{"product_id":"deye-sun-sg01hp3-eu-bm3","title":"Deye 29.9–35 kW Three-Phase High-Voltage Hybrid Solar Inverter","description":"\u003cp\u003eThe SG01HP3 is Deye's three-phase hybrid inverter for commercial roofs, farms and workshops, built around a high-voltage battery rather than a 48 V one. Three ratings are offered, 29.9 kW, 30 kW and 35 kW, and all of them charge and discharge at 100 A across two battery inputs. Ten units can be wired in parallel when one is not enough.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRuns a high-voltage battery from 160 V to 800 V, on two inputs of 50 A each\u003c\/li\u003e\n\u003cli\u003ePasses 200 A of grid current through to the loads, and holds 1.5 times rated power for 10 seconds off-grid\u003c\/li\u003e\n\u003cli\u003eTen units in parallel, with 100% unbalanced output so a single phase can carry the whole load\u003c\/li\u003e\n\u003cli\u003e80 kg IP65 cabinet, air-cooled, rated from -40 to +60 C and up to 2000 m altitude\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e29.9 kW three-phase hybrid inverter capped at 29,900 VA for grid rules\u003c\/h3\u003e\u003cp\u003eThe 29.9 kW exists for one reason: many grid operators cap a connection at 30 kVA, and this model's apparent output is held to exactly 29,900 VA instead of being oversized above its rating. It takes 59,800 W of panels, 38,870 W of DC input power, and puts out 45.4 A per phase. If the utility paperwork carries a 30 kVA limit, this is the version that clears it without an argument.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eApparent power: 29,900 VA · Max panel array: 59,800 W · Max AC output current: 45.4 A · Max DC input power: 38,870 W\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-29.9K-SG01HP3-EU-BM3\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e30 kW three-phase high-voltage hybrid inverter, 33 kVA apparent output\u003c\/h3\u003e\u003cp\u003eSame 30 kW class, but the apparent output runs to 33,000 VA, so it can push 50 A per phase when the sun is strong and the battery is helping. Panel capacity is 60,000 W with 39,000 W of DC input. Choose it over the 29.9 kW anywhere the grid connection is not capped, since the extra 3,100 VA of headroom comes in the same 80 kg cabinet at the same size.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eApparent power: 33,000 VA · Max panel array: 60,000 W · Max AC output current: 50 A · Max DC input power: 39,000 W\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-30K-SG01HP3-EU-BM3\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e35 kW three-phase hybrid solar inverter for a 70 kW panel array\u003c\/h3\u003e\u003cp\u003eThe biggest of the three, at 38,500 VA and 58.4 A per phase, fed by as much as 70,000 W of panels and 45,500 W of DC input. One point to watch in the string design: at full load its tracking window starts at 420 V rather than the 360 V of the two smaller models, so strings need a few more modules to hold rated output. The cabinet is unchanged at 80 kg.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eApparent power: 38,500 VA · Max panel array: 70,000 W · Max AC output current: 58.4 A · Max DC input power: 45,500 W\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-35K-SG01HP3-EU-BM3\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 3 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charge Discharge Current (A)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Over Current Protection (A)\u003c\/td\u003e\n\u003ctd\u003e144.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e3\/2+2+2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e180-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e160-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eWIFI, RS485, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charge Current (A)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Passthrough (A)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Discharge Current (A)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e1.5 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalanced Output (%)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-40 to +60℃, \u0026gt;45℃ Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e527 x 894 x 294\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"29.9 kW","offer_id":47869740154985,"sku":"SUN-29.9K-SG01HP3-EU-BM3","price":16844.0,"currency_code":"AED","in_stock":true},{"title":"30 kW","offer_id":47869740187753,"sku":"SUN-30K-SG01HP3-EU-BM3","price":16844.0,"currency_code":"AED","in_stock":true},{"title":"35 kW","offer_id":47869740220521,"sku":"SUN-35K-SG01HP3-EU-BM3","price":16844.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-29.9-35K-SG01HP3.png?v=1785851382","url":"https:\/\/www.solarinstaller.ae\/products\/deye-sun-sg01hp3-eu-bm3","provider":"Solar Installer","version":"1.0","type":"link"}