{"title":"String Inverters","description":"\u003cp\u003eProven, cost-effective conversion for standard rooftop arrays.\u003c\/p\u003e","products":[{"product_id":"deye-sun-g04p1-eu-am1","title":"Deye 1–4 kW Single-Phase Solar Inverter","description":"\u003cp\u003eEvery model here is a single-phase solar inverter built for a house, a shop or a small workshop on a 220\/230 V supply. The range runs from 1 kW to 4 kW across ten steps, and all ten sit in the same 6.35 kg case, so sizing up costs nothing in wall space. They begin generating at 80 V, which means the array is working on weak morning light instead of waiting for full sun.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eThe same body at every rating: 6.35 kg, 280 x 310 x 184 mm, so the bracket and the wall space never change when you size up.\u003c\/li\u003e\n\u003cli\u003eStarts generating from 80 V, so the panels earn from first light rather than mid-morning.\u003c\/li\u003e\n\u003cli\u003eOne MPPT tracker, taking up to 550 V and 20 A from the array.\u003c\/li\u003e\n\u003cli\u003eSealed to IP65 and cooled by air alone at 35 dB or less, so it can hang on an outside wall with no fan to hear or clean.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e1 kW single-phase solar inverter for a cabin, kiosk or small shop\u003c\/h3\u003e\u003cp\u003eThe smallest step in the range, rated 1 kW and taking up to 1,300 W of panels, which is roughly two or three modern modules. Output tops out at 5 A, so it feeds an ordinary lighting and socket circuit without any switchboard work. Maximum efficiency is 97.3%, and the panel string is designed around a nominal 360 V.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 1 kW · Max PV input power: 1,300 W · Max AC output current: 5 A · Max efficiency: 97.3%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-1K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e1.5 kW single-phase solar inverter for a small flat or holiday home\u003c\/h3\u003e\u003cp\u003eRated 1.5 kW with room for 2,000 W of panels, this step suits a small flat or a weekend house where the daytime load is a fridge, a few fans and lighting. Maximum AC current is 7.5 A and apparent power 1,650 VA. Efficiency peaks at 97.3%, the same as the smaller unit, and the string is built around a nominal 360 V.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 1.5 kW · Max PV input power: 2,000 W · Max AC output current: 7.5 A · Max apparent power: 1,650 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-1.5K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e2 kW single-phase solar inverter to cover a home's daytime base load\u003c\/h3\u003e\u003cp\u003eAt 2 kW rated output and 2,600 W of panel capacity, this is the point where a household starts covering its own daytime running costs rather than just trimming them. It gives 10 A on the AC side and 2,200 VA of apparent power. Peak efficiency is 97.3% and the string sits around a nominal 360 V, so one row of panels does the job.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 2 kW · Max PV input power: 2,600 W · Max AC output current: 10 A · Max apparent power: 2,200 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-2K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e2.2 kW single-phase solar inverter for a 2.9 kW rooftop array\u003c\/h3\u003e\u003cp\u003eRated 2.2 kW and accepting 2,900 W of panels, this step exists for arrays that overshoot the 2 kW unit by a module or two. Maximum AC current is 11 A and apparent power 2,420 VA. Efficiency stays at 97.3% like the rest of the lower half of the range, and the string runs at a nominal 360 V.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 2.2 kW · Max PV input power: 2,900 W · Max AC output current: 11 A · Max apparent power: 2,420 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-2.2K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e2.5 kW single-phase solar inverter for a three-bedroom house roof\u003c\/h3\u003e\u003cp\u003eThis rating handles 3,300 W of panels against 2.5 kW of rated output, a comfortable ratio for a roof that loses sun late in the afternoon. Maximum AC current is 12.5 A and apparent power 2,750 VA. It keeps the 97.3% peak efficiency and the 360 V nominal string used by the smaller units in the family.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 2.5 kW · Max PV input power: 3,300 W · Max AC output current: 12.5 A · Max apparent power: 2,750 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-2.5K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e2.7 kW single-phase solar inverter for a 3.5 kW panel array\u003c\/h3\u003e\u003cp\u003eThe last of the 97.3% efficiency group, rated 2.7 kW and taking 3,500 W of panels. AC output reaches 13.5 A with 2,970 VA of apparent power. Take this over the 2.5 kW step when the array plan lands just past 3.3 kW of modules and you would rather not clip the peak on bright, cool days.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 2.7 kW · Max PV input power: 3,500 W · Max AC output current: 13.5 A · Max apparent power: 2,970 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-2.7K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e3 kW single-phase solar inverter, the common size for a family home\u003c\/h3\u003e\u003cp\u003eThe most-asked-for rating in the range, good for 3,900 W of panels against 3 kW of output. This is also where peak efficiency steps up to 97.5% from the 97.3% of the smaller units, so a little more of what the roof makes reaches the meter. Maximum AC current is 15 A and apparent power 3,300 VA, with the string still around a nominal 360 V.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 3 kW · Max PV input power: 3,900 W · Max AC output current: 15 A · Max efficiency: 97.5%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e3.3 kW single-phase solar inverter with a 420 V nominal panel string\u003c\/h3\u003e\u003cp\u003eRated 3.3 kW with 4,300 W of panel capacity and 97.5% peak efficiency. This is the first step whose string is designed around a nominal 420 V rather than 360 V, so it wants a longer run of panels in series than the smaller units and your layout has to allow for that. Maximum AC current is 16.5 A, apparent power 3,630 VA.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 3.3 kW · Max PV input power: 4,300 W · Max AC output current: 16.5 A · Rated PV input voltage: 420 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3.3K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e3.6 kW single-phase solar inverter for a villa roof, 4.7 kW of panels\u003c\/h3\u003e\u003cp\u003eRated 3.6 kW and accepting 4,700 W of panels, this suits a full villa roof where the array is deliberately oversized to hold output up through the middle of the day. Maximum AC current is 18 A and apparent power 3,960 VA. Peak efficiency is 97.5% and the panel string is built around a nominal 420 V.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 3.6 kW · Max PV input power: 4,700 W · Max AC output current: 18 A · Max apparent power: 3,960 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3.6K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e4 kW single-phase solar inverter, the top step before three-phase\u003c\/h3\u003e\u003cp\u003eThe largest single-phase model, rated 4 kW with 5,200 W of panel capacity and 20 A of AC output, which is about the practical ceiling before a utility asks for a three-phase connection instead. Apparent power is 4,400 VA and peak efficiency 97.5%. It shares the 6.35 kg case with the 1 kW unit, so the install is no heavier than the smallest one here.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 4 kW · Max PV input power: 5,200 W · Max AC output current: 20 A · Max apparent power: 4,400 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-4K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 10 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e70-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/230 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e80-550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e1\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003eL\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99, VDE-AR-N 4105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Operating Current (A)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e6.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to +65℃,\u0026gt;45℃ derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"1 kW","offer_id":47869736943721,"sku":"SUN-1K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"1.5 kW","offer_id":47869736976489,"sku":"SUN-1.5K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"2 kW","offer_id":47869737009257,"sku":"SUN-2K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"2.2 kW","offer_id":47869737042025,"sku":"SUN-2.2K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"2.5 kW","offer_id":47869737074793,"sku":"SUN-2.5K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"2.7 kW","offer_id":47869737107561,"sku":"SUN-2.7K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"3 kW","offer_id":47869737140329,"sku":"SUN-3K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"3.3 kW","offer_id":47869737173097,"sku":"SUN-3.3K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"3.6 kW","offer_id":47869737205865,"sku":"SUN-3.6K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"4 kW","offer_id":47869737238633,"sku":"SUN-4K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-1-4K-G04P1.png?v=1785851346"},{"product_id":"deye-sun-g02p1-eu-am2","title":"Deye 7–10.5 kW Single-Phase Solar Inverter","description":"\u003cp\u003eThis is Deye's single-phase solar inverter for houses and small businesses that have outgrown a 5 kW unit. Six ratings sit under one listing, from 7 kW up to 10.5 kW, and every one of them converts at up to 97.7% with two independent panel inputs. The smaller three share a 12.1 kg body; the 9 kW and above move to a taller 14.8 kg case with a front screen and Wi-Fi on board.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e97.7% peak conversion, 97.2% on the European weighted average, on all six ratings\u003c\/li\u003e\n\u003cli\u003eTwo panel inputs tracking 70 V to 500 V, waking at 80 V so it starts early in the morning\u003c\/li\u003e\n\u003cli\u003eSealed well enough to sit on an outside wall (IP65), fanless, and under 35 dB\u003c\/li\u003e\n\u003cli\u003eRated from -25 to +60 C and up to 3000 m altitude, with 5 years of warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e7 kW single-phase solar inverter for a rooftop array up to 10.5 kW\u003c\/h3\u003e\u003cp\u003eThe entry point in this range, and the size most 6 kW to 8 kW rooftops land on. It takes up to 10.5 kW of panels across its two inputs and pushes out 35 A at full tilt, which is 7.7 kVA of apparent power. At 12.1 kg it is light enough for one person to lift onto a bracket. Monitoring runs over RS485 or RS232, with Wi-Fi, Bluetooth, 4G or LAN as an optional stick.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 10.5 kW · Max AC output current: 35 A · Apparent power: 7.7 kVA · Weight: 12.1 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7K-G02P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7.5 kW single-phase string inverter, 11.3 kW of panels, 12.1 kg\u003c\/h3\u003e\u003cp\u003eA half step above the 7 kW, worth taking when the array lands near 11 kW. Panel input tops out at 11.3 kW and the AC side gives 37.5 A, or 8.25 kVA. Cabinet, weight and cooling are identical to the 7 kW and 8 kW: the same 12.1 kg fanless case and the same pair of 18 A and 26 A panel inputs. Pick it only if your string layout genuinely sits between the two.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 11.3 kW · Max AC output current: 37.5 A · Apparent power: 8.25 kVA · Weight: 12.1 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7.5K-G02P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW single-phase solar inverter, 12 kW panel input, 40 A output\u003c\/h3\u003e\u003cp\u003eThe top of the lighter chassis. It accepts 12 kW of panels and its AC output reaches 40 A at 8.8 kVA, which suits a well-loaded roof on one phase. The body is the same 12.1 kg unit as the 7 kW and 7.5 kW, so mounting and clearance planning do not change. If the design calls for more than 12 kW of modules, move up to the 9 kW and its taller case.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 12 kW · Max AC output current: 40 A · Apparent power: 8.8 kVA · Weight: 12.1 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-G02P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e9 kW single-phase inverter with an LCD screen and 13.5 kW PV input\u003c\/h3\u003e\u003cp\u003eFirst model in the taller 14.8 kg case, and the first with an LCD1602 screen on the front, so an installer can read a fault without a phone. Both panel inputs are rated 26 A here rather than 18 A and 26 A, which suits two strings of equal length. It handles 13.5 kW of panels and 45 A of output, and Wi-Fi and LAN are part of the standard communication set instead of an add-on.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 13.5 kW · Max AC output current: 45 A · Apparent power: 9.9 kVA · Weight: 14.8 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-9K-G02P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e10 kW single-phase solar inverter for a 15 kW array, Wi-Fi built in\u003c\/h3\u003e\u003cp\u003eThe workhorse of the larger three. Panel input stretches to 15 kW and output reaches 50 A, or 11 kVA of apparent power, which covers a large villa or a small workshop running on one phase. Body, screen and twin 26 A inputs match the 9 kW and 10.5 kW, at 14.8 kg. Choose it over the 9 kW when the roof has space for more than 13.5 kW of modules.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 15 kW · Max AC output current: 50 A · Apparent power: 11 kVA · Weight: 14.8 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10K-G02P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e10.5 kW single-phase solar inverter, the largest in this range\u003c\/h3\u003e\u003cp\u003eThe largest single-phase unit in this family. It takes 15.8 kW of panels and delivers 52.5 A, or 11.55 kVA, which is a lot of current to carry on one phase and worth checking against your incoming supply. Everything mechanical matches the 9 kW and 10 kW: 14.8 kg, natural cooling, no fan to service. Past this point the sensible move is a three-phase inverter rather than a bigger single-phase one.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 15.8 kW · Max AC output current: 52.5 A · Apparent power: 11.55 kVA · Weight: 14.8 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10.5K-G02P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 6 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFCI Protection\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e70-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e80-550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD1602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to +60℃, \u0026gt;45℃ Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"7 kW","offer_id":47869737271401,"sku":"SUN-7K-G02P1-EU-AM2","price":2800.0,"currency_code":"AED","in_stock":true},{"title":"7.5 kW","offer_id":47869737304169,"sku":"SUN-7.5K-G02P1-EU-AM2","price":2800.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869737336937,"sku":"SUN-8K-G02P1-EU-AM2","price":2800.0,"currency_code":"AED","in_stock":true},{"title":"9 kW","offer_id":47869737369705,"sku":"SUN-9K-G02P1-EU-AM2","price":3675.0,"currency_code":"AED","in_stock":true},{"title":"10 kW","offer_id":47869737402473,"sku":"SUN-10K-G02P1-EU-AM2","price":3675.0,"currency_code":"AED","in_stock":true},{"title":"10.5 kW","offer_id":47869737435241,"sku":"SUN-10.5K-G02P1-EU-AM2","price":3675.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-9-10.5K-G02P1.png?v=1785851349"},{"product_id":"deye-sun-g03-p3","title":"Deye 70–110 kW Three-Phase Solar Inverter","description":"\u003cp\u003eThis is Deye's heavy end of the three-phase solar inverter range, the box you put on a factory roof, a cold store or a small solar farm feeding a 380\/400 V supply. Six ratings share one cabinet, so the choice comes down to how many panels you are connecting and how much current the site can take. Every unit runs on the grid alone, with no battery involved.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOne cabinet across all six ratings: 824 x 516 x 312.7 mm and 81 kg, so the mounting frame and the lifting plan never change\u003c\/li\u003e\n\u003cli\u003eSealed to IP65 and rated from -25C to 60C, which means it can hang on an outside wall in Gulf or Levant heat\u003c\/li\u003e\n\u003cli\u003eApproved for sites up to 4,000 m above sea level, covering highland projects in Africa and the Levant\u003c\/li\u003e\n\u003cli\u003eCurrent distortion stays under 3% THD, with anti-islanding, residual current detection and thermal protection built in\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e70 kW three-phase inverter for a factory roof of about 105 kW\u003c\/h3\u003e\u003cp\u003eThe entry point of the range. It accepts up to 105 kW of panels across four independent trackers, so a roof split over two or three orientations still gets tracked properly. Output tops out at 116.7 A per phase, with 106.1 A at the rated point, and the strings can run as high as 1,100 V. Its full-load tracking window is 570 to 850 V, the roomiest of the four-tracker units.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 70 kW · Max PV input: 105 kW · MPPT trackers: 4 · Max AC output current: 116.7 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-70K-G03\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e75 kW string inverter, 112.5 kW of panels on four trackers\u003c\/h3\u003e\u003cp\u003eA half step up from the 70 kW for sites where the roof takes a few more strings. It handles 112.5 kW of panels and 82.5 kVA of apparent power, giving 125 A maximum per phase against 113.6 A rated. Deye lists its rated PV input voltage at 720 V and its full-load tracking window at 610 to 850 V, so it prefers longer strings than the 70 kW does.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 75 kW · Max PV input: 112.5 kW · Apparent power: 82.5 kVA · Max AC output current: 125 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-75K-G03\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e80 kW three-phase inverter for 120 kW of panels, 133.3 A out\u003c\/h3\u003e\u003cp\u003eThe largest of the four-tracker units. It takes 120 kW of panels, rated at 88 kVA, and pushes up to 133.3 A per phase with 121.2 A at the rated point. Its full-load tracking window starts at 650 V, the highest in the range, so strings need to be long enough to sit above that before it delivers full output. Cabling and breakers should be sized for the 133.3 A figure.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 80 kW · Max PV input: 120 kW · Apparent power: 88 kVA · Full-load MPPT window: 650-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-80K-G03\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e90 kW solar inverter with six MPPT trackers and 135 kW PV input\u003c\/h3\u003e\u003cp\u003eThis is where the range switches to six trackers, so a complicated roof with six different string groups can go on one machine. It accepts 135 kW of panels and 99 kVA, delivering up to 150 A per phase. The six-tracker units also drop the maximum string voltage to 1,000 V and narrow the tracking window to 200 to 850 V, which changes how strings are laid out compared with the 70 to 80 kW units.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 90 kW · Max PV input: 135 kW · MPPT trackers: 6 · Max PV input voltage: 1,000 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-90K-G03\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e100 kW three-phase inverter, 150 kW of panels on six trackers\u003c\/h3\u003e\u003cp\u003eA 100 kW machine sharing the six-tracker platform with the 90 and 110 kW. It carries the highest panel ceiling in the range at 150 kW, tracks between 200 and 850 V and accepts strings up to 1,000 V. Worth knowing before you choose: Deye's table gives the 100 kW and the 110 kW the same 150 kW input ceiling and the same output current column, so the honest difference between them is the 100 kW rated output itself.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 100 kW · Max PV input: 150 kW · MPPT trackers: 6 · MPPT window: 200-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-100K-G03\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e110 kW inverter, the largest rating in Deye's G03 string range\u003c\/h3\u003e\u003cp\u003eThe top of the range at 110 kW of rated AC output, for the largest roofs and ground mounts on a 380\/400 V connection. It shares the six-tracker cabinet with the 100 kW model, along with the 150 kW panel ceiling, the 200 to 850 V tracking window and the 1,000 V string limit; the datasheet lists no separate current figures for it. Pick this one when the connection agreement allows the extra 10 kW of export.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 110 kW · Max PV input: 150 kW · MPPT trackers: 6 · Max PV input voltage: 1,000 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-110K-G03\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 6 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Full Load Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e550-850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e6\/4+4+4+4+4+4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eUNEIEC61727,217002,IECOVE-Richtlinie62116,CEI0-21,R25,CEIG99,0-16,VDE-AR-NEN50549,4105,NRSVDE-AR-N097,RD140,4110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC),OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eDC Injection Current: \u0026lt;0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"70 kW","offer_id":47869737468009,"sku":"DEYE-SUN-70K-G03","price":27500.0,"currency_code":"AED","in_stock":true},{"title":"75 kW","offer_id":47869737500777,"sku":"DEYE-SUN-75K-G03","price":27500.0,"currency_code":"AED","in_stock":true},{"title":"80 kW","offer_id":47869737533545,"sku":"DEYE-SUN-80K-G03","price":27500.0,"currency_code":"AED","in_stock":true},{"title":"90 kW","offer_id":47869737566313,"sku":"DEYE-SUN-90K-G03","price":27500.0,"currency_code":"AED","in_stock":true},{"title":"100 kW","offer_id":47869737599081,"sku":"DEYE-SUN-100K-G03","price":27500.0,"currency_code":"AED","in_stock":true},{"title":"110 kW","offer_id":47869737631849,"sku":"DEYE-SUN-110K-G03","price":27500.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-70-110K-G03.png?v=1785851350"},{"product_id":"deye-sun-g05-lv-p3","title":"Deye 10–15 kW Three-Phase Low-Voltage Solar Inverter","description":"\u003cp\u003eThis is Deye's three-phase solar inverter for a building already wired with a 220V or 230V three-phase supply, sold here in 10, 12 and 15 kW ratings. All three send everything the panels make straight into the building and the grid, with no battery involved, at a weighted European efficiency of 98%. The cabinet is identical across the range, so sizing up later changes nothing about the bracket or the cable run.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConnects to a 127\/220V or 133\/230V three-phase supply on 3L\/N\/PE, at 50 or 60 Hz\u003c\/li\u003e\n\u003cli\u003eTwo panel inputs, each accepting up to 26 A, with an 800 V ceiling and a 250 V start-up\u003c\/li\u003e\n\u003cli\u003e98.6% peak efficiency, 98% European weighted, and current distortion held under 3%\u003c\/li\u003e\n\u003cli\u003eSealed to IP65 and cleared to 4,000 m altitude, so an outside wall in a hot yard is fine (up to 60C)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e10 kW three-phase solar inverter for a villa or small shop rooftop\u003c\/h3\u003e\u003cp\u003eThe 10 kW takes up to 13 kW of panels, which leaves room for the usual oversizing, and pushes 26.3 A per phase into the building. Its full load window opens at 250 V, the lowest of the three, so short strings and dull winter mornings still hold rated output. Its input and output apparent power limit is 11 kVA. Choose it when the three-phase daytime load sits near 10 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 13 kW · Rated AC output current: 26.3 A · Full-load MPPT window: 250-700 V · Max input\/output apparent power: 11 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10K-G05-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e12 kW three-phase string inverter for a workshop or small factory\u003c\/h3\u003e\u003cp\u003eThe 12 kW sits in the middle of the range: 15.6 kW of panels, 31.5 A per phase and 13.2 kVA of apparent power. Its full load window starts at 300 V, so strings need to be a little longer here than on the 10 kW before the inverter will hold full output. It is the usual pick for a workshop or a pump shed whose daytime draw runs between 10 and 13 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 15.6 kW · Rated AC output current: 31.5 A · Full-load MPPT window: 300-700 V · Max input\/output apparent power: 13.2 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-12K-G05-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e15 kW three-phase solar inverter for a small commercial rooftop\u003c\/h3\u003e\u003cp\u003eThe 15 kW is the top of this range and takes 19.5 kW of panels, 6.5 kW more than the 10 kW unit, at 39.4 A per phase. Plan longer strings for it: full output needs at least 375 V from the array. Active and apparent power are both 15, so there is no reserve above the rating, worth knowing if motors dominate the load. Cabinet and weight match the smaller two.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 19.5 kW · Rated AC output current: 39.4 A · Full-load MPPT window: 375-700 V · Max input\/output apparent power: 15 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-15K-G05-LV\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 3 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFCI Protection\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e2\/2+2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232 \/WiFi\/LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNBR 16149, NBR 16150, EN 50549, RD 140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e362 x 527 x 220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"10 kW","offer_id":47869737664617,"sku":"DEYE-SUN-10K-G05-LV","price":5250.0,"currency_code":"AED","in_stock":true},{"title":"12 kW","offer_id":47869737697385,"sku":"DEYE-SUN-12K-G05-LV","price":5250.0,"currency_code":"AED","in_stock":true},{"title":"15 kW","offer_id":47869737730153,"sku":"DEYE-SUN-15K-G05-LV","price":5250.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-10-15K-G05-LV.png?v=1785851352"},{"product_id":"deye-sun-g06p3-eu-am2-p1","title":"Deye 3–15 kW Three-Phase Solar Inverter (SUN-G06P3-EU-AM2-P1)","description":"\u003cp\u003eThe SUN-G06P3-EU-AM2-P1 is Deye's three-phase solar inverter for homes and small businesses that already sit on a 380 V or 400 V supply. It is sold in ten ratings, 3 kW through 15 kW, and every one of them uses the same 11 kg wall box with two MPPT trackers and a 1,100 V panel input. Pick the rating that matches the array going on the roof; the rest of the machine does not change.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo MPPT trackers with a 120 V to 1,000 V tracking window, and panel strings allowed up to 1,100 V\u003c\/li\u003e\n\u003cli\u003eSealed for an outside wall (IP65) and rated from -25 C to 60 C, up to 4,000 m altitude\u003c\/li\u003e\n\u003cli\u003eUnder 45 dB of running noise and 11 kg on the bracket, so one person can hang it\u003c\/li\u003e\n\u003cli\u003eFeeds a 220\/380 V or 230\/400 V three-phase supply at 50 or 60 Hz, with grid, earth-fault and anti-islanding monitoring on board\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3 kW three-phase solar inverter for a small rooftop of about 4.5 kW\u003c\/h3\u003e\u003cp\u003eThe smallest of the ten, sized for a house or a shop with roughly 4.5 kW of panels, which is the most DC power it will take. It puts out 3,000 W of real power, 3.3 kVA at the ceiling, and 4.6 A per phase in normal running. Peak conversion is 98.1%, or 97.5% on the European weighting. There is no fan in this one, so nothing on it needs cleaning or replacing.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 4.5 kW · Max apparent power: 3.3 kVA · Rated output current: 4.6 A per phase · Max efficiency: 98.1%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e4 kW three-phase solar inverter that takes up to 6 kW of solar panels\u003c\/h3\u003e\u003cp\u003eOne step up from the 3 kW and physically the same box. It accepts 6 kW of panels, half again more DC than its AC rating, which is what you want when the roof faces east and west rather than south. Normal running current is 6.1 A per phase with 6.7 A available, and apparent power tops out at 4.4 kVA. Efficiency is unchanged at 98.1% peak, 97.5% European.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 6 kW · Max apparent power: 4.4 kVA · Rated output current: 6.1 A per phase · Max AC output current: 6.7 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-4K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5 kW three-phase solar inverter, 7.5 kW of panels for a family home\u003c\/h3\u003e\u003cp\u003eThe usual choice for a family house on a three-phase meter. It takes 7.5 kW of panels against a 5,000 W output, so the array can be oversized without losing much at midday, and it holds 7.6 A per phase in normal running with 8.4 A in reserve. Efficiency moves up a notch here, to 98.2% at peak and 97.6% European. Cooling is still passive, with no fan to service.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 7.5 kW · Max apparent power: 5.5 kVA · Rated output current: 7.6 A per phase · Max efficiency: 98.2%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW three-phase solar inverter for a 9 kW roof, 10 A per phase\u003c\/h3\u003e\u003cp\u003eSame case and the same 98.2% peak efficiency as the 5 kW, with more headroom on both sides: 9 kW of panels on the DC side and 6.6 kVA on the AC side. Normal running current is 9.1 A per phase and the ceiling is 10 A, which is the figure that decides your cable and breaker. European efficiency is 97.6%. It is still cooled by air alone.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 9 kW · Max apparent power: 6.6 kVA · Rated output current: 9.1 A per phase · Max AC output current: 10 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7 kW three-phase solar inverter, 10.5 kW of panels for a small shop\u003c\/h3\u003e\u003cp\u003eIt is rated at 7,000 W with 7.7 kVA of apparent power and room for 10.5 kW of panels, which suits a shop or a workshop that runs through the day. Two numbers are missing here on purpose. The datasheet prints output current for this model in a cell shared with its neighbours, and our records disagree on whether peak efficiency is 98.2% or 98.3%. We would rather quote neither than quote the wrong one.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 7,000 W · Max PV input: 10.5 kW · Max apparent power: 7.7 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW three-phase solar inverter, 12 kW of panels at 98.3% efficiency\u003c\/h3\u003e\u003cp\u003eEfficiency is 98.3% at peak and 97.8% on the European weighting, matching the 7 kW and topping the smaller ratings. It swallows 12 kW of panels, a full half again over its 8,000 W output, and delivers 8.8 kVA. The case, the weight and the two trackers match the 3 kW exactly, so wall space and mounting do not change if you upsize during design.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 12 kW · Max apparent power: 8.8 kVA · Max efficiency: 98.3% · European efficiency: 97.8%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e9 kW three-phase solar inverter for 13.5 kW of panels, 15 A ceiling\u003c\/h3\u003e\u003cp\u003eNine thousand watts out, 13.5 kW of panels in, 9.9 kVA of apparent power and a 15 A ceiling per phase. It sits between the 8 kW and the 10 kW on the same 98.3% peak and 97.8% European efficiency, and it is the largest rating in this range that still runs without a fan. Choose it when the array lands slightly over what the 8 kW will accept.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 13.5 kW · Max apparent power: 9.9 kVA · Max AC output current: 15 A · Cooling: Passive, no fan\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-9K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e10 kW three-phase solar inverter for a 15 kW commercial rooftop\u003c\/h3\u003e\u003cp\u003eTen kilowatts is the common size for a villa with heavy air conditioning or a small commercial roof. It accepts 15 kW of panels, gives 11 kVA of apparent power and 16.7 A per phase, and it holds full output across a 350 V to 650 V string window, so string design matters more here than on the smaller units. Peak efficiency stays at 98.3%.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 15 kW · Max apparent power: 11 kVA · Max AC output current: 16.7 A · Full-load MPPT window: 350-650 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e12 kW three-phase solar inverter, 18 kW of panels for a workshop\u003c\/h3\u003e\u003cp\u003eTwelve thousand watts of output, 13.2 kVA apparent and 20 A per phase, fed by as much as 18 kW of panels. Like the 10 kW it holds full output across a 350 V to 650 V string window, and it carries the same 98.3% peak and 97.8% European efficiency. This is usually the point where an installer splits the array into two separate string groups, one per tracker.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 12,000 W · Max PV input: 18 kW · Max apparent power: 13.2 kVA · Max AC output current: 20 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-12K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e15 kW three-phase solar inverter, 22.5 kW of panels at 98.5% peak\u003c\/h3\u003e\u003cp\u003eThe top of the range, and one of three ratings here with intelligent air cooling rather than passive cooling, which is how it holds 15,000 W in Gulf heat. It also carries the best conversion figures in the family, 98.5% at peak and 98% European, and it takes 22.5 kW of panels against 16.5 kVA on the AC side. The 25 A per phase ceiling decides your cable size.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 22.5 kW · Max apparent power: 16.5 kVA · Max AC output current: 25 A · Max efficiency: 98.5%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-15K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 10 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e120-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e283 x 463 x 178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"3 kW","offer_id":47869737762921,"sku":"SUN-3K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"4 kW","offer_id":47869737795689,"sku":"SUN-4K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"5 kW","offer_id":47869737828457,"sku":"SUN-5K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869737861225,"sku":"SUN-6K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"7 kW","offer_id":47869737893993,"sku":"SUN-7K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869737926761,"sku":"SUN-8K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"9 kW","offer_id":47869737959529,"sku":"SUN-9K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"10 kW","offer_id":47869737992297,"sku":"SUN-10K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"12 kW","offer_id":47869738025065,"sku":"SUN-12K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"15 kW","offer_id":47869738057833,"sku":"SUN-15K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-3-15K-G06P3-P1.png?v=1785851355"},{"product_id":"deye-sun-g06p3-eu-bm2","title":"Deye 3–15 kW Three-Phase Solar Inverter (SUN-G06P3-EU-BM2)","description":"\u003cp\u003eThe G06P3 is Deye's three-phase solar inverter for a building that already has a 400 V supply: a villa, a shop, a small workshop. Ten ratings run from 3 kW to 15 kW inside the same slim wall box with two MPPT trackers, so the same installation method covers a starter array or a full commercial roof. Pick the rating that matches the panel count you can actually fit.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo MPPT trackers with a 120 V to 1000 V window, so panels can face two different directions\u003c\/li\u003e\n\u003cli\u003eIP65 case with no fan, rated under 45 dB, quiet enough for the wall outside a bedroom\u003c\/li\u003e\n\u003cli\u003eWorks from -25 C to 60 C and up to 4,000 m, with Type II surge protection on the DC and AC sides\u003c\/li\u003e\n\u003cli\u003eAccepts 1100 V of panel voltage and reports over WiFi, 4G, LAN or Bluetooth (optional dongle)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3 kW three-phase solar inverter for a starter 4.5 kW rooftop array\u003c\/h3\u003e\u003cp\u003eThe entry point of the range, matched to roughly 4,500 W of panels, which is where most small three-phase homes begin. Output is 3,000 W, or 3,300 VA at peak, and the inverter draws only 4.6 A per phase in normal running, so it rarely forces a change to the incoming board. Conversion tops out at 98.1%, and at 11.5 kg one person can hang it on the bracket.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 4,500 W · Max AC output current: 5 A · Max apparent power: 3,300 VA · Peak efficiency: 98.1%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e4 kW three-phase solar inverter for a 6 kW array on a small villa\u003c\/h3\u003e\u003cp\u003eOne step up from the 3 kW, and the difference sits entirely on the panel side: 6,000 W of modules instead of 4,500 W. Rated current is 6.1 A per phase with 6.7 A available at the ceiling, and apparent power reaches 4,400 VA. Peak efficiency stays at 98.1%. Choose this one when the roof has room for a few more panels than the 3 kW will take.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 6,000 W · Max AC output current: 6.7 A · Max apparent power: 4,400 VA · Peak efficiency: 98.1%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-4K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5 kW three-phase inverter, 7.5 kW of panels for a family home roof\u003c\/h3\u003e\u003cp\u003eThe common size for a four-bedroom house on a three-phase supply. It carries 7,500 W of panels, delivers 5,000 W continuously and 5,500 VA at peak, and moves 7.6 A per phase. Efficiency steps up to 98.2% peak with 97.6% on the European weighted scale, so slightly more of a cloudy morning reaches the meter than on the 3 kW and 4 kW models.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 7,500 W · Max AC output current: 8.4 A · Max apparent power: 5,500 VA · European efficiency: 97.6%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW three-phase solar inverter for 9 kW of panels on a larger house\u003c\/h3\u003e\u003cp\u003eSame 98.2% peak efficiency as the 5 kW, but with 9,000 W of panel capacity and 6,600 VA of apparent power behind it. Rated current is 9.1 A per phase, which still lands inside a normal three-phase domestic circuit. This is the size to pick when the array has grown past 8 kW but the loads are still household ones: air conditioning, a pool pump, an oven.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 9,000 W · Max AC output current: 10 A · Max apparent power: 6,600 VA · Peak efficiency: 98.2%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7 kW three-phase solar inverter for a 10.5 kW small business roof\u003c\/h3\u003e\u003cp\u003eAbove 6 kW the range changes gear. The 7 kW holds full output across a 480 V to 850 V string window and lifts peak efficiency to 98.3%, with 97.8% on the European scale. It takes 10,500 W of panels and can push 12.8 A per phase, or 7,700 VA. It suits a workshop or a retail unit where the daytime load is steady rather than peaky.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 10,500 W · Max AC output current: 12.8 A · Full-load MPPT window: 480 to 850 V · Peak efficiency: 98.3%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW three-phase solar inverter for a 12 kW array on a shop or office\u003c\/h3\u003e\u003cp\u003eIt shares the 12.8 A per phase output ceiling with the 7 kW, so the AC cabling is usually identical, but it accepts 12,000 W of panels rather than 10,500 W and delivers 8,800 VA. Peak efficiency is 98.3%. Worth the step up when the roof is already full and the extra panels would otherwise be clipped in the middle of a summer day.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 12,000 W · Max AC output current: 12.8 A · Max apparent power: 8,800 VA · European efficiency: 97.8%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e9 kW three-phase solar inverter for a 13.5 kW commercial rooftop\u003c\/h3\u003e\u003cp\u003eThe 9 kW takes 13,500 W of panels and raises the output ceiling to 15 A per phase and 9,900 VA, a real step past the 7 kW and 8 kW which both stop at 12.8 A. Efficiency stays at the 98.3% peak and 97.8% European figure of the mid range. It still weighs 11.5 kg, the same as every model below it, so the mounting job does not change.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 13,500 W · Max AC output current: 15 A · Max apparent power: 9,900 VA · Weight: 11.5 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-9K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e10 kW three-phase solar inverter for a 15 kW array, 12 kg cabinet\u003c\/h3\u003e\u003cp\u003eThis is where the hardware changes: the cabinet gains half a kilo, to 12 kg. The machine carries 15,000 W of panels, 11,000 VA of apparent power and 16.7 A per phase, while peak efficiency holds at 98.3%. Pick it when the array is planned at or just under 15 kW and the main breaker has room for the extra current.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 15,000 W · Max AC output current: 16.7 A · Max apparent power: 11,000 VA · Weight: 12 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e12 kW three-phase solar inverter for an 18 kW commercial panel array\u003c\/h3\u003e\u003cp\u003eThe 12 kW accepts 18,000 W of panels and delivers 13,200 VA, with 20 A per phase at the ceiling. Peak efficiency is 98.3%. It uses the same 12 kg cabinet as the 10 kW, so a site that outgrows 10 kW can normally take the larger unit on the same bracket and the same cable route. A usual choice on warehouse and clinic roofs.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 18,000 W · Max AC output current: 20 A · Max apparent power: 13,200 VA · Weight: 12 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-12K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e15 kW three-phase solar inverter, the largest G06P3 at 98.5% peak\u003c\/h3\u003e\u003cp\u003eThe top of the range and the most efficient of the ten: 98.5% peak and 98% on the European scale, against 98.3% for the models below. It takes 22,500 W of panels, 16,500 VA of apparent power and 25 A per phase. The cabinet is 188 mm deep, 10 mm more than the 3 kW, and weighs 12 kg. It is sized for a commercial roof running on one inverter rather than two.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 22,500 W · Max AC output current: 25 A · Peak efficiency: 98.5% · Cabinet depth: 188 mm\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-15K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 10 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IECOVE-Richtlinie62116,CEI0-21,R25,ENG98,50549,G99,NRSVDE-AR-N097,RD4105140,UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e120-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e19.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"3 kW","offer_id":47869738090601,"sku":"SUN-3K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"4 kW","offer_id":47869738123369,"sku":"SUN-4K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"5 kW","offer_id":47869738156137,"sku":"SUN-5K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869738188905,"sku":"SUN-6K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"7 kW","offer_id":47869738221673,"sku":"SUN-7K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869738254441,"sku":"SUN-8K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"9 kW","offer_id":47869738287209,"sku":"SUN-9K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"10 kW","offer_id":47869738319977,"sku":"SUN-10K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"12 kW","offer_id":47869738352745,"sku":"SUN-12K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"15 kW","offer_id":47869738385513,"sku":"SUN-15K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-3-15K-G06P3.png?v=1785851358"},{"product_id":"deye-sun-g01p3-eu-am8","title":"Deye 120–136 kW Three-Phase Solar Inverter","description":"\u003cp\u003eThis is the largest three-phase solar inverter Deye builds for rooftops and ground mounts that need real capacity: five ratings from 120 kW up to 136 kW, all on the same 103 kg chassis. Eight separate tracker inputs let you run strings at different angles or on different roof faces without one shaded string pulling the rest down. Every unit is sealed to IP65 and keeps working to 60°C ambient, with output derating above 45°C.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEight MPPT tracker inputs, each taking up to 40 A, so strings on different roof faces are handled separately.\u003c\/li\u003e\n\u003cli\u003e98.8% peak efficiency and 98.2% European efficiency across the whole range.\u003c\/li\u003e\n\u003cli\u003eIP65 sealed with intelligent air cooling, rated from -25°C to 60°C and up to 4,000 m altitude.\u003c\/li\u003e\n\u003cli\u003eThe same 1006 x 516 x 325.5 mm body at 103 kg, so mounting hardware is identical whichever rating you pick.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e120 kW three-phase inverter for large commercial rooftops and sheds\u003c\/h3\u003e\u003cp\u003eThe 120 kW is the only unit here rated at 132 kVA, and its 200 A maximum output current is the lowest in the range, which usually means a smaller AC cable and a cheaper breaker. Rated output current sits at 181.9 A. It accepts up to 180 kW of panels, so a 1.5 ratio of array to inverter still fits. Pick it when the grid connection caps you near 120 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 120 kW · Max apparent power: 132 kVA · Max AC output current: 200 A · Max PV input: 180 kW\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-120K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e125 kW three-phase string inverter, a small step up on the same frame\u003c\/h3\u003e\u003cp\u003eAt 125 kW the apparent power climbs to 135 kVA and rated output current to 189.4 A, while the panel ceiling rises to 187.5 kW. That extra 7.5 kW of array headroom over the 120 kW unit is the practical reason to choose it: you fit two or three more strings without buying a second inverter. Cabling, mounting frame and enclosure stay exactly the same.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 125 kW · Max apparent power: 135 kVA · Rated output current: 189.4 A · Max PV input: 187.5 kW\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-125K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e130 kW three-phase inverter for a 195 kW array on one connection\u003c\/h3\u003e\u003cp\u003eThe 130 kW takes up to 195 kW of panels and runs a rated output current of 197 A. Its 204.6 A maximum output current and 135 kVA apparent power are shared with the 125 kW and 135 kW units, so the real gain is 7.5 kW more array than the 125 kW model on identical AC hardware. That suits a site where roof space is the limit rather than the grid connection.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 130 kW · Rated output current: 197 A · Max PV input: 195 kW · Max apparent power: 135 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-130K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e135 kW three-phase inverter that runs at its own current ceiling\u003c\/h3\u003e\u003cp\u003eAt 135 kW the rated output current and the maximum output current are the same number, 204.6 A, so the unit works at the top of its 135 kVA rating continuously instead of holding a reserve. Panel input goes to 202.5 kW. Size the AC breaker and cable for 204.6 A on this model, not for a lower rated figure, because on this one the two values are identical.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 135 kW · Rated output current: 204.6 A · Max PV input: 202.5 kW · Max apparent power: 135 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-135K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e136 kW three-phase inverter, the largest rating in the AM8 range\u003c\/h3\u003e\u003cp\u003eThe 136 kW sits at the top of the family and is the only one rated 136 kVA, with rated and maximum output current both at 206.1 A. It carries up to 204 kW of panels, the largest array allowance here. Choose it when your grid connection can take 206.1 A per phase and you want every kilowatt the chassis offers. The 135 kW model gives up 1.5 kW of array for almost the same current.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 136 kW · Max apparent power: 136 kVA · Max AC output current: 206.1 A · Max PV input: 204 kW\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-136K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 5 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Injection (%)\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Full Load Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e550-850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e8\/4+4+4+4+4+4+4+4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Ocp (A)\u003c\/td\u003e\n\u003ctd\u003e398\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232 \/WiFi\/LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e1006 x 516 x 325.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"120 kW","offer_id":47869739466857,"sku":"SUN-120K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true},{"title":"125 kW","offer_id":47869739499625,"sku":"SUN-125K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true},{"title":"130 kW","offer_id":47869739532393,"sku":"SUN-130K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true},{"title":"135 kW","offer_id":47869739565161,"sku":"SUN-135K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true},{"title":"136 kW","offer_id":47869739597929,"sku":"SUN-136K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-120-136K-G01P3.png?v=1785851372"},{"product_id":"deye-sun-g05-p3","title":"Deye 15–25 kW Three-Phase Solar Inverter","description":"\u003cp\u003eThe SUN-G05 is Deye's three-phase string inverter for roofs that sell power to the grid rather than store it, from a 15 kW shop roof up to a 25 kW warehouse array. Every rating runs two independent MPPT trackers and holds 98% European efficiency, so the choice comes down to how many panels you have and how much current your board can carry. Pick by array size first, then check the output current against your existing supply.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo independent MPPT trackers on every rating, so a roof split across two pitches runs as two separate strings\u003c\/li\u003e\n\u003cli\u003e98% European efficiency across the whole range, the weighted figure that reflects a real day rather than one peak moment\u003c\/li\u003e\n\u003cli\u003eIP65 sealing lets the unit sit outdoors on a wall, and it keeps working from -25°C to 60°C\u003c\/li\u003e\n\u003cli\u003eCurrent distortion stays under 3% THDi, which is what most utilities ask for on a three-phase connection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e15 kW three-phase string inverter for a small commercial rooftop\u003c\/h3\u003e\u003cp\u003eThe 15 kW is the odd one in this range and the quietest, running under 40 dB where the rest sit at 50 dB. Its two trackers are not matched: one takes 13 A and the other 26 A, and the string ceiling is 1000 V rather than the 1100 V the bigger units allow. You can fit 19.5 kW of panels to it, and it returns 22.7 A per phase at rated output with 16.5 kVA available.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax efficiency: 98.5% · Panel headroom: 19.5 kW · Max string voltage: 1,000 V · Noise: under 40 dB\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-15K-G05\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e18 kW three-phase solar inverter for a 23 kW rooftop panel array\u003c\/h3\u003e\u003cp\u003eStep up from the 15 kW and both trackers take 26 A each, so 23.4 kW of panels can go on the roof and strings may run to 1100 V. It gives 27.3 A per phase at its rated 18 kW, with 19.8 kVA at the ceiling, which is the usual sizing for a workshop or a small hotel. The array needs to reach 500 V before the inverter will hold full output.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanel headroom: 23.4 kW · Max apparent power: 19.8 kVA · Rated output current: 27.3 A per phase · Full-output PV window: 500-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-18K-G05\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e20 kW three-phase grid-tie inverter for a mid-size factory roof\u003c\/h3\u003e\u003cp\u003eIt takes the same 28.6 kW of panels as the 22 kW model but carries a lower AC rating, which makes it the one to pick when the array is generous and the grid connection is not. Rated output is 30.3 A per phase, rising to 22 kVA of apparent power. Its full-output window opens at 500 V, the same as the 18 kW, so a string layout can be copied straight across from that unit.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanel headroom: 28.6 kW · Max apparent power: 22 kVA · Rated output current: 30.3 A per phase · Full-output PV window: 500-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-20K-G05\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e22 kW three-phase string inverter sized for a 28.6 kW solar array\u003c\/h3\u003e\u003cp\u003eThe 22 kW accepts the same 28.6 kW of panels as the 20 kW but converts more of it, giving 33.4 A per phase and 24.2 kVA. Its full-output window starts higher, at 550 V, so strings need an extra module or two compared with a 20 kW build to keep it at rated power through the middle of the day. A sensible choice where the roof is already full and the supply can carry the extra current.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanel headroom: 28.6 kW · Max apparent power: 24.2 kVA · Rated output current: 33.4 A per phase · Full-output PV window: 550-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-22K-G05\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e23 kW three-phase solar inverter for a large warehouse rooftop\u003c\/h3\u003e\u003cp\u003eA narrow step above the 22 kW: 29.9 kW of panels instead of 28.6 kW, and 34.9 A per phase instead of 33.4 A. Peak AC output reaches 38.4 A with 25.3 kVA of apparent power. It shares the 22 kW model's 550 V full-output threshold, so a string design carries over from that unit unchanged, and the extra 1.3 kW of panel headroom is what you are actually buying.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanel headroom: 29.9 kW · Max apparent power: 25.3 kVA · Rated output current: 34.9 A per phase · Peak AC current: 38.4 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-23K-G05\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e25 kW three-phase string inverter, the largest G05 on the shelf\u003c\/h3\u003e\u003cp\u003eThe biggest G05 here takes 32.5 kW of panels, close to 40% more than the 18 kW, and returns 37.9 A per phase at its rated 25 kW. Apparent power tops out at 27.5 kVA and peak AC current at 41.7 A, so the outgoing breaker and cable want sizing against that figure, not against the 25 kW on the label. It suits a full factory or warehouse roof on a three-phase supply.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanel headroom: 32.5 kW · Max apparent power: 27.5 kVA · Rated output current: 37.9 A per phase · Peak AC current: 41.7 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-25K-G05\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 6 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\/45Hz-55Hz, 60Hz\/55Hz-65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380,230\/400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC),OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eDC Injection Current: \u0026lt;0.5%In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"15 kW","offer_id":47869739794537,"sku":"DEYE-SUN-15K-G05","price":6399.0,"currency_code":"AED","in_stock":true},{"title":"18 kW","offer_id":47869739827305,"sku":"DEYE-SUN-18K-G05","price":8750.0,"currency_code":"AED","in_stock":true},{"title":"20 kW","offer_id":47869739860073,"sku":"DEYE-SUN-20K-G05","price":8750.0,"currency_code":"AED","in_stock":true},{"title":"22 kW","offer_id":47869739892841,"sku":"DEYE-SUN-22K-G05","price":8750.0,"currency_code":"AED","in_stock":true},{"title":"23 kW","offer_id":47869739925609,"sku":"DEYE-SUN-23K-G05","price":8750.0,"currency_code":"AED","in_stock":true},{"title":"25 kW","offer_id":47869739958377,"sku":"DEYE-SUN-25K-G05","price":8750.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-15K-G05.png?v=1785851378"},{"product_id":"deye-sun-g04-lv-p3","title":"Deye 18–21 kW Three-Phase Low-Voltage Solar Inverter","description":"\u003cp\u003eThese are three-phase solar inverters for low-voltage grids, the 127\/220 V and 133\/230 V supplies used in parts of Latin America and on older industrial sites. All three run at 98.6% peak efficiency with two independent MPPT trackers, so a roof split across two orientations still gets tracked properly. The choice between 18, 20 and 21 kW comes down to array size and, in one case, the size of the box going on the wall.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e98.6% peak efficiency and a 98.1% European weighted average at every rating.\u003c\/li\u003e\n\u003cli\u003eTwo independent MPPT trackers with a 200 to 700 V window and 40 A per input.\u003c\/li\u003e\n\u003cli\u003eWakes at 250 V and takes up to 800 V from the array.\u003c\/li\u003e\n\u003cli\u003eIP65 sealed and rated from -25 to 65 C, so an outdoor wall in real heat is fine.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e18 kW three-phase LV inverter with a 250 V full-load MPPT floor\u003c\/h3\u003e\u003cp\u003eRated 18 kW with room for 27 kW of panels and 47.3 A per phase. Its useful trick is the full-load MPPT window, which starts at 250 V rather than the 300 V of the 20 and 21 kW units, so it holds full output on a shorter string or on a cold, overcast morning. Maximum output fault current is 90.4 A. The cabinet weighs 51.9 kg.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 18 kW · Max PV input power: 27 kW · Max AC output current: 47.3 A · Full-load MPPT range: 250-700 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-18K-G04-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e20 kW three-phase low-voltage inverter for a 30 kW rooftop array\u003c\/h3\u003e\u003cp\u003eRated 20 kW and taking up to 30 kW of panels, with 52.5 A per phase. Its full-load MPPT window starts at 300 V, so it expects a longer string than the 18 kW model. Maximum output fault current is 100.4 A, which is the number your electrician needs when sizing the AC protection. It uses the same 51.9 kg cabinet as the 18 kW unit, so the mounting is identical.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 20 kW · Max PV input power: 30 kW · Max AC output current: 52.5 A · Max output fault current: 100.4 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-20K-G04-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e21 kW three-phase LV solar inverter in a lighter 23 kg cabinet\u003c\/h3\u003e\u003cp\u003eThe largest of the three, rated 21 kW with 31.5 kW of panel capacity and 55.2 A per phase. It is also the odd one out physically: 23 kg in a 362 x 577 x 215 mm case, against 51.9 kg and 456 x 750 x 268.5 mm for the 18 and 20 kW units. That changes what two people can lift onto a wall unaided. Maximum output fault current is 105.4 A.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 21 kW · Max PV input power: 31.5 kW · Max AC output current: 55.2 A · Weight: 23 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-21K-G04-LV\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 3 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFCI Protection\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e2\/3+3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNBR 16149, NBR 16150, EN 50549, RD 140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC),OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\/45Hz-55Hz, 60Hz\/55Hz-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC),TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD1602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e28.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e330 x 572 x 206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eDC Injection Current: \u0026lt;0.5%In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"18 kW","offer_id":47869740023913,"sku":"DEYE-SUN-18K-G04-LV","price":7350.0,"currency_code":"AED","in_stock":true},{"title":"20 kW","offer_id":47869740056681,"sku":"DEYE-SUN-20K-G04-LV","price":7350.0,"currency_code":"AED","in_stock":true},{"title":"21 kW","offer_id":47869740089449,"sku":"DEYE-SUN-21K-G04-LV","price":7350.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-18-21K-G04-LV.png?v=1785851380"},{"product_id":"deye-sun-g05p1-eu-am2","title":"Deye 3.6–6.2 kW Single-Phase Solar Inverter","description":"\u003cp\u003eA single-phase solar inverter for a house, a villa or a small shop on a normal 230 V supply. All eight ratings sit in the same small 7.7 kg case, so the size you pick is decided by how many panels are going on the roof and what the utility lets you export. There is no battery here: sunlight goes to the loads first, and the rest to the grid.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo independent trackers with a 70 to 500 V window and 18 A per string, so two roof faces can share one inverter\u003c\/li\u003e\n\u003cli\u003eWakes up at 80 V, so it starts making a little power early in the morning and keeps going late\u003c\/li\u003e\n\u003cli\u003e7.7 kg in a 305 x 280 x 180 mm case, light enough for one person to lift onto the bracket\u003c\/li\u003e\n\u003cli\u003eNo fan: natural cooling keeps it under 35 dB, and IP65 lets it live outdoors at up to 3,000 m\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3.6 kW single-phase inverter for a small home roof, 4.7 kW of panels\u003c\/h3\u003e\u003cp\u003eThe smallest of the eight, sized for a modest house roof. It takes 4.7 kW of panels and puts out 3.96 kVA, up to 18 A on the AC side and 16.4 A at the rated point. Deye rates it at 97.3% peak efficiency and 96.9% European efficiency, marginally below its bigger siblings. It is the one to pick where the export limit or the meter caps you near 3.6 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 3.6 kW · Max PV input: 4.7 kW · Max AC output current: 18 A · Max efficiency: 97.3%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3.6K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e4 kW single-phase solar inverter for a 5.2 kW rooftop array\u003c\/h3\u003e\u003cp\u003eA round 4 kW rating that suits a typical family house with about a dozen panels. It carries 5.2 kW of panels, 4.4 kVA of apparent power and 20 A maximum on the AC side, with 18.2 A at the rated point. European efficiency is quoted at 96.9%. Choose it over the 3.6 kW when the roof has room for another string but the supply is still a standard single-phase connection.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 4 kW · Max PV input: 5.2 kW · Max AC output current: 20 A · Apparent power: 4.4 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-4K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e4.2 kW single-phase inverter, 5.5 kW of panels and 97% Euro efficiency\u003c\/h3\u003e\u003cp\u003eA 4.2 kW rating that exists mainly for grid rules that cap export just above 4 kW. It accepts 5.5 kW of panels, delivers 4.62 kVA and reaches 21 A on the AC side, with 19.1 A rated. Only the 3.6 kW sits lower, at 97.3% peak; from 4 kW upward Deye quotes 97.5% peak and 97.0% European efficiency.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 4.2 kW · Max PV input: 5.5 kW · Max AC output current: 21 A · Euro efficiency: 97.0%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-4.2K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e4.6 kW single-phase inverter for a 6 kW roof under a 5 kW export cap\u003c\/h3\u003e\u003cp\u003eThe 4.6 kW is the common answer where a utility allows a little under 5 kW of export. It takes a full 6 kW of panels, gives 5.06 kVA and tops out at 23 A on the AC side, with 21 A at the rated point. Peak efficiency is 97.5%. Because 6 kW of panels against 4.6 kW of output is a healthy oversize, it holds full output for longer through the middle of the day.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 4.6 kW · Max PV input: 6 kW · Max AC output current: 23 A · Apparent power: 5.06 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-4.6K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5 kW single-phase solar inverter for a 6.5 kW home array\u003c\/h3\u003e\u003cp\u003eThe most asked for size in the range: 5 kW of output for a family house with air conditioning. It handles 6.5 kW of panels, 5.5 kVA of apparent power and 25 A maximum on the AC side, with 22.8 A at the rated point, so the AC circuit has to be sized for it. Peak efficiency is 97.5%, and it still weighs the same 7.7 kg as the 3.6 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 5 kW · Max PV input: 6.5 kW · Max AC output current: 25 A · Apparent power: 5.5 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5.2 kW single-phase inverter, 6.8 kW of panels and 26 A output\u003c\/h3\u003e\u003cp\u003eA 5.2 kW step for roofs that came out slightly larger than a 5 kW design. It accepts 6.8 kW of panels, gives 5.72 kVA and reaches 26 A on the AC side against 23.7 A at the rated point. Everything else, from the two trackers to the 550 V string limit, matches the 5 kW, so the extra 300 W of panel capacity is the only practical gain.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 5.2 kW · Max PV input: 6.8 kW · Max AC output current: 26 A · Rated AC current: 23.7 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5.2K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW single-phase inverter for a large villa roof, 7.8 kW of panels\u003c\/h3\u003e\u003cp\u003eA 6 kW unit for a large villa or a shop that runs through the afternoon. It takes 7.8 kW of panels, 6.6 kVA of apparent power and 30 A maximum on the AC side, with 27.3 A rated, which is enough current that the AC cable and breaker need checking before install. It still cools itself with no fan and still weighs 7.7 kg.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 6 kW · Max PV input: 7.8 kW · Max AC output current: 30 A · Apparent power: 6.6 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6.2 kW single-phase inverter, the biggest in Deye's G05P1 range\u003c\/h3\u003e\u003cp\u003eThe largest single-phase unit here, for the roof that has run out of space rather than ambition. It carries 8.1 kW of panels, 6.82 kVA and 31 A maximum on the AC side, with 28.2 A at the rated point. Past this size Deye's answer is a three-phase machine, so if the property has three phases available it is worth comparing before ordering.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 6.2 kW · Max PV input: 8.1 kW · Max AC output current: 31 A · Rated AC current: 28.2 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6.2K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 8 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e70-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e2\/1+1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e80-550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232 \/WiFi\/LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Operating Current (A)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eNatural cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to +60℃, \u0026gt;45℃ Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e7.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e305 x 280 x 180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"3.6 kW","offer_id":47869740286057,"sku":"SUN-3.6K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"4 kW","offer_id":47869740318825,"sku":"SUN-4K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"4.2 kW","offer_id":47869740351593,"sku":"SUN-4.2K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"4.6 kW","offer_id":47869740384361,"sku":"SUN-4.6K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"5 kW","offer_id":47869740417129,"sku":"SUN-5K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"5.2 kW","offer_id":47869740449897,"sku":"SUN-5.2K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869740482665,"sku":"SUN-6K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"6.2 kW","offer_id":47869740515433,"sku":"SUN-6.2K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-3.6-6.2K-G05P1.png?v=1785851385"},{"product_id":"deye-sun-g04-p3","title":"Deye 30–50 kW Three-Phase Solar Inverter","description":"\u003cp\u003eThe Deye G04 three-phase solar inverter is a grid-tied machine for commercial roofs: it turns panel output into 400 V three-phase power and feeds it straight into the building, with no battery involved. Seven ratings run from 30 kW to 50 kW, and the practical difference between them is how much panel each one can take and how many separate roof faces it can track independently.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEuropean weighted efficiency of 98.1% on every rating in the group\u003c\/li\u003e\n\u003cli\u003eStrings up to 1,100 V, tracked anywhere between 200 V and 1,000 V\u003c\/li\u003e\n\u003cli\u003eStarts producing from 250 V and holds current distortion below 3%\u003c\/li\u003e\n\u003cli\u003eIP65 enclosure rated from -25 C to 60 C for rooftop or plant-room mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e30 kW three-phase grid-tied solar inverter for a 45 kW commercial roof\u003c\/h3\u003e\u003cp\u003eThe entry point of the G04 line takes up to 45 kW of panel against a 30 kW output, a 1.5 times oversize that only the 36 kW model matches. Two independent inputs of 40 A each let you split the array across two roof faces. It puts out 33 kVA and 50 A per phase, peaks at 98.6% efficiency, and weighs 23 kg.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 45 kW · PV inputs: 2 x 40 A · Max AC output current: 50 A · Weight: 23 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-30K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e33 kW three-phase solar inverter, 42.9 kW panel input, two trackers\u003c\/h3\u003e\u003cp\u003eThe 33 kW and the 35 kW share a datasheet column, so their output currents are quoted together rather than separately. What clearly separates them is the array: this one is specified for 42.9 kW of panel, 2.6 kW less than the 35 kW. Two 40 A inputs, full output from 500 V upward, 98.6% peak efficiency, and an altitude rating of 4,000 m for highland sites.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 42.9 kW · PV inputs: 2 x 40 A · Full-load tracking window: 500 to 850 V · Max altitude: 4,000 m\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-33K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e35 kW three-phase solar inverter with 45.5 kW of panel input allowed\u003c\/h3\u003e\u003cp\u003eTwo extra kilowatts of output over the 33 kW, and 45.5 kW of panel rather than 42.9 kW. Deye publishes one shared current column for the two models, so we do not quote a separate output current here; the honest difference is rated power and array size. A 23 kg wall case, a pair of 40 A inputs, a 4,000 m altitude rating and 98.6% peak efficiency.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 45.5 kW · PV inputs: 2 x 40 A · Weight: 23 kg · Max efficiency: 98.6%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-35K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e36 kW three-phase solar inverter, 54 kW panel input on two trackers\u003c\/h3\u003e\u003cp\u003eThis is the last of the two-tracker frames and carries the most panel of that group: 54 kW feeding a 36 kW output. Useful on east and west roofs where neither side peaks at once. It delivers 39.6 kVA and 60 A per phase from a 23 kg case, and holds full output from 500 V upward. Fault current is quoted at 104.4 A, which your protection device needs to clear.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 54 kW · Max apparent power: 39.6 kVA · Max AC output current: 60 A · PV inputs: 2 x 40 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-36K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e40 kW three-phase solar inverter with three MPP trackers, 98.7% peak\u003c\/h3\u003e\u003cp\u003eA third independent PV input arrives at 40 kW, so the array can be split three ways across roofs facing different directions without losing yield on the shaded one. Peak efficiency also rises to 98.7%. Output is 44 kVA and 66.7 A per phase, panel input is capped at 52 kW, and the unit runs under 50 dB, quiet enough for a plant room next to offices. It weighs 37.1 kg.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 52 kW · PV inputs: 3 x 40 A · Max AC output current: 66.7 A · Noise: under 50 dB\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-40K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e45 kW three-phase solar inverter, 58.5 kW panel, three MPP trackers\u003c\/h3\u003e\u003cp\u003eThree 40 A inputs again, but a much larger frame: 698 by 613 by 236.5 mm and 53.7 kg, the same weight as the 33 kW. It accepts 58.5 kW of panel, gives 49.5 kVA and 75 A per phase, and holds 98.7% peak efficiency. Check the wall or frame it goes on before ordering, because the extra 16.6 kg over the 40 kW changes the fixing.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 58.5 kW · PV inputs: 3 x 40 A · Max AC output current: 75 A · Weight: 53.7 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-45K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e50 kW three-phase solar inverter with four MPP trackers, 65 kW panel\u003c\/h3\u003e\u003cp\u003eThe largest rating is the only one with four separate 40 A PV inputs, which suits a site with several roof pitches or a car park canopy in sections. It takes 65 kW of panel, the most in the range, and returns 55 kVA and 83.3 A per phase at up to 98.7% efficiency. Fault current is 145 A, so size the AC protection and cable accordingly.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 65 kW · PV inputs: 4 x 40 A · Max AC output current: 83.3 A · Max apparent power: 55 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-50K-G04\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 7 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIECUNE61727,217002,IEC62116,OVE-RichtlinieCEI0-21, ENR25,50549,G99,VDE-AR-NNRS097,RD4105140,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC),OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC),TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"30 kW","offer_id":47869740941417,"sku":"DEYE-SUN-30K-G04","price":3963.0,"currency_code":"AED","in_stock":true},{"title":"33 kW","offer_id":47869740974185,"sku":"DEYE-SUN-33K-G04","price":3963.0,"currency_code":"AED","in_stock":true},{"title":"35 kW","offer_id":47869741006953,"sku":"DEYE-SUN-35K-G04","price":3963.0,"currency_code":"AED","in_stock":true},{"title":"36 kW","offer_id":47869741039721,"sku":"DEYE-SUN-36K-G04","price":3963.0,"currency_code":"AED","in_stock":true},{"title":"40 kW","offer_id":47869741072489,"sku":"DEYE-SUN-40K-G04","price":5689.0,"currency_code":"AED","in_stock":true},{"title":"45 kW","offer_id":47869741105257,"sku":"DEYE-SUN-45K-G04","price":5689.0,"currency_code":"AED","in_stock":true},{"title":"50 kW","offer_id":47869741138025,"sku":"DEYE-SUN-50K-G04","price":5689.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-30-36K-G04.png?v=1785851393"},{"product_id":"deye-sun-g04p3-eu-am4-lv","title":"Deye 33–50 kW Three-Phase Low-Voltage Solar Inverter","description":"\u003cp\u003eThis is Deye's three-phase string inverter for low-voltage grids: the 127\/220 V and 133\/230 V supplies found in Brazil and other markets that never moved to 400 V. Five ratings run from 33 kW to 50 kW, all grid-tied with no battery attached, all with four independent solar inputs. The rating decides the array, because Deye allows 1.5 times the AC power in panels on every model here.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGrid side is 127\/220 V or 133\/230 V three-phase, certified to NBR 16149, NBR 16150 and EN 50549\u003c\/li\u003e\n\u003cli\u003eFour independent solar inputs, 40 A each, tracking 200 to 700 V under an 800 V ceiling\u003c\/li\u003e\n\u003cli\u003ePanels can be oversized to 1.5 times the AC rating on every model in the range\u003c\/li\u003e\n\u003cli\u003eIP65 enclosure, air cooled, 53.7 kg, rated to 65 °C ambient with derating above 45 °C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e33 kW three-phase string inverter for a 220V commercial rooftop\u003c\/h3\u003e\u003cp\u003eThe entry point of the range and the cheapest way into four-tracker solar on a 220 V grid. It puts out 86.7 A per phase and accepts 49.5 kW of panels, at a peak efficiency of 98.6%. Fits a warehouse or supermarket roof where the load runs through daylight hours and nobody plans to add batteries later.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 33 kW · Max AC output current: 86.7 A · Max PV input power: 49.5 kW · Peak efficiency: 98.6%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-33K-G04P3-EU-AM4-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e35 kW three-phase string inverter, 52.5 kW of panels on a 220V grid\u003c\/h3\u003e\u003cp\u003eA 2 kW step over the 33 kW that buys 3 kW more panel headroom, 52.5 kW in total, and 91.9 A per phase at the output. Peak efficiency stays at 98.6%; the 98.7% figure only starts at 40 kW. Choose this one when the roof came out slightly larger than the 33 kW would carry and you would rather not move up a whole size.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 35 kW · Max AC output current: 91.9 A · Max PV input power: 52.5 kW · Peak efficiency: 98.6%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-35K-G04P3-EU-AM4-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e40 kW three-phase string inverter for a factory roof on a 220V grid\u003c\/h3\u003e\u003cp\u003eFirst rating in the range to reach 98.7% peak efficiency, a tenth of a point above the 33 kW and 35 kW. It delivers 105 A per phase and takes 60 kW of panels. At this size the AC cable run and the site's main breaker matter as much as the inverter itself, so have the run sized before you order.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 40 kW · Max AC output current: 105 A · Max PV input power: 60 kW · Peak efficiency: 98.7%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-40K-G04P3-EU-AM4-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e45 kW three-phase string inverter, 67.5 kW array on 127\/220V supply\u003c\/h3\u003e\u003cp\u003eSits between the 40 kW and the 50 kW, and it exists for roofs that overshoot 60 kW of panels without reaching 75 kW. Output is 118.2 A per phase at 98.7% peak efficiency, with 67.5 kW the most PV Deye allows on it. Same cabinet and the same four 40 A inputs as every other rating here, so the only planning change is cable size.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 45 kW · Max AC output current: 118.2 A · Max PV input power: 67.5 kW · Peak efficiency: 98.7%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-45K-G04P3-EU-AM4-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e50 kW three-phase string inverter, the largest LV model at 75 kW PV\u003c\/h3\u003e\u003cp\u003eThe largest in the range: 131.3 A per phase and 75 kW of panels, still on four inputs of 40 A each, still at 98.7% peak efficiency. On a 220 V grid that is a great deal of current out of one machine, so the AC side wants proper sizing and a short run to the board. It is the top of this low-voltage range.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 50 kW · Max AC output current: 131.3 A · Max PV input power: 75 kW · Peak efficiency: 98.7%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-50K-G04P3-EU-AM4-LV\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 5 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Ocp (A)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNBR 16149, NBR 16150, EN 50549, RD 140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V 0.85UN-1.1UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e53.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e698 x 613 x 236.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eDC Injection Current: \u0026lt;0.5%In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"33 kW","offer_id":47869741170793,"sku":"SUN-33K-G04P3-EU-AM4-LV","price":15000.0,"currency_code":"AED","in_stock":true},{"title":"35 kW","offer_id":47869741203561,"sku":"SUN-35K-G04P3-EU-AM4-LV","price":15000.0,"currency_code":"AED","in_stock":true},{"title":"40 kW","offer_id":47869741236329,"sku":"SUN-40K-G04P3-EU-AM4-LV","price":15000.0,"currency_code":"AED","in_stock":true},{"title":"45 kW","offer_id":47869741269097,"sku":"SUN-45K-G04P3-EU-AM4-LV","price":15000.0,"currency_code":"AED","in_stock":true},{"title":"50 kW","offer_id":47869741301865,"sku":"SUN-50K-G04P3-EU-AM4-LV","price":15000.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-33-50K-G04P3-LV.png?v=1785851395"},{"product_id":"deye-sun-g01p3-eu-am8-lv","title":"Deye 60–75 kW Three-Phase Low-Voltage Solar Inverter","description":"\u003cp\u003eMost commercial three-phase inverters expect a 380 V or 400 V grid. This low-voltage three-phase solar inverter is built for the networks that run at 127\/220 V or 133\/230 V instead, which covers Brazil and much of Latin America. Three ratings, 60 kW, 70 kW and 75 kW, share one 103 kg body, eight tracker inputs and a 200 V to 700 V tracking window.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutput at 127\/220 V or 133\/230 V, certified to NBR 16149, NBR 16150 and EN 50549.\u003c\/li\u003e\n\u003cli\u003eEight tracker inputs taking 40 A each, with an 800 V ceiling on the panel strings.\u003c\/li\u003e\n\u003cli\u003e98.2% European efficiency and better than 99% tracking efficiency on all three ratings.\u003c\/li\u003e\n\u003cli\u003eRuns at 55 dB or below, sealed to IP65, and rated to 60°C ambient and 4,000 m altitude.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e60 kW low-voltage inverter for a 90 kW array on a 220 V grid\u003c\/h3\u003e\u003cp\u003eThe 60 kW has the widest tracking window of the three: it holds full output from 290 V upward, against 330 V on the 70 kW and 360 V on the 75 kW. Shorter strings still make full power, which helps on a broken-up roof with several small planes. Output is 157.5 A per phase at 60 kVA, and the array can reach 90 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 60 kW · Full-load tracking window: 290 to 700 V · Max AC output current: 157.5 A · Max PV input: 90 kW\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-60K-G01P3-EU-AM8-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e70 kW three-phase low-voltage inverter for 105 kW of solar panels\u003c\/h3\u003e\u003cp\u003eThe 70 kW sits in the middle of the family: 183.8 A per phase, 70 kVA of apparent power, and up to 105 kW of panels. Full output needs at least 330 V from the string, so plan longer strings than the 60 kW model would need. Maximum output fault current is 351 A, and that is the number the protection device on the AC side has to clear.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 70 kW · Full-load tracking window: 330 to 700 V · Max AC output current: 183.8 A · Max output fault current: 351 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-70K-G01P3-EU-AM8-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e75 kW low-voltage inverter, the largest in the 127\/220 V range\u003c\/h3\u003e\u003cp\u003eThe 75 kW is the top rating here, at 196.9 A per phase and 75 kVA. It takes 112.5 kW of panels, 22.5 kW more than the 60 kW model inside the same enclosure, which is the simplest way to add array on a site short of wall space. It needs 360 V or more from each string to hold full output, the narrowest window of the three, so plan the string lengths carefully.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 75 kW · Full-load tracking window: 360 to 700 V · Max AC output current: 196.9 A · Max PV input: 112.5 kW\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-75K-G01P3-EU-AM8-LV\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 3 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Voltage Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Short Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFCI Protection\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Over Current Protection (A)\u003c\/td\u003e\n\u003ctd\u003e398\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e8\/4+4+4+4+4+4+4+4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNBR 16149, NBR 16150, EN 50549, RD 140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e1006 x 516 x 325.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eDC Injection Current: \u0026lt;0.5%ln\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"60 kW","offer_id":47869741564009,"sku":"SUN-60K-G01P3-EU-AM8-LV","price":22500.0,"currency_code":"AED","in_stock":true},{"title":"70 kW","offer_id":47869741596777,"sku":"SUN-70K-G01P3-EU-AM8-LV","price":22500.0,"currency_code":"AED","in_stock":true},{"title":"75 kW","offer_id":47869741629545,"sku":"SUN-75K-G01P3-EU-AM8-LV","price":22500.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-60-75K-G01P3-LV.png?v=1785851401"},{"product_id":"deye-sun-g04p3-eu-am4","title":"Deye 60–80 kW Three-Phase Solar Inverter","description":"\u003cp\u003eA three-phase solar inverter of this size goes on the wall of a factory, a cold store or a school and sends the whole roof straight into the building's own supply. Four ratings share one 53.7 kg cabinet, so the frame, the cabling method and the spares stay the same whichever one is specified. Panels connect at up to 1,100 V, which keeps string counts and cable runs down on a large roof.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOne 53.7 kg cabinet across all four ratings, IP65 sealed and fan cooled at 55 dB or less\u003c\/li\u003e\n\u003cli\u003ePanel input to 1,100 V with tracking from 200 V, so long strings are allowed\u003c\/li\u003e\n\u003cli\u003eRated to 4,000 m altitude and ambient temperatures of -25 to 60 degrees C\u003c\/li\u003e\n\u003cli\u003eThree-phase 220\/380 V or 230\/400 V connection, wired 3L\/N\/PE\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e60 kW three-phase inverter for a mid-size commercial roof\u003c\/h3\u003e\u003cp\u003eThe smallest of the four, rated 60,000 W with 66,000 VA available and 90.9 A per phase. Its efficiency sits a shade below its siblings, at 98.6% peak and 98.0% European weighted. It holds full output from 490 V upward on the tracker, the widest window in the group, which leaves the string designer the most room. Panel input is capped at 90,000 W, half as much again as the AC rating.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 60,000 W · Max efficiency: 98.6% · Max PV input: 90,000 W · Full-load tracker window: 490-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-60K-G04P3-EU-AM4\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e70 kW three-phase inverter carrying 105 kW of panels on one unit\u003c\/h3\u003e\u003cp\u003eRated 70,000 W and 77,000 VA, giving 106.1 A per phase, with peak efficiency of 98.7% and 98.1% European weighted. Full output needs 570 V or more on the tracker. Panel input is capped at 105,000 W. Case, weight and altitude rating match the 60 kW exactly, so a site laid out for one takes the other with no change to the mounting or the cable entry.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 70,000 W · Max PV input: 105,000 W · Rated output current: 106.1 A · Full-load tracker window: 570-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-70K-G04P3-EU-AM4\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e75 kW three-phase inverter built around a 720 V string design\u003c\/h3\u003e\u003cp\u003eRated 75,000 W with 82,500 VA and 113.6 A per phase. This is the first of the four sized around a 720 V nominal panel voltage rather than 600 V, and it wants at least 610 V on the tracker to hold full output, so the strings are designed longer. Panel input is capped at 112,500 W. Peak efficiency is 98.7%, European weighted 98.1%.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 75,000 W · Nominal PV voltage: 720 V · Max PV input: 112,500 W · Full-load tracker window: 610-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-75K-G04P3-EU-AM4\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e80 kW three-phase inverter, the largest here at 120 kW of panels\u003c\/h3\u003e\u003cp\u003eThe biggest of the family at 80,000 W, 88,000 VA and 133.3 A per phase, and that current figure is the one to check against the incoming breaker and cable before ordering. Panels can total 120,000 W. Full output needs 650 V or more on the tracker, the narrowest window of the four. Efficiency is 98.7% peak and 98.1% European weighted, in the same 53.7 kg case.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 80,000 W · Max AC output current: 133.3 A · Max PV input: 120,000 W · Full-load tracker window: 650-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-80K-G04P3-EU-AM4\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 4 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e53.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e698 x 613 x 236.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"60 kW","offer_id":47869741662313,"sku":"SUN-60K-G04P3-EU-AM4","price":24000.0,"currency_code":"AED","in_stock":true},{"title":"70 kW","offer_id":47869741695081,"sku":"SUN-70K-G04P3-EU-AM4","price":24000.0,"currency_code":"AED","in_stock":true},{"title":"75 kW","offer_id":47869741727849,"sku":"SUN-75K-G04P3-EU-AM4","price":24000.0,"currency_code":"AED","in_stock":true},{"title":"80 kW","offer_id":47869741760617,"sku":"SUN-80K-G04P3-EU-AM4","price":24000.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-60-80K-G04P3.png?v=1785851403"},{"product_id":"deye-sun-g06-lv-p3","title":"Deye 6–8 kW Three-Phase Low-Voltage Solar Inverter","description":"\u003cp\u003eThe 6 kW and 8 kW models here are three-phase solar inverters made for low-voltage grids running at 127\/220 V or 133\/230 V. Both are 11 kg wall units with two MPPT trackers and no fan, which makes them practical over a shop counter or in a small workshop where nobody wants a noisy box overhead. The difference between the two is mainly how much panel each one will swallow.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBoth weigh 11 kg in a 283 x 463 x 178 mm case, so the same pair of bolts holds either one.\u003c\/li\u003e\n\u003cli\u003eTwo MPPT trackers with a 200 to 700 V window and a 300 to 700 V full-load band.\u003c\/li\u003e\n\u003cli\u003eWakes at 250 V and accepts up to 800 V from the array.\u003c\/li\u003e\n\u003cli\u003eIP65 sealed with natural cooling, meaning no fan to clog with dust.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e6 kW three-phase solar inverter for a 7.8 kW shop or villa array\u003c\/h3\u003e\u003cp\u003eRated 6 kW with 7,800 W of panel capacity and 15.8 A per phase. Both of its trackers take 20 A, so the array wants splitting fairly evenly between them. European weighted efficiency is 97.8% and maximum output fault current is 30.2 A. Pick this one when the roof is a single clean plane and the load is lighting, fans and a couple of small motors.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 6 kW · Max PV input power: 7,800 W · Max AC output current: 15.8 A · European efficiency: 97.8%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-G06-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW three-phase solar inverter with 20 A and 26 A MPPT inputs\u003c\/h3\u003e\u003cp\u003eRated 8 kW and taking 10,400 W of panels, with 21 A per phase. Its two trackers are deliberately unequal, 20 A on one and 26 A on the other, which lets you hang a longer string on the bigger input instead of splitting the roof down the middle. European weighted efficiency is 98%, a little ahead of the 6 kW model, and maximum output fault current is 40.2 A.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 8 kW · Max PV input power: 10,400 W · Max AC output current: 21 A · Max PV input current: 20 A + 26 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-G06-LV\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 2 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Ocp (A)\u003c\/td\u003e\n\u003ctd\u003e47.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Full Load Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e300-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNBR 16149, NBR 16150, EN 50549, RD 140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC),OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC),TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eNatural cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to +60℃,\u0026gt;45℃ derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e283 x 463 x 178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"6 kW","offer_id":47869741924457,"sku":"DEYE-SUN-6K-G06-LV","price":2800.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869741957225,"sku":"DEYE-SUN-8K-G06-LV","price":2800.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-6-8K-G06-LV.png?v=1785851408"},{"product_id":"sun-23-30k-g04-lv","title":"Deye 23–30 kW Three-Phase Low-Voltage Solar Inverter","description":"\u003cp\u003e\u003cstrong\u003e23-30 kW low-voltage three-phase inverter for a workshop or farm\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA three-phase low-voltage solar inverter built for grids that run at 127\/220 V or 133\/230 V rather than the 230\/400 V used in Europe and the Gulf, which is what the LV in the name refers to. It suits a workshop, a farm or a small commercial building of roughly 23 kW to 30 kW, feeding the building first and the grid after. Fitting a standard 400 V model to one of these supplies does not work, which is the reason this version exists.\u003c\/p\u003e\u003cp\u003eOne machine covering the 23 kW to 30 kW band on a 127\/220 V three-phase supply. Panels can reach 800 V, tracking runs from 200 V to 700 V and it needs 250 V on the strings before it starts producing. It weighs 37.1 kg in a 434 x 570 x 243 mm case and cools with a fan, so it sits at about 65 dB, better placed on a plant room wall than beside an office window. Five-year warranty.\u003c\/p\u003e\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power band\u003c\/td\u003e\n\u003ctd\u003e23-30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV input voltage\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT window\u003c\/td\u003e\n\u003ctd\u003e200-700 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e37.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power (W)\u003c\/td\u003e\n\u003ctd\u003e30000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V 0.85UN-1.1UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current (A)\u003c\/td\u003e\n\u003ctd\u003e78.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e4\/3+3+3+3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Power (W)\u003c\/td\u003e\n\u003ctd\u003e39000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Apparent Power (VA)\u003c\/td\u003e\n\u003ctd\u003e30000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Full Load Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNBR 16149, NBR 16150, EN 50549, RD 140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD1602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V 0.85UN-1.1UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e37.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to +60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e434 x 570 x 243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-23-30K-G04-LV\u003c\/small\u003e\u003c\/p\u003e","brand":"DEYE","offers":[{"title":"Default Title","offer_id":47869742383209,"sku":"DEYE-SUN-23-30K-G04-LV","price":10500.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-23-30K-G04-LV.png?v=1785851412"}],"url":"https:\/\/www.solarinstaller.ae\/collections\/string-inverters.oembed","provider":"Solar Installer","version":"1.0","type":"link"}