{"product_id":"axpert-max-ii-twin-8-12kw-11000va-11000w","title":"Voltronic Power Axpert MAX II TWIN 11K","description":"\u003cp\u003eThe Voltronic Power Axpert MAX II TWIN inverter is engineered for high performance with a rated power of 11000VA\/11000W. It ensures stable energy output with 230VAC ± 5% regulation in battery mode, making it a reliable choice for various applications. Ideal for residential and commercial use, the Axpert MAX II TWIN is perfect for backup power systems, solar energy setups, and off-grid applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIncreased PV power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTouchable button with 5\" color\u003c\/strong\u003e — Touchable button with 5\" color LCD\u003c\/li\u003e\n\u003cli\u003eStatus indication with RGB lights\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual outputs for smart load\u003c\/strong\u003e — Dual outputs for smart load management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpgrade maximum PV current to\u003c\/strong\u003e — Upgrade maximum PV current to 60A for 12K model\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in WiFi with APP for\u003c\/strong\u003e — Built-in WiFi with APP for mobile monitoring and OTA firmware upgrade\u003c\/li\u003e\n\u003cli\u003eSupports USB On-the-Go function\u003c\/li\u003e\n\u003cli\u003eBuilt-in BMS communication port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in meter calibration for optimized\u003c\/strong\u003e — Built-in meter calibration for optimized system operation\u003c\/li\u003e\n\u003cli\u003eBattery independent design\u003c\/li\u003e\n\u003cli\u003eBuilt-in anti-dust kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in DC output for DC\u003c\/strong\u003e — Built-in DC output for DC fan, LED bulb, router and so on\u003c\/li\u003e\n\u003cli\u003eParallel operation with 6 units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency (Line Mode)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;95% (Rated R load, battery full charged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Loss Frequency\u003c\/td\u003e\n\u003ctd\u003e65±1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Loss Return Frequency\u003c\/td\u003e\n\u003ctd\u003e63±1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Loss Return Voltage\u003c\/td\u003e\n\u003ctd\u003e270Vac±7V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Loss Voltage\u003c\/td\u003e\n\u003ctd\u003e280Vac±7V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Loss Frequency\u003c\/td\u003e\n\u003ctd\u003e40±1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Loss Return Frequency\u003c\/td\u003e\n\u003ctd\u003e42±1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Loss Return Voltage\u003c\/td\u003e\n\u003ctd\u003e180Vac±7V (UPS); 100Vac±7V (Appliances)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Loss Voltage\u003c\/td\u003e\n\u003ctd\u003e170Vac±7V (UPS) 90Vac±7V (Appliances)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Input Current\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e300Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charging Current\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Input Current\u003c\/td\u003e\n\u003ctd\u003e27A x 2(MAX 40A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Array Open Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e500Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz (Auto detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Short Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eLine mode: Circuit Breaker (70A) Battery mode: Electronic Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Array MPPT Voltage Range\u003c\/td\u003e\n\u003ctd\u003e90Vdc 450Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart-up Voltage\u003c\/td\u003e\n\u003ctd\u003e80V +\/- 5Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax parallel numbers\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Offset\u003c\/td\u003e\n\u003ctd\u003e≤100mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh DC Cut-off Voltage\u003c\/td\u003e\n\u003ctd\u003e63Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh DC Recovery Voltage\u003c\/td\u003e\n\u003ctd\u003e61Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow DC Cut-off Voltage\u003c\/td\u003e\n\u003ctd\u003e44Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e48Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Efficiency\u003c\/td\u003e\n\u003ctd\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Current\u003c\/td\u003e\n\u003ctd\u003e150A UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Start Voltage\u003c\/td\u003e\n\u003ctd\u003e46.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003eDC Offset ≦100mV Power Limitation 55Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;95% ( Rated R load Line Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloating Charging Voltage\u003c\/td\u003e\n\u003ctd\u003e54Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Waveform\u003c\/td\u003e\n\u003ctd\u003eSinusoidal (utility or generator) Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eCharge Time to\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e60Hz or 50Hz Peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Regulation\u003c\/td\u003e\n\u003ctd\u003e230Vac± 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercharge Protection\u003c\/td\u003e\n\u003ctd\u003e63Vdc Charging Algorithm 3-Step Charging Curve Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eSurge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power\u003c\/td\u003e\n\u003ctd\u003e11000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e11000W Max. PV Array Open Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e10ms typical (UPS);\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Regulation (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003e230VAC ± 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Power\u003c\/td\u003e\n\u003ctd\u003e22000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency (Peak)\u003c\/td\u003e\n\u003ctd\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloating Charge Voltage\u003c\/td\u003e\n\u003ctd\u003e54 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolar Charger Type\u003c\/td\u003e\n\u003ctd\u003eMPPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV Array Power\u003c\/td\u003e\n\u003ctd\u003e13000W (6500W x 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Range @ Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e90 – 450 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV Array Open Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV Input Current\u003c\/td\u003e\n\u003ctd\u003e40A\/27A (MAX 60A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Solar Charge Current\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC Charge Current\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Charge Current\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance Safety\u003c\/td\u003e\n\u003ctd\u003eIEC 62109, IEC 61683, EN\/IEC 61000-6-2, 61000-6-4, 61000-3-11, 61000-3-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension, D x W x H (mm)\u003c\/td\u003e\n\u003ctd\u003e158.4 x 503.6 x 530.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kgs)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eUSB\/RS232\/RS485\/WiFi\/Dry-contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-15°C~ 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e IEC 62109, IEC 61683, EN\/IEC 61000-6-2, 61000-6-4, 61000-3-11, 61000-3-12\u003c\/p\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the main performance specifications of the Axpert MAX II TWIN?\u003c\/summary\u003e\u003cp\u003eThe Axpert MAX II TWIN has a rated power of 11000VA\/11000W with a peak efficiency of 93%. It provides a pure sine wave output with an AC voltage regulation of 230VAC ± 5% in battery mode.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the Axpert MAX II TWIN compatible with different battery types and solar panels?\u003c\/summary\u003e\u003cp\u003eYes, the inverter is compatible with a 48 VDC battery system and supports MPPT solar chargers with a maximum PV array power of 11000W, making it suitable for various solar panel configurations.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the physical specifications of the Axpert MAX II TWIN?\u003c\/summary\u003e\u003cp\u003eThe physical dimensions and weight of the Axpert MAX II TWIN are not specified here, but it is designed to be robust and suitable for residential and commercial installations. Please refer to the product manual for detailed dimensions and weight.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the installation requirements for the Axpert MAX II TWIN?\u003c\/summary\u003e\u003cp\u003eInstallation should be performed by a qualified technician. Ensure that the inverter is installed in a well-ventilated area, away from direct sunlight and moisture, and that all electrical connections comply with local regulations.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat warranty does Voltronic Power offer for the Axpert MAX II TWIN?\u003c\/summary\u003e\u003cp\u003eVoltronic Power typically offers a standard warranty for its products, but specific warranty terms for the Axpert MAX II TWIN should be confirmed with the retailer or distributor.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat certifications does the Axpert MAX II TWIN have?\u003c\/summary\u003e\u003cp\u003eThe Axpert MAX II TWIN is certified under IEC 62109, IEC 61683, EN\/IEC 61000-6-2, 61000-6-4, 61000-3-11, and 61000-3-12, ensuring compliance with international safety and performance standards.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the operating conditions for the Axpert MAX II TWIN?\u003c\/summary\u003e\u003cp\u003eThe inverter is designed to operate efficiently within a specific temperature and humidity range. For optimal performance, ensure the environment is within the recommended conditions as specified in the product manual.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the key features and benefits of the Axpert MAX II TWIN?\u003c\/summary\u003e\u003cp\u003eKey features include a high surge power of 22000VA, fast transfer time of 10 ms for PCs, and 20 ms for home appliances, along with MPPT solar charging capabilities, making it ideal for both residential and commercial use.\u003c\/p\u003e\u003c\/details\u003e","brand":"Voltronic Power","offers":[{"title":"Default Title","offer_id":47936696221801,"sku":"VOLTRONIC-AXPERT-MAX-II-TWIN-11K","price":2900.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/axpert_max_ii_twin_8_12kw.jpg?v=1787308829","url":"https:\/\/www.solarinstaller.ae\/products\/axpert-max-ii-twin-8-12kw-11000va-11000w","provider":"Solar Installer","version":"1.0","type":"link"}