{"product_id":"arena","title":"Voltronic Power Arena 2U\/3U","description":"\u003cp\u003eThe Voltronic Power Arena 2U\/3U UPS is engineered to deliver exceptional power protection with its robust 3-phase voltage capabilities. Designed to handle a wide voltage range and frequency, it ensures stable and reliable power supply for critical applications. Ideal for data centers, industrial facilities, and telecommunications, the Arena 2U\/3U UPS provides seamless power continuity and protection against voltage fluctuations.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue double-conversion\u003c\/li\u003e\n\u003cli\u003eDSP technology guarantees high reliability\u003c\/li\u003e\n\u003cli\u003eOutput power factor 1.0\u003c\/li\u003e\n\u003cli\u003e50Hz\/60Hz frequency converter mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECO mode operation for energy\u003c\/strong\u003e — ECO mode operation for energy saving\u003c\/li\u003e\n\u003cli\u003eEmergency power off function (EPO)\u003c\/li\u003e\n\u003cli\u003eGenerator compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomized system (only available for\u003c\/strong\u003e — Customized system (only available for Arena 3U)\u003c\/li\u003e\n\u003cli\u003eParallel operation with common battery\u003c\/li\u003e\n\u003cli\u003eAdjustable battery design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e3 x 360VAC\/380VAC\/400VAC\/415VAC (3Ph+N+PE) \/ 208VAC\/220VAC\/230VAC\/240VAC (1Ph+N+PE) \/ 100\/200, 110\/220, 120\/208, 120\/240, 127\/220 VAC (2Ph+N+PE) \/ 3 x 173VAC\/190VAC\/200VAC\/208VAC\/220VAC (3Ph+N+PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load \/ 110-300 VAC @ 50% load, 176-276 VAC @ 100% load \/ 88-155 VAC (L-N), 152-269 VAC (L-L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e40 Hz ~ 70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 0.99 @ 100% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHDi\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 4% @ full linear load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e360VAC\/380VAC\/400VAC\/415VAC (3Ph+N) \/ 208*220\/230\/240VAC(L+N) \/ 100\/200,110\/220,120\/208,120\/240,127\/220VAC(2Ph+N) \/ 173VAC\/190VAC\/200VAC\/208VAC\/220VAC(3Ph+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Regulation (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003e± 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Synchronized Range)\u003c\/td\u003e\n\u003ctd\u003e46~54Hz or 56~64Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003e50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Crest Ratio\u003c\/td\u003e\n\u003ctd\u003e3:1 (max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Distortion\u003c\/td\u003e\n\u003ctd\u003e≤ 2% THD (Linear Load) ; ≤ 3% THD (Non-linear Load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003ePure Sinewave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Mode\u003c\/td\u003e\n\u003ctd\u003e94% \/ 93.5% \/ 91% \/ 92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECO Mode\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Mode At Full Load\u003c\/td\u003e\n\u003ctd\u003e93% \/ 92.5% \/ 92% \/ 91%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Mode Peak\u003c\/td\u003e\n\u003ctd\u003e93.5% \/ 93% \/ 92.5% \/ 91.5% \/ 92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e± 12V \/ 9 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Numbers\u003c\/td\u003e\n\u003ctd\u003e12 pcs x 2 \/ 6 pcs x 2 \/ 16~20 pcs (adjustable) x 2 \/ 8~10pcs (adjustable) x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Voltage\u003c\/td\u003e\n\u003ctd\u003e± 164V \/ ± 82V \/ ± 218V \/ ± 109V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharging Time\u003c\/td\u003e\n\u003ctd\u003e9 hours recover to 90% capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Current\u003c\/td\u003e\n\u003ctd\u003e± 4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCD\/LED Display\u003c\/td\u003e\n\u003ctd\u003eUPS status, Load level, Battery level, Input\/Output voltage, Discharge timer, and Fault conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart RS-232\/USB\u003c\/td\u003e\n\u003ctd\u003eSupports Windows® Family, Linux and MAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional SNMP\u003c\/td\u003e\n\u003ctd\u003ePower management from SNMP manager and web browser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension, D x W x H(mm)\u003c\/td\u003e\n\u003ctd\u003e678 x 418 x 88 [2U] \/ 678 x 418 x 129 [3U]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kgs)\u003c\/td\u003e\n\u003ctd\u003e17 \/ 14 \/ 20.5 \/ 17.6 \/ 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e17 \/ 14 \/ 20.5 \/ 17.6 \/ 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0-95 % RH @ 0- 40°C (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003eLess than 55dB @ 1 Meter \/ Less than 58dB @ 1 Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the main performance specifications of the Arena 2U\/3U UPS?\u003c\/summary\u003e\u003cp\u003eThe Arena 2U\/3U UPS offers high efficiency with an AC mode efficiency of 94% and an ECO mode efficiency of 97%. It supports a nominal voltage of 3 x 360VAC to 415VAC and maintains a power factor of \u0026gt;= 0.99 at full load.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the Arena 2U\/3U UPS compatible with different battery types or solar panels?\u003c\/summary\u003e\u003cp\u003eThe Arena 2U\/3U UPS is designed to work seamlessly with various battery types and can be integrated into solar panel systems, making it versatile for different power setups.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the physical specifications of the Arena 2U\/3U UPS?\u003c\/summary\u003e\u003cp\u003eThe Arena 2U\/3U UPS is designed to fit standard rack dimensions. For detailed dimensions and weight, please refer to the product manual or contact Voltronic Power.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the installation requirements for the Arena 2U\/3U UPS?\u003c\/summary\u003e\u003cp\u003eInstallation requires a stable environment with proper ventilation. It should be installed by a qualified technician to ensure compliance with safety standards and optimal performance.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is the warranty period for the Arena 2U\/3U UPS?\u003c\/summary\u003e\u003cp\u003eThe Arena 2U\/3U UPS comes with a standard warranty period, which typically covers parts and labor. For specific warranty details, please refer to the warranty documentation provided with the product.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat certifications and standards does the Arena 2U\/3U UPS comply with?\u003c\/summary\u003e\u003cp\u003eThe Arena 2U\/3U UPS complies with standard certifications, ensuring it meets international safety and performance standards. For detailed certification information, please consult the product documentation.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the operating conditions for the Arena 2U\/3U UPS?\u003c\/summary\u003e\u003cp\u003eThe UPS is designed to operate efficiently in a temperature range of 0°C to 40°C and a humidity range of 0% to 95% non-condensing.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the key features and benefits of the Arena 2U\/3U UPS?\u003c\/summary\u003e\u003cp\u003eKey features include zero transfer time, pure sinewave output in battery mode, and low harmonic distortion, making it ideal for sensitive equipment. Its high efficiency and robust design offer reliable power protection.\u003c\/p\u003e\u003c\/details\u003e","brand":"Voltronic Power","offers":[{"title":"Default Title","offer_id":47936688914537,"sku":"VOLTRONIC-ARENA-2U-3U","price":25000.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/arena.jpg?v=1787308785","url":"https:\/\/www.solarinstaller.ae\/products\/arena","provider":"Solar Installer","version":"1.0","type":"link"}