{"product_id":"deye-sun-g04-p3","title":"Deye 30–50 kW Three-Phase Solar Inverter","description":"\u003cp\u003eThe Deye G04 three-phase solar inverter is a grid-tied machine for commercial roofs: it turns panel output into 400 V three-phase power and feeds it straight into the building, with no battery involved. Seven ratings run from 30 kW to 50 kW, and the practical difference between them is how much panel each one can take and how many separate roof faces it can track independently.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEuropean weighted efficiency of 98.1% on every rating in the group\u003c\/li\u003e\n\u003cli\u003eStrings up to 1,100 V, tracked anywhere between 200 V and 1,000 V\u003c\/li\u003e\n\u003cli\u003eStarts producing from 250 V and holds current distortion below 3%\u003c\/li\u003e\n\u003cli\u003eIP65 enclosure rated from -25 C to 60 C for rooftop or plant-room mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e30 kW three-phase grid-tied solar inverter for a 45 kW commercial roof\u003c\/h3\u003e\u003cp\u003eThe entry point of the G04 line takes up to 45 kW of panel against a 30 kW output, a 1.5 times oversize that only the 36 kW model matches. Two independent inputs of 40 A each let you split the array across two roof faces. It puts out 33 kVA and 50 A per phase, peaks at 98.6% efficiency, and weighs 23 kg.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 45 kW · PV inputs: 2 x 40 A · Max AC output current: 50 A · Weight: 23 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-30K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e33 kW three-phase solar inverter, 42.9 kW panel input, two trackers\u003c\/h3\u003e\u003cp\u003eThe 33 kW and the 35 kW share a datasheet column, so their output currents are quoted together rather than separately. What clearly separates them is the array: this one is specified for 42.9 kW of panel, 2.6 kW less than the 35 kW. Two 40 A inputs, full output from 500 V upward, 98.6% peak efficiency, and an altitude rating of 4,000 m for highland sites.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 42.9 kW · PV inputs: 2 x 40 A · Full-load tracking window: 500 to 850 V · Max altitude: 4,000 m\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-33K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e35 kW three-phase solar inverter with 45.5 kW of panel input allowed\u003c\/h3\u003e\u003cp\u003eTwo extra kilowatts of output over the 33 kW, and 45.5 kW of panel rather than 42.9 kW. Deye publishes one shared current column for the two models, so we do not quote a separate output current here; the honest difference is rated power and array size. A 23 kg wall case, a pair of 40 A inputs, a 4,000 m altitude rating and 98.6% peak efficiency.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 45.5 kW · PV inputs: 2 x 40 A · Weight: 23 kg · Max efficiency: 98.6%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-35K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e36 kW three-phase solar inverter, 54 kW panel input on two trackers\u003c\/h3\u003e\u003cp\u003eThis is the last of the two-tracker frames and carries the most panel of that group: 54 kW feeding a 36 kW output. Useful on east and west roofs where neither side peaks at once. It delivers 39.6 kVA and 60 A per phase from a 23 kg case, and holds full output from 500 V upward. Fault current is quoted at 104.4 A, which your protection device needs to clear.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 54 kW · Max apparent power: 39.6 kVA · Max AC output current: 60 A · PV inputs: 2 x 40 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-36K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e40 kW three-phase solar inverter with three MPP trackers, 98.7% peak\u003c\/h3\u003e\u003cp\u003eA third independent PV input arrives at 40 kW, so the array can be split three ways across roofs facing different directions without losing yield on the shaded one. Peak efficiency also rises to 98.7%. Output is 44 kVA and 66.7 A per phase, panel input is capped at 52 kW, and the unit runs under 50 dB, quiet enough for a plant room next to offices. It weighs 37.1 kg.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 52 kW · PV inputs: 3 x 40 A · Max AC output current: 66.7 A · Noise: under 50 dB\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-40K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e45 kW three-phase solar inverter, 58.5 kW panel, three MPP trackers\u003c\/h3\u003e\u003cp\u003eThree 40 A inputs again, but a much larger frame: 698 by 613 by 236.5 mm and 53.7 kg, the same weight as the 33 kW. It accepts 58.5 kW of panel, gives 49.5 kVA and 75 A per phase, and holds 98.7% peak efficiency. Check the wall or frame it goes on before ordering, because the extra 16.6 kg over the 40 kW changes the fixing.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 58.5 kW · PV inputs: 3 x 40 A · Max AC output current: 75 A · Weight: 53.7 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-45K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e50 kW three-phase solar inverter with four MPP trackers, 65 kW panel\u003c\/h3\u003e\u003cp\u003eThe largest rating is the only one with four separate 40 A PV inputs, which suits a site with several roof pitches or a car park canopy in sections. It takes 65 kW of panel, the most in the range, and returns 55 kVA and 83.3 A per phase at up to 98.7% efficiency. Fault current is 145 A, so size the AC protection and cable accordingly.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 65 kW · PV inputs: 4 x 40 A · Max AC output current: 83.3 A · Max apparent power: 55 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-50K-G04\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 7 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIECUNE61727,217002,IEC62116,OVE-RichtlinieCEI0-21, ENR25,50549,G99,VDE-AR-NNRS097,RD4105140,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC),OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC),TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"30 kW","offer_id":47869740941417,"sku":"DEYE-SUN-30K-G04","price":3963.0,"currency_code":"AED","in_stock":true},{"title":"33 kW","offer_id":47869740974185,"sku":"DEYE-SUN-33K-G04","price":3963.0,"currency_code":"AED","in_stock":true},{"title":"35 kW","offer_id":47869741006953,"sku":"DEYE-SUN-35K-G04","price":3963.0,"currency_code":"AED","in_stock":true},{"title":"36 kW","offer_id":47869741039721,"sku":"DEYE-SUN-36K-G04","price":3963.0,"currency_code":"AED","in_stock":true},{"title":"40 kW","offer_id":47869741072489,"sku":"DEYE-SUN-40K-G04","price":5689.0,"currency_code":"AED","in_stock":true},{"title":"45 kW","offer_id":47869741105257,"sku":"DEYE-SUN-45K-G04","price":5689.0,"currency_code":"AED","in_stock":true},{"title":"50 kW","offer_id":47869741138025,"sku":"DEYE-SUN-50K-G04","price":5689.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-30-36K-G04.png?v=1785851393","url":"https:\/\/www.solarinstaller.ae\/products\/deye-sun-g04-p3","provider":"Solar Installer","version":"1.0","type":"link"}