a factory on 120 kW of panels\u003c\/h3\u003e\u003cp\u003eThe entry point of the range, and the one that copes best with a low-voltage array: it holds full output from 365 V upward, where the 80 kW wants 485 V. You can wire 120 kW of panels to it, of which 96 kW converts at any one moment, which leaves room for east and west pitches on a single machine. Rated output is 91 A per phase, peaking at 100 A and 66 kVA.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels connectable: 120 kW · Usable PV input: 96 kW · Rated current per phase: 91 A · Full-output PV window: 365-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-60K-SG02HP3-EU-EM6\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e70 kW three-phase hybrid solar inverter with 112 kW of usable PV\u003c\/h3\u003e\u003cp\u003eA 70 kW rating for sites whose supply agreement lands between the 60 and 75 kW models. It accepts 140 kW of panels with 112 kW usable at once, and delivers 106.1 A per phase, climbing to 116.7 A and 77 kVA at the ceiling. The array has to reach 425 V before it will hold full output, so strings run a little longer than they would on the 60 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels connectable: 140 kW · Usable PV input: 112 kW · Rated current per phase: 106.1 A · Full-output PV window: 425-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-70K-SG02HP3-EU-EM6\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e75 kW three-phase hybrid inverter for a large commercial rooftop\u003c\/h3\u003e\u003cp\u003eThis sits between the 70 and 80 kW models and is the usual pick when a 150 kW array is already on the roof, since 120 kW of that reaches the inverter at any one time. Output runs at 113.7 A per phase and rises to 125 A, with 82.5 kVA of apparent power for motor starting and similar surges. Full output begins once the strings clear 455 V.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels connectable: 150 kW · Usable PV input: 120 kW · Rated current per phase: 113.7 A · Full-output PV window: 455-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-75K-SG02HP3-EU-EM6\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e80 kW three-phase hybrid inverter, the biggest in the SG02HP3 line\u003c\/h3\u003e\u003cp\u003eThe largest of the four accepts 160 kW of panels with 128 kW converted at once, and pushes 121.3 A per phase, peaking at 133.4 A and 88 kVA. It also asks the most of the array, holding rated output only from 485 V upward, so strings need to be long enough to stay above that on a dull morning. Ten of these in parallel bring a site to 800 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels connectable: 160 kW · Usable PV input: 128 kW · Rated current per phase: 121.3 A · Full-output PV window: 485-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-80K-SG02HP3-EU-EM6\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 4 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charge Current (A)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charge Discharge Current (A)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e160-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\/CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Passthrough (A)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Discharge Current (A)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalanced Output (%)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Input Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e180-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Fault Current (A)\u003c\/td\u003e\n\u003ctd\u003e256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Ocp (A)\u003c\/td\u003e\n\u003ctd\u003e334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Reverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-40 to +60℃, \u0026gt;45℃ Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e606 x 927 x 314\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eCharging Strategy for Li-ion Battery: Self-adaption to BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"60 kW","offer_id":47869741793385,"sku":"SUN-60K-SG02HP3-EU-EM6","price":44000.0,"currency_code":"AED","in_stock":true},{"title":"70 kW","offer_id":47869741826153,"sku":"SUN-70K-SG02HP3-EU-EM6","price":44000.0,"currency_code":"AED","in_stock":true},{"title":"75 kW","offer_id":47869741858921,"sku":"SUN-75K-SG02HP3-EU-EM6","price":44000.0,"currency_code":"AED","in_stock":true},{"title":"80 kW","offer_id":47869741891689,"sku":"SUN-80K-SG02HP3-EU-EM6","price":44000.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-60-80K-SG02HP3.png?v=1785851405","url":"https:\/\/www.solarinstaller.ae\/products\/deye-sun-sg02hp3-eu-em6","provider":"Solar Installer","version":"1.0","type":"link"}