{"product_id":"deye-sun-g01p3-eu-am8","title":"Deye 120–136 kW Three-Phase Solar Inverter","description":"\u003cp\u003eThis is the largest three-phase solar inverter Deye builds for rooftops and ground mounts that need real capacity: five ratings from 120 kW up to 136 kW, all on the same 103 kg chassis. Eight separate tracker inputs let you run strings at different angles or on different roof faces without one shaded string pulling the rest down. Every unit is sealed to IP65 and keeps working to 60°C ambient, with output derating above 45°C.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEight MPPT tracker inputs, each taking up to 40 A, so strings on different roof faces are handled separately.\u003c\/li\u003e\n\u003cli\u003e98.8% peak efficiency and 98.2% European efficiency across the whole range.\u003c\/li\u003e\n\u003cli\u003eIP65 sealed with intelligent air cooling, rated from -25°C to 60°C and up to 4,000 m altitude.\u003c\/li\u003e\n\u003cli\u003eThe same 1006 x 516 x 325.5 mm body at 103 kg, so mounting hardware is identical whichever rating you pick.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e120 kW three-phase inverter for large commercial rooftops and sheds\u003c\/h3\u003e\u003cp\u003eThe 120 kW is the only unit here rated at 132 kVA, and its 200 A maximum output current is the lowest in the range, which usually means a smaller AC cable and a cheaper breaker. Rated output current sits at 181.9 A. It accepts up to 180 kW of panels, so a 1.5 ratio of array to inverter still fits. Pick it when the grid connection caps you near 120 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 120 kW · Max apparent power: 132 kVA · Max AC output current: 200 A · Max PV input: 180 kW\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-120K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e125 kW three-phase string inverter, a small step up on the same frame\u003c\/h3\u003e\u003cp\u003eAt 125 kW the apparent power climbs to 135 kVA and rated output current to 189.4 A, while the panel ceiling rises to 187.5 kW. That extra 7.5 kW of array headroom over the 120 kW unit is the practical reason to choose it: you fit two or three more strings without buying a second inverter. Cabling, mounting frame and enclosure stay exactly the same.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 125 kW · Max apparent power: 135 kVA · Rated output current: 189.4 A · Max PV input: 187.5 kW\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-125K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e130 kW three-phase inverter for a 195 kW array on one connection\u003c\/h3\u003e\u003cp\u003eThe 130 kW takes up to 195 kW of panels and runs a rated output current of 197 A. Its 204.6 A maximum output current and 135 kVA apparent power are shared with the 125 kW and 135 kW units, so the real gain is 7.5 kW more array than the 125 kW model on identical AC hardware. That suits a site where roof space is the limit rather than the grid connection.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 130 kW · Rated output current: 197 A · Max PV input: 195 kW · Max apparent power: 135 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-130K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e135 kW three-phase inverter that runs at its own current ceiling\u003c\/h3\u003e\u003cp\u003eAt 135 kW the rated output current and the maximum output current are the same number, 204.6 A, so the unit works at the top of its 135 kVA rating continuously instead of holding a reserve. Panel input goes to 202.5 kW. Size the AC breaker and cable for 204.6 A on this model, not for a lower rated figure, because on this one the two values are identical.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 135 kW · Rated output current: 204.6 A · Max PV input: 202.5 kW · Max apparent power: 135 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-135K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e136 kW three-phase inverter, the largest rating in the AM8 range\u003c\/h3\u003e\u003cp\u003eThe 136 kW sits at the top of the family and is the only one rated 136 kVA, with rated and maximum output current both at 206.1 A. It carries up to 204 kW of panels, the largest array allowance here. Choose it when your grid connection can take 206.1 A per phase and you want every kilowatt the chassis offers. The 135 kW model gives up 1.5 kW of array for almost the same current.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 136 kW · Max apparent power: 136 kVA · Max AC output current: 206.1 A · Max PV input: 204 kW\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-136K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 5 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Injection (%)\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Full Load Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e550-850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e8\/4+4+4+4+4+4+4+4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Ocp (A)\u003c\/td\u003e\n\u003ctd\u003e398\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232 \/WiFi\/LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e1006 x 516 x 325.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"120 kW","offer_id":47869739466857,"sku":"SUN-120K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true},{"title":"125 kW","offer_id":47869739499625,"sku":"SUN-125K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true},{"title":"130 kW","offer_id":47869739532393,"sku":"SUN-130K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true},{"title":"135 kW","offer_id":47869739565161,"sku":"SUN-135K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true},{"title":"136 kW","offer_id":47869739597929,"sku":"SUN-136K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-120-136K-G01P3.png?v=1785851372","url":"https:\/\/www.solarinstaller.ae\/products\/deye-sun-g01p3-eu-am8","provider":"Solar Installer","version":"1.0","type":"link"}