{"title":"Solar Inverters","description":"\u003cp\u003eEvery inverter across our brands, from small residential strings to commercial three-phase units.\u003c\/p\u003e","products":[{"product_id":"deye-sun-g04p1-eu-am1","title":"Deye 1–4 kW Single-Phase Solar Inverter","description":"\u003cp\u003eEvery model here is a single-phase solar inverter built for a house, a shop or a small workshop on a 220\/230 V supply. The range runs from 1 kW to 4 kW across ten steps, and all ten sit in the same 6.35 kg case, so sizing up costs nothing in wall space. They begin generating at 80 V, which means the array is working on weak morning light instead of waiting for full sun.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eThe same body at every rating: 6.35 kg, 280 x 310 x 184 mm, so the bracket and the wall space never change when you size up.\u003c\/li\u003e\n\u003cli\u003eStarts generating from 80 V, so the panels earn from first light rather than mid-morning.\u003c\/li\u003e\n\u003cli\u003eOne MPPT tracker, taking up to 550 V and 20 A from the array.\u003c\/li\u003e\n\u003cli\u003eSealed to IP65 and cooled by air alone at 35 dB or less, so it can hang on an outside wall with no fan to hear or clean.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e1 kW single-phase solar inverter for a cabin, kiosk or small shop\u003c\/h3\u003e\u003cp\u003eThe smallest step in the range, rated 1 kW and taking up to 1,300 W of panels, which is roughly two or three modern modules. Output tops out at 5 A, so it feeds an ordinary lighting and socket circuit without any switchboard work. Maximum efficiency is 97.3%, and the panel string is designed around a nominal 360 V.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 1 kW · Max PV input power: 1,300 W · Max AC output current: 5 A · Max efficiency: 97.3%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-1K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e1.5 kW single-phase solar inverter for a small flat or holiday home\u003c\/h3\u003e\u003cp\u003eRated 1.5 kW with room for 2,000 W of panels, this step suits a small flat or a weekend house where the daytime load is a fridge, a few fans and lighting. Maximum AC current is 7.5 A and apparent power 1,650 VA. Efficiency peaks at 97.3%, the same as the smaller unit, and the string is built around a nominal 360 V.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 1.5 kW · Max PV input power: 2,000 W · Max AC output current: 7.5 A · Max apparent power: 1,650 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-1.5K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e2 kW single-phase solar inverter to cover a home's daytime base load\u003c\/h3\u003e\u003cp\u003eAt 2 kW rated output and 2,600 W of panel capacity, this is the point where a household starts covering its own daytime running costs rather than just trimming them. It gives 10 A on the AC side and 2,200 VA of apparent power. Peak efficiency is 97.3% and the string sits around a nominal 360 V, so one row of panels does the job.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 2 kW · Max PV input power: 2,600 W · Max AC output current: 10 A · Max apparent power: 2,200 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-2K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e2.2 kW single-phase solar inverter for a 2.9 kW rooftop array\u003c\/h3\u003e\u003cp\u003eRated 2.2 kW and accepting 2,900 W of panels, this step exists for arrays that overshoot the 2 kW unit by a module or two. Maximum AC current is 11 A and apparent power 2,420 VA. Efficiency stays at 97.3% like the rest of the lower half of the range, and the string runs at a nominal 360 V.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 2.2 kW · Max PV input power: 2,900 W · Max AC output current: 11 A · Max apparent power: 2,420 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-2.2K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e2.5 kW single-phase solar inverter for a three-bedroom house roof\u003c\/h3\u003e\u003cp\u003eThis rating handles 3,300 W of panels against 2.5 kW of rated output, a comfortable ratio for a roof that loses sun late in the afternoon. Maximum AC current is 12.5 A and apparent power 2,750 VA. It keeps the 97.3% peak efficiency and the 360 V nominal string used by the smaller units in the family.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 2.5 kW · Max PV input power: 3,300 W · Max AC output current: 12.5 A · Max apparent power: 2,750 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-2.5K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e2.7 kW single-phase solar inverter for a 3.5 kW panel array\u003c\/h3\u003e\u003cp\u003eThe last of the 97.3% efficiency group, rated 2.7 kW and taking 3,500 W of panels. AC output reaches 13.5 A with 2,970 VA of apparent power. Take this over the 2.5 kW step when the array plan lands just past 3.3 kW of modules and you would rather not clip the peak on bright, cool days.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 2.7 kW · Max PV input power: 3,500 W · Max AC output current: 13.5 A · Max apparent power: 2,970 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-2.7K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e3 kW single-phase solar inverter, the common size for a family home\u003c\/h3\u003e\u003cp\u003eThe most-asked-for rating in the range, good for 3,900 W of panels against 3 kW of output. This is also where peak efficiency steps up to 97.5% from the 97.3% of the smaller units, so a little more of what the roof makes reaches the meter. Maximum AC current is 15 A and apparent power 3,300 VA, with the string still around a nominal 360 V.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 3 kW · Max PV input power: 3,900 W · Max AC output current: 15 A · Max efficiency: 97.5%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e3.3 kW single-phase solar inverter with a 420 V nominal panel string\u003c\/h3\u003e\u003cp\u003eRated 3.3 kW with 4,300 W of panel capacity and 97.5% peak efficiency. This is the first step whose string is designed around a nominal 420 V rather than 360 V, so it wants a longer run of panels in series than the smaller units and your layout has to allow for that. Maximum AC current is 16.5 A, apparent power 3,630 VA.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 3.3 kW · Max PV input power: 4,300 W · Max AC output current: 16.5 A · Rated PV input voltage: 420 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3.3K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e3.6 kW single-phase solar inverter for a villa roof, 4.7 kW of panels\u003c\/h3\u003e\u003cp\u003eRated 3.6 kW and accepting 4,700 W of panels, this suits a full villa roof where the array is deliberately oversized to hold output up through the middle of the day. Maximum AC current is 18 A and apparent power 3,960 VA. Peak efficiency is 97.5% and the panel string is built around a nominal 420 V.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 3.6 kW · Max PV input power: 4,700 W · Max AC output current: 18 A · Max apparent power: 3,960 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3.6K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e4 kW single-phase solar inverter, the top step before three-phase\u003c\/h3\u003e\u003cp\u003eThe largest single-phase model, rated 4 kW with 5,200 W of panel capacity and 20 A of AC output, which is about the practical ceiling before a utility asks for a three-phase connection instead. Apparent power is 4,400 VA and peak efficiency 97.5%. It shares the 6.35 kg case with the 1 kW unit, so the install is no heavier than the smallest one here.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 4 kW · Max PV input power: 5,200 W · Max AC output current: 20 A · Max apparent power: 4,400 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-4K-G04P1-EU-AM1\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 10 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e70-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/230 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e80-550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e1\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003eL\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99, VDE-AR-N 4105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Operating Current (A)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e6.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to +65℃,\u0026gt;45℃ derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"1 kW","offer_id":47869736943721,"sku":"SUN-1K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"1.5 kW","offer_id":47869736976489,"sku":"SUN-1.5K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"2 kW","offer_id":47869737009257,"sku":"SUN-2K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"2.2 kW","offer_id":47869737042025,"sku":"SUN-2.2K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"2.5 kW","offer_id":47869737074793,"sku":"SUN-2.5K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"2.7 kW","offer_id":47869737107561,"sku":"SUN-2.7K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"3 kW","offer_id":47869737140329,"sku":"SUN-3K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"3.3 kW","offer_id":47869737173097,"sku":"SUN-3.3K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"3.6 kW","offer_id":47869737205865,"sku":"SUN-3.6K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true},{"title":"4 kW","offer_id":47869737238633,"sku":"SUN-4K-G04P1-EU-AM1","price":1657.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-1-4K-G04P1.png?v=1785851346"},{"product_id":"deye-sun-g02p1-eu-am2","title":"Deye 7–10.5 kW Single-Phase Solar Inverter","description":"\u003cp\u003eThis is Deye's single-phase solar inverter for houses and small businesses that have outgrown a 5 kW unit. Six ratings sit under one listing, from 7 kW up to 10.5 kW, and every one of them converts at up to 97.7% with two independent panel inputs. The smaller three share a 12.1 kg body; the 9 kW and above move to a taller 14.8 kg case with a front screen and Wi-Fi on board.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e97.7% peak conversion, 97.2% on the European weighted average, on all six ratings\u003c\/li\u003e\n\u003cli\u003eTwo panel inputs tracking 70 V to 500 V, waking at 80 V so it starts early in the morning\u003c\/li\u003e\n\u003cli\u003eSealed well enough to sit on an outside wall (IP65), fanless, and under 35 dB\u003c\/li\u003e\n\u003cli\u003eRated from -25 to +60 C and up to 3000 m altitude, with 5 years of warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e7 kW single-phase solar inverter for a rooftop array up to 10.5 kW\u003c\/h3\u003e\u003cp\u003eThe entry point in this range, and the size most 6 kW to 8 kW rooftops land on. It takes up to 10.5 kW of panels across its two inputs and pushes out 35 A at full tilt, which is 7.7 kVA of apparent power. At 12.1 kg it is light enough for one person to lift onto a bracket. Monitoring runs over RS485 or RS232, with Wi-Fi, Bluetooth, 4G or LAN as an optional stick.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 10.5 kW · Max AC output current: 35 A · Apparent power: 7.7 kVA · Weight: 12.1 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7K-G02P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7.5 kW single-phase string inverter, 11.3 kW of panels, 12.1 kg\u003c\/h3\u003e\u003cp\u003eA half step above the 7 kW, worth taking when the array lands near 11 kW. Panel input tops out at 11.3 kW and the AC side gives 37.5 A, or 8.25 kVA. Cabinet, weight and cooling are identical to the 7 kW and 8 kW: the same 12.1 kg fanless case and the same pair of 18 A and 26 A panel inputs. Pick it only if your string layout genuinely sits between the two.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 11.3 kW · Max AC output current: 37.5 A · Apparent power: 8.25 kVA · Weight: 12.1 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7.5K-G02P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW single-phase solar inverter, 12 kW panel input, 40 A output\u003c\/h3\u003e\u003cp\u003eThe top of the lighter chassis. It accepts 12 kW of panels and its AC output reaches 40 A at 8.8 kVA, which suits a well-loaded roof on one phase. The body is the same 12.1 kg unit as the 7 kW and 7.5 kW, so mounting and clearance planning do not change. If the design calls for more than 12 kW of modules, move up to the 9 kW and its taller case.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 12 kW · Max AC output current: 40 A · Apparent power: 8.8 kVA · Weight: 12.1 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-G02P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e9 kW single-phase inverter with an LCD screen and 13.5 kW PV input\u003c\/h3\u003e\u003cp\u003eFirst model in the taller 14.8 kg case, and the first with an LCD1602 screen on the front, so an installer can read a fault without a phone. Both panel inputs are rated 26 A here rather than 18 A and 26 A, which suits two strings of equal length. It handles 13.5 kW of panels and 45 A of output, and Wi-Fi and LAN are part of the standard communication set instead of an add-on.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 13.5 kW · Max AC output current: 45 A · Apparent power: 9.9 kVA · Weight: 14.8 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-9K-G02P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e10 kW single-phase solar inverter for a 15 kW array, Wi-Fi built in\u003c\/h3\u003e\u003cp\u003eThe workhorse of the larger three. Panel input stretches to 15 kW and output reaches 50 A, or 11 kVA of apparent power, which covers a large villa or a small workshop running on one phase. Body, screen and twin 26 A inputs match the 9 kW and 10.5 kW, at 14.8 kg. Choose it over the 9 kW when the roof has space for more than 13.5 kW of modules.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 15 kW · Max AC output current: 50 A · Apparent power: 11 kVA · Weight: 14.8 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10K-G02P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e10.5 kW single-phase solar inverter, the largest in this range\u003c\/h3\u003e\u003cp\u003eThe largest single-phase unit in this family. It takes 15.8 kW of panels and delivers 52.5 A, or 11.55 kVA, which is a lot of current to carry on one phase and worth checking against your incoming supply. Everything mechanical matches the 9 kW and 10 kW: 14.8 kg, natural cooling, no fan to service. Past this point the sensible move is a three-phase inverter rather than a bigger single-phase one.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 15.8 kW · Max AC output current: 52.5 A · Apparent power: 11.55 kVA · Weight: 14.8 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10.5K-G02P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 6 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFCI Protection\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e70-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e80-550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD1602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to +60℃, \u0026gt;45℃ Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"7 kW","offer_id":47869737271401,"sku":"SUN-7K-G02P1-EU-AM2","price":2800.0,"currency_code":"AED","in_stock":true},{"title":"7.5 kW","offer_id":47869737304169,"sku":"SUN-7.5K-G02P1-EU-AM2","price":2800.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869737336937,"sku":"SUN-8K-G02P1-EU-AM2","price":2800.0,"currency_code":"AED","in_stock":true},{"title":"9 kW","offer_id":47869737369705,"sku":"SUN-9K-G02P1-EU-AM2","price":3675.0,"currency_code":"AED","in_stock":true},{"title":"10 kW","offer_id":47869737402473,"sku":"SUN-10K-G02P1-EU-AM2","price":3675.0,"currency_code":"AED","in_stock":true},{"title":"10.5 kW","offer_id":47869737435241,"sku":"SUN-10.5K-G02P1-EU-AM2","price":3675.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-9-10.5K-G02P1.png?v=1785851349"},{"product_id":"deye-sun-g03-p3","title":"Deye 70–110 kW Three-Phase Solar Inverter","description":"\u003cp\u003eThis is Deye's heavy end of the three-phase solar inverter range, the box you put on a factory roof, a cold store or a small solar farm feeding a 380\/400 V supply. Six ratings share one cabinet, so the choice comes down to how many panels you are connecting and how much current the site can take. Every unit runs on the grid alone, with no battery involved.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOne cabinet across all six ratings: 824 x 516 x 312.7 mm and 81 kg, so the mounting frame and the lifting plan never change\u003c\/li\u003e\n\u003cli\u003eSealed to IP65 and rated from -25C to 60C, which means it can hang on an outside wall in Gulf or Levant heat\u003c\/li\u003e\n\u003cli\u003eApproved for sites up to 4,000 m above sea level, covering highland projects in Africa and the Levant\u003c\/li\u003e\n\u003cli\u003eCurrent distortion stays under 3% THD, with anti-islanding, residual current detection and thermal protection built in\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e70 kW three-phase inverter for a factory roof of about 105 kW\u003c\/h3\u003e\u003cp\u003eThe entry point of the range. It accepts up to 105 kW of panels across four independent trackers, so a roof split over two or three orientations still gets tracked properly. Output tops out at 116.7 A per phase, with 106.1 A at the rated point, and the strings can run as high as 1,100 V. Its full-load tracking window is 570 to 850 V, the roomiest of the four-tracker units.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 70 kW · Max PV input: 105 kW · MPPT trackers: 4 · Max AC output current: 116.7 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-70K-G03\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e75 kW string inverter, 112.5 kW of panels on four trackers\u003c\/h3\u003e\u003cp\u003eA half step up from the 70 kW for sites where the roof takes a few more strings. It handles 112.5 kW of panels and 82.5 kVA of apparent power, giving 125 A maximum per phase against 113.6 A rated. Deye lists its rated PV input voltage at 720 V and its full-load tracking window at 610 to 850 V, so it prefers longer strings than the 70 kW does.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 75 kW · Max PV input: 112.5 kW · Apparent power: 82.5 kVA · Max AC output current: 125 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-75K-G03\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e80 kW three-phase inverter for 120 kW of panels, 133.3 A out\u003c\/h3\u003e\u003cp\u003eThe largest of the four-tracker units. It takes 120 kW of panels, rated at 88 kVA, and pushes up to 133.3 A per phase with 121.2 A at the rated point. Its full-load tracking window starts at 650 V, the highest in the range, so strings need to be long enough to sit above that before it delivers full output. Cabling and breakers should be sized for the 133.3 A figure.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 80 kW · Max PV input: 120 kW · Apparent power: 88 kVA · Full-load MPPT window: 650-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-80K-G03\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e90 kW solar inverter with six MPPT trackers and 135 kW PV input\u003c\/h3\u003e\u003cp\u003eThis is where the range switches to six trackers, so a complicated roof with six different string groups can go on one machine. It accepts 135 kW of panels and 99 kVA, delivering up to 150 A per phase. The six-tracker units also drop the maximum string voltage to 1,000 V and narrow the tracking window to 200 to 850 V, which changes how strings are laid out compared with the 70 to 80 kW units.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 90 kW · Max PV input: 135 kW · MPPT trackers: 6 · Max PV input voltage: 1,000 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-90K-G03\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e100 kW three-phase inverter, 150 kW of panels on six trackers\u003c\/h3\u003e\u003cp\u003eA 100 kW machine sharing the six-tracker platform with the 90 and 110 kW. It carries the highest panel ceiling in the range at 150 kW, tracks between 200 and 850 V and accepts strings up to 1,000 V. Worth knowing before you choose: Deye's table gives the 100 kW and the 110 kW the same 150 kW input ceiling and the same output current column, so the honest difference between them is the 100 kW rated output itself.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 100 kW · Max PV input: 150 kW · MPPT trackers: 6 · MPPT window: 200-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-100K-G03\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e110 kW inverter, the largest rating in Deye's G03 string range\u003c\/h3\u003e\u003cp\u003eThe top of the range at 110 kW of rated AC output, for the largest roofs and ground mounts on a 380\/400 V connection. It shares the six-tracker cabinet with the 100 kW model, along with the 150 kW panel ceiling, the 200 to 850 V tracking window and the 1,000 V string limit; the datasheet lists no separate current figures for it. Pick this one when the connection agreement allows the extra 10 kW of export.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 110 kW · Max PV input: 150 kW · MPPT trackers: 6 · Max PV input voltage: 1,000 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-110K-G03\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 6 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Full Load Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e550-850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e6\/4+4+4+4+4+4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eUNEIEC61727,217002,IECOVE-Richtlinie62116,CEI0-21,R25,CEIG99,0-16,VDE-AR-NEN50549,4105,NRSVDE-AR-N097,RD140,4110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC),OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eDC Injection Current: \u0026lt;0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"70 kW","offer_id":47869737468009,"sku":"DEYE-SUN-70K-G03","price":27500.0,"currency_code":"AED","in_stock":true},{"title":"75 kW","offer_id":47869737500777,"sku":"DEYE-SUN-75K-G03","price":27500.0,"currency_code":"AED","in_stock":true},{"title":"80 kW","offer_id":47869737533545,"sku":"DEYE-SUN-80K-G03","price":27500.0,"currency_code":"AED","in_stock":true},{"title":"90 kW","offer_id":47869737566313,"sku":"DEYE-SUN-90K-G03","price":27500.0,"currency_code":"AED","in_stock":true},{"title":"100 kW","offer_id":47869737599081,"sku":"DEYE-SUN-100K-G03","price":27500.0,"currency_code":"AED","in_stock":true},{"title":"110 kW","offer_id":47869737631849,"sku":"DEYE-SUN-110K-G03","price":27500.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-70-110K-G03.png?v=1785851350"},{"product_id":"deye-sun-g05-lv-p3","title":"Deye 10–15 kW Three-Phase Low-Voltage Solar Inverter","description":"\u003cp\u003eThis is Deye's three-phase solar inverter for a building already wired with a 220V or 230V three-phase supply, sold here in 10, 12 and 15 kW ratings. All three send everything the panels make straight into the building and the grid, with no battery involved, at a weighted European efficiency of 98%. The cabinet is identical across the range, so sizing up later changes nothing about the bracket or the cable run.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConnects to a 127\/220V or 133\/230V three-phase supply on 3L\/N\/PE, at 50 or 60 Hz\u003c\/li\u003e\n\u003cli\u003eTwo panel inputs, each accepting up to 26 A, with an 800 V ceiling and a 250 V start-up\u003c\/li\u003e\n\u003cli\u003e98.6% peak efficiency, 98% European weighted, and current distortion held under 3%\u003c\/li\u003e\n\u003cli\u003eSealed to IP65 and cleared to 4,000 m altitude, so an outside wall in a hot yard is fine (up to 60C)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e10 kW three-phase solar inverter for a villa or small shop rooftop\u003c\/h3\u003e\u003cp\u003eThe 10 kW takes up to 13 kW of panels, which leaves room for the usual oversizing, and pushes 26.3 A per phase into the building. Its full load window opens at 250 V, the lowest of the three, so short strings and dull winter mornings still hold rated output. Its input and output apparent power limit is 11 kVA. Choose it when the three-phase daytime load sits near 10 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 13 kW · Rated AC output current: 26.3 A · Full-load MPPT window: 250-700 V · Max input\/output apparent power: 11 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10K-G05-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e12 kW three-phase string inverter for a workshop or small factory\u003c\/h3\u003e\u003cp\u003eThe 12 kW sits in the middle of the range: 15.6 kW of panels, 31.5 A per phase and 13.2 kVA of apparent power. Its full load window starts at 300 V, so strings need to be a little longer here than on the 10 kW before the inverter will hold full output. It is the usual pick for a workshop or a pump shed whose daytime draw runs between 10 and 13 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 15.6 kW · Rated AC output current: 31.5 A · Full-load MPPT window: 300-700 V · Max input\/output apparent power: 13.2 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-12K-G05-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e15 kW three-phase solar inverter for a small commercial rooftop\u003c\/h3\u003e\u003cp\u003eThe 15 kW is the top of this range and takes 19.5 kW of panels, 6.5 kW more than the 10 kW unit, at 39.4 A per phase. Plan longer strings for it: full output needs at least 375 V from the array. Active and apparent power are both 15, so there is no reserve above the rating, worth knowing if motors dominate the load. Cabinet and weight match the smaller two.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 19.5 kW · Rated AC output current: 39.4 A · Full-load MPPT window: 375-700 V · Max input\/output apparent power: 15 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-15K-G05-LV\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 3 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFCI Protection\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e2\/2+2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232 \/WiFi\/LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNBR 16149, NBR 16150, EN 50549, RD 140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e362 x 527 x 220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"10 kW","offer_id":47869737664617,"sku":"DEYE-SUN-10K-G05-LV","price":5250.0,"currency_code":"AED","in_stock":true},{"title":"12 kW","offer_id":47869737697385,"sku":"DEYE-SUN-12K-G05-LV","price":5250.0,"currency_code":"AED","in_stock":true},{"title":"15 kW","offer_id":47869737730153,"sku":"DEYE-SUN-15K-G05-LV","price":5250.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-10-15K-G05-LV.png?v=1785851352"},{"product_id":"deye-sun-g06p3-eu-am2-p1","title":"Deye 3–15 kW Three-Phase Solar Inverter (SUN-G06P3-EU-AM2-P1)","description":"\u003cp\u003eThe SUN-G06P3-EU-AM2-P1 is Deye's three-phase solar inverter for homes and small businesses that already sit on a 380 V or 400 V supply. It is sold in ten ratings, 3 kW through 15 kW, and every one of them uses the same 11 kg wall box with two MPPT trackers and a 1,100 V panel input. Pick the rating that matches the array going on the roof; the rest of the machine does not change.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo MPPT trackers with a 120 V to 1,000 V tracking window, and panel strings allowed up to 1,100 V\u003c\/li\u003e\n\u003cli\u003eSealed for an outside wall (IP65) and rated from -25 C to 60 C, up to 4,000 m altitude\u003c\/li\u003e\n\u003cli\u003eUnder 45 dB of running noise and 11 kg on the bracket, so one person can hang it\u003c\/li\u003e\n\u003cli\u003eFeeds a 220\/380 V or 230\/400 V three-phase supply at 50 or 60 Hz, with grid, earth-fault and anti-islanding monitoring on board\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3 kW three-phase solar inverter for a small rooftop of about 4.5 kW\u003c\/h3\u003e\u003cp\u003eThe smallest of the ten, sized for a house or a shop with roughly 4.5 kW of panels, which is the most DC power it will take. It puts out 3,000 W of real power, 3.3 kVA at the ceiling, and 4.6 A per phase in normal running. Peak conversion is 98.1%, or 97.5% on the European weighting. There is no fan in this one, so nothing on it needs cleaning or replacing.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 4.5 kW · Max apparent power: 3.3 kVA · Rated output current: 4.6 A per phase · Max efficiency: 98.1%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e4 kW three-phase solar inverter that takes up to 6 kW of solar panels\u003c\/h3\u003e\u003cp\u003eOne step up from the 3 kW and physically the same box. It accepts 6 kW of panels, half again more DC than its AC rating, which is what you want when the roof faces east and west rather than south. Normal running current is 6.1 A per phase with 6.7 A available, and apparent power tops out at 4.4 kVA. Efficiency is unchanged at 98.1% peak, 97.5% European.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 6 kW · Max apparent power: 4.4 kVA · Rated output current: 6.1 A per phase · Max AC output current: 6.7 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-4K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5 kW three-phase solar inverter, 7.5 kW of panels for a family home\u003c\/h3\u003e\u003cp\u003eThe usual choice for a family house on a three-phase meter. It takes 7.5 kW of panels against a 5,000 W output, so the array can be oversized without losing much at midday, and it holds 7.6 A per phase in normal running with 8.4 A in reserve. Efficiency moves up a notch here, to 98.2% at peak and 97.6% European. Cooling is still passive, with no fan to service.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 7.5 kW · Max apparent power: 5.5 kVA · Rated output current: 7.6 A per phase · Max efficiency: 98.2%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW three-phase solar inverter for a 9 kW roof, 10 A per phase\u003c\/h3\u003e\u003cp\u003eSame case and the same 98.2% peak efficiency as the 5 kW, with more headroom on both sides: 9 kW of panels on the DC side and 6.6 kVA on the AC side. Normal running current is 9.1 A per phase and the ceiling is 10 A, which is the figure that decides your cable and breaker. European efficiency is 97.6%. It is still cooled by air alone.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 9 kW · Max apparent power: 6.6 kVA · Rated output current: 9.1 A per phase · Max AC output current: 10 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7 kW three-phase solar inverter, 10.5 kW of panels for a small shop\u003c\/h3\u003e\u003cp\u003eIt is rated at 7,000 W with 7.7 kVA of apparent power and room for 10.5 kW of panels, which suits a shop or a workshop that runs through the day. Two numbers are missing here on purpose. The datasheet prints output current for this model in a cell shared with its neighbours, and our records disagree on whether peak efficiency is 98.2% or 98.3%. We would rather quote neither than quote the wrong one.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 7,000 W · Max PV input: 10.5 kW · Max apparent power: 7.7 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW three-phase solar inverter, 12 kW of panels at 98.3% efficiency\u003c\/h3\u003e\u003cp\u003eEfficiency is 98.3% at peak and 97.8% on the European weighting, matching the 7 kW and topping the smaller ratings. It swallows 12 kW of panels, a full half again over its 8,000 W output, and delivers 8.8 kVA. The case, the weight and the two trackers match the 3 kW exactly, so wall space and mounting do not change if you upsize during design.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 12 kW · Max apparent power: 8.8 kVA · Max efficiency: 98.3% · European efficiency: 97.8%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e9 kW three-phase solar inverter for 13.5 kW of panels, 15 A ceiling\u003c\/h3\u003e\u003cp\u003eNine thousand watts out, 13.5 kW of panels in, 9.9 kVA of apparent power and a 15 A ceiling per phase. It sits between the 8 kW and the 10 kW on the same 98.3% peak and 97.8% European efficiency, and it is the largest rating in this range that still runs without a fan. Choose it when the array lands slightly over what the 8 kW will accept.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 13.5 kW · Max apparent power: 9.9 kVA · Max AC output current: 15 A · Cooling: Passive, no fan\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-9K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e10 kW three-phase solar inverter for a 15 kW commercial rooftop\u003c\/h3\u003e\u003cp\u003eTen kilowatts is the common size for a villa with heavy air conditioning or a small commercial roof. It accepts 15 kW of panels, gives 11 kVA of apparent power and 16.7 A per phase, and it holds full output across a 350 V to 650 V string window, so string design matters more here than on the smaller units. Peak efficiency stays at 98.3%.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 15 kW · Max apparent power: 11 kVA · Max AC output current: 16.7 A · Full-load MPPT window: 350-650 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e12 kW three-phase solar inverter, 18 kW of panels for a workshop\u003c\/h3\u003e\u003cp\u003eTwelve thousand watts of output, 13.2 kVA apparent and 20 A per phase, fed by as much as 18 kW of panels. Like the 10 kW it holds full output across a 350 V to 650 V string window, and it carries the same 98.3% peak and 97.8% European efficiency. This is usually the point where an installer splits the array into two separate string groups, one per tracker.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 12,000 W · Max PV input: 18 kW · Max apparent power: 13.2 kVA · Max AC output current: 20 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-12K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e15 kW three-phase solar inverter, 22.5 kW of panels at 98.5% peak\u003c\/h3\u003e\u003cp\u003eThe top of the range, and one of three ratings here with intelligent air cooling rather than passive cooling, which is how it holds 15,000 W in Gulf heat. It also carries the best conversion figures in the family, 98.5% at peak and 98% European, and it takes 22.5 kW of panels against 16.5 kVA on the AC side. The 25 A per phase ceiling decides your cable size.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax PV input: 22.5 kW · Max apparent power: 16.5 kVA · Max AC output current: 25 A · Max efficiency: 98.5%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-15K-G06P3-EU-AM2-P1\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 10 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e120-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e283 x 463 x 178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"3 kW","offer_id":47869737762921,"sku":"SUN-3K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"4 kW","offer_id":47869737795689,"sku":"SUN-4K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"5 kW","offer_id":47869737828457,"sku":"SUN-5K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869737861225,"sku":"SUN-6K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"7 kW","offer_id":47869737893993,"sku":"SUN-7K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869737926761,"sku":"SUN-8K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"9 kW","offer_id":47869737959529,"sku":"SUN-9K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"10 kW","offer_id":47869737992297,"sku":"SUN-10K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"12 kW","offer_id":47869738025065,"sku":"SUN-12K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true},{"title":"15 kW","offer_id":47869738057833,"sku":"SUN-15K-G06P3-EU-AM2-P1","price":2102.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-3-15K-G06P3-P1.png?v=1785851355"},{"product_id":"deye-sun-g06p3-eu-bm2","title":"Deye 3–15 kW Three-Phase Solar Inverter (SUN-G06P3-EU-BM2)","description":"\u003cp\u003eThe G06P3 is Deye's three-phase solar inverter for a building that already has a 400 V supply: a villa, a shop, a small workshop. Ten ratings run from 3 kW to 15 kW inside the same slim wall box with two MPPT trackers, so the same installation method covers a starter array or a full commercial roof. Pick the rating that matches the panel count you can actually fit.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo MPPT trackers with a 120 V to 1000 V window, so panels can face two different directions\u003c\/li\u003e\n\u003cli\u003eIP65 case with no fan, rated under 45 dB, quiet enough for the wall outside a bedroom\u003c\/li\u003e\n\u003cli\u003eWorks from -25 C to 60 C and up to 4,000 m, with Type II surge protection on the DC and AC sides\u003c\/li\u003e\n\u003cli\u003eAccepts 1100 V of panel voltage and reports over WiFi, 4G, LAN or Bluetooth (optional dongle)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3 kW three-phase solar inverter for a starter 4.5 kW rooftop array\u003c\/h3\u003e\u003cp\u003eThe entry point of the range, matched to roughly 4,500 W of panels, which is where most small three-phase homes begin. Output is 3,000 W, or 3,300 VA at peak, and the inverter draws only 4.6 A per phase in normal running, so it rarely forces a change to the incoming board. Conversion tops out at 98.1%, and at 11.5 kg one person can hang it on the bracket.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 4,500 W · Max AC output current: 5 A · Max apparent power: 3,300 VA · Peak efficiency: 98.1%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e4 kW three-phase solar inverter for a 6 kW array on a small villa\u003c\/h3\u003e\u003cp\u003eOne step up from the 3 kW, and the difference sits entirely on the panel side: 6,000 W of modules instead of 4,500 W. Rated current is 6.1 A per phase with 6.7 A available at the ceiling, and apparent power reaches 4,400 VA. Peak efficiency stays at 98.1%. Choose this one when the roof has room for a few more panels than the 3 kW will take.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 6,000 W · Max AC output current: 6.7 A · Max apparent power: 4,400 VA · Peak efficiency: 98.1%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-4K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5 kW three-phase inverter, 7.5 kW of panels for a family home roof\u003c\/h3\u003e\u003cp\u003eThe common size for a four-bedroom house on a three-phase supply. It carries 7,500 W of panels, delivers 5,000 W continuously and 5,500 VA at peak, and moves 7.6 A per phase. Efficiency steps up to 98.2% peak with 97.6% on the European weighted scale, so slightly more of a cloudy morning reaches the meter than on the 3 kW and 4 kW models.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 7,500 W · Max AC output current: 8.4 A · Max apparent power: 5,500 VA · European efficiency: 97.6%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW three-phase solar inverter for 9 kW of panels on a larger house\u003c\/h3\u003e\u003cp\u003eSame 98.2% peak efficiency as the 5 kW, but with 9,000 W of panel capacity and 6,600 VA of apparent power behind it. Rated current is 9.1 A per phase, which still lands inside a normal three-phase domestic circuit. This is the size to pick when the array has grown past 8 kW but the loads are still household ones: air conditioning, a pool pump, an oven.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 9,000 W · Max AC output current: 10 A · Max apparent power: 6,600 VA · Peak efficiency: 98.2%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7 kW three-phase solar inverter for a 10.5 kW small business roof\u003c\/h3\u003e\u003cp\u003eAbove 6 kW the range changes gear. The 7 kW holds full output across a 480 V to 850 V string window and lifts peak efficiency to 98.3%, with 97.8% on the European scale. It takes 10,500 W of panels and can push 12.8 A per phase, or 7,700 VA. It suits a workshop or a retail unit where the daytime load is steady rather than peaky.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 10,500 W · Max AC output current: 12.8 A · Full-load MPPT window: 480 to 850 V · Peak efficiency: 98.3%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW three-phase solar inverter for a 12 kW array on a shop or office\u003c\/h3\u003e\u003cp\u003eIt shares the 12.8 A per phase output ceiling with the 7 kW, so the AC cabling is usually identical, but it accepts 12,000 W of panels rather than 10,500 W and delivers 8,800 VA. Peak efficiency is 98.3%. Worth the step up when the roof is already full and the extra panels would otherwise be clipped in the middle of a summer day.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 12,000 W · Max AC output current: 12.8 A · Max apparent power: 8,800 VA · European efficiency: 97.8%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e9 kW three-phase solar inverter for a 13.5 kW commercial rooftop\u003c\/h3\u003e\u003cp\u003eThe 9 kW takes 13,500 W of panels and raises the output ceiling to 15 A per phase and 9,900 VA, a real step past the 7 kW and 8 kW which both stop at 12.8 A. Efficiency stays at the 98.3% peak and 97.8% European figure of the mid range. It still weighs 11.5 kg, the same as every model below it, so the mounting job does not change.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 13,500 W · Max AC output current: 15 A · Max apparent power: 9,900 VA · Weight: 11.5 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-9K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e10 kW three-phase solar inverter for a 15 kW array, 12 kg cabinet\u003c\/h3\u003e\u003cp\u003eThis is where the hardware changes: the cabinet gains half a kilo, to 12 kg. The machine carries 15,000 W of panels, 11,000 VA of apparent power and 16.7 A per phase, while peak efficiency holds at 98.3%. Pick it when the array is planned at or just under 15 kW and the main breaker has room for the extra current.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 15,000 W · Max AC output current: 16.7 A · Max apparent power: 11,000 VA · Weight: 12 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e12 kW three-phase solar inverter for an 18 kW commercial panel array\u003c\/h3\u003e\u003cp\u003eThe 12 kW accepts 18,000 W of panels and delivers 13,200 VA, with 20 A per phase at the ceiling. Peak efficiency is 98.3%. It uses the same 12 kg cabinet as the 10 kW, so a site that outgrows 10 kW can normally take the larger unit on the same bracket and the same cable route. A usual choice on warehouse and clinic roofs.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 18,000 W · Max AC output current: 20 A · Max apparent power: 13,200 VA · Weight: 12 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-12K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e15 kW three-phase solar inverter, the largest G06P3 at 98.5% peak\u003c\/h3\u003e\u003cp\u003eThe top of the range and the most efficient of the ten: 98.5% peak and 98% on the European scale, against 98.3% for the models below. It takes 22,500 W of panels, 16,500 VA of apparent power and 25 A per phase. The cabinet is 188 mm deep, 10 mm more than the 3 kW, and weighs 12 kg. It is sized for a commercial roof running on one inverter rather than two.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 22,500 W · Max AC output current: 25 A · Peak efficiency: 98.5% · Cabinet depth: 188 mm\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-15K-G06P3-EU-BM2\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 10 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IECOVE-Richtlinie62116,CEI0-21,R25,ENG98,50549,G99,NRSVDE-AR-N097,RD4105140,UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e120-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e19.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"3 kW","offer_id":47869738090601,"sku":"SUN-3K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"4 kW","offer_id":47869738123369,"sku":"SUN-4K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"5 kW","offer_id":47869738156137,"sku":"SUN-5K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869738188905,"sku":"SUN-6K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"7 kW","offer_id":47869738221673,"sku":"SUN-7K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869738254441,"sku":"SUN-8K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"9 kW","offer_id":47869738287209,"sku":"SUN-9K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"10 kW","offer_id":47869738319977,"sku":"SUN-10K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"12 kW","offer_id":47869738352745,"sku":"SUN-12K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true},{"title":"15 kW","offer_id":47869738385513,"sku":"SUN-15K-G06P3-EU-BM2","price":2628.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-3-15K-G06P3.png?v=1785851358"},{"product_id":"deye-sun-sg01hp3-eu-am2","title":"Deye 5–25 kW Three-Phase High-Voltage Hybrid Solar Inverter","description":"\u003cp\u003eThis Deye three-phase hybrid inverter runs your solar panels, your batteries and your grid connection from one wall-mounted box, in eight ratings from 5 kW up to 25 kW. All eight take a high-voltage lithium stack anywhere between 160 V and 700 V, and all eight peak at 97.6% conversion efficiency. Pick the rating by how much panel you plan to fit and how much load the house or workshop draws at once.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePeak conversion efficiency of 97.6%, with a 97% European weighted average\u003c\/li\u003e\n\u003cli\u003eTakes a high-voltage lithium battery stack from 160 V to 700 V on a single battery input\u003c\/li\u003e\n\u003cli\u003eSealed to IP65 and rated from -40 C to 60 C, so it can live on an outside wall\u003c\/li\u003e\n\u003cli\u003eUp to 10 units parallel on one site, and panel strings up to 1,000 V connect directly\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e5 kW three-phase hybrid inverter for a small villa, fanless and quiet\u003c\/h3\u003e\u003cp\u003eThe smallest of the eight, rated 5,000 W continuous and 5,500 VA apparent, giving 8.4 A per phase. It cools by convection alone, with no fan, so it stays silent on a hallway or garage wall. You can hang up to 10,000 W of panel on it, and it charges or discharges the battery at up to 30 A. Grid passthrough is 40 A.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel array: 10,000 W · Battery charge and discharge: 30 A · Max AC output current: 8.4 A · Cooling: Convection, no fan\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-SG01HP3-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW three-phase hybrid inverter for a family home with a bigger roof\u003c\/h3\u003e\u003cp\u003eSame silent fanless cabinet as the 5 kW, stepped up to 6,000 W continuous and 6,600 VA, which is 10 A per phase. It carries up to 12,000 W of panel, 2,000 W more than the 5 kW, while battery current stays at 30 A each way. A sensible pick when the roof is larger than the load, since surplus can be exported or banked.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel array: 12,000 W · Max apparent power: 6,600 VA · Max AC output current: 10 A · Cooling: Convection, no fan\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-SG01HP3-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW three-phase hybrid inverter for a home with air conditioning load\u003c\/h3\u003e\u003cp\u003eThis is where the range picks up a fan: the 8 kW switches to managed air cooling, which lets it hold 8,000 W continuous and 8,800 VA in the same size case. Battery current rises to 37 A charging and discharging, a useful jump over the 30 A of the two smaller units. Panel capacity is 16,000 W, and the full-load tracking window starts at 260 V.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel array: 16,000 W · Battery charge and discharge: 37 A · Max AC output current: 13.4 A · Full-load tracking window: 260 to 850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-SG01HP3-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e10 kW three-phase hybrid inverter for a large villa or a small workshop\u003c\/h3\u003e\u003cp\u003eTen thousand watts continuous, 11,000 VA apparent, and 16.7 A on each of the three phases. That is enough to carry several air conditioners and a pool pump at the same time without the grid helping. The panel budget is 20,000 W, double the 5 kW model, and the full-load tracking window narrows to 325 to 850 V, so strings need to be long enough to sit inside it.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel array: 20,000 W · Max apparent power: 11,000 VA · Max AC output current: 16.7 A · Full-load tracking window: 325 to 850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10K-SG01HP3-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e12 kW three-phase hybrid inverter with 80 A grid passthrough for shops\u003c\/h3\u003e\u003cp\u003eThe 12 kW is the first in the range to double its grid passthrough to 80 A, which matters if you have a big incoming supply and want the inverter in line with all of it rather than a sub-board. It handles 12,000 W continuous, 13,200 VA, and 20 A per phase, with room for 24,000 W of panel. One tracker also steps up to 26 A of string current.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel array: 24,000 W · Grid passthrough: 80 A · Max AC output current: 20 A · String input current: 26 A + 20 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-12K-SG01HP3-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e15 kW three-phase hybrid inverter for a farm, clinic or small factory\u003c\/h3\u003e\u003cp\u003eFifteen thousand watts continuous and 16,500 VA, delivering 25 A on each phase, still inside the same 30.5 kg wall case as the 5 kW. Panel capacity reaches 30,000 W. The catch is the full-load tracking window, which begins at 420 V, so short strings will not push it to full output on a dull morning. Grid passthrough is 80 A.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel array: 30,000 W · Max apparent power: 16,500 VA · Max AC output current: 25 A · Full-load tracking window: 420 to 850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-15K-SG01HP3-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e20 kW three-phase hybrid inverter, the heaviest cabinet at 51.9 kg\u003c\/h3\u003e\u003cp\u003eThe 20 kW moves to a bigger case: 456 by 750 by 268.5 mm and 51.9 kg, so plan a two-person lift. It gives 20,000 W continuous, 22,000 VA and 33.4 A per phase, and both trackers now carry 26 A, for a total panel budget of 40,000 W. Battery charge and discharge stays at 37 A, the same as the 8 kW through 15 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel array: 40,000 W · Max AC output current: 33.4 A · Weight: 51.9 kg · Case size: 456 x 750 x 268.5 mm\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-20K-SG01HP3-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e25 kW three-phase hybrid inverter with 50 A battery current, top model\u003c\/h3\u003e\u003cp\u003eThe top of the range is also the only one that charges and discharges the battery at 50 A rather than 37 A, so a large stack refills faster on a short sunny window. It puts out 25,000 W continuous and 27,500 VA, 41.7 A per phase, and takes 50,000 W of panel. Rated PV input voltage is 700 V here, higher than the 600 V used by every other rating, and it weighs 37.1 kg.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel array: 50,000 W · Battery charge and discharge: 50 A · Rated PV input voltage: 700 V · Weight: 37.1 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-25K-SG01HP3-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 8 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e160-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS232, RS485, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e1.5 time of rated power, 10 S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e180-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-40 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e30.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"5 kW","offer_id":47869738418281,"sku":"SUN-5K-SG01HP3-EU-AM2","price":4423.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869738451049,"sku":"SUN-6K-SG01HP3-EU-AM2","price":4423.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869738483817,"sku":"SUN-8K-SG01HP3-EU-AM2","price":4423.0,"currency_code":"AED","in_stock":true},{"title":"10 kW","offer_id":47869738516585,"sku":"SUN-10K-SG01HP3-EU-AM2","price":4423.0,"currency_code":"AED","in_stock":true},{"title":"12 kW","offer_id":47869738549353,"sku":"SUN-12K-SG01HP3-EU-AM2","price":4423.0,"currency_code":"AED","in_stock":true},{"title":"15 kW","offer_id":47869738582121,"sku":"SUN-15K-SG01HP3-EU-AM2","price":4423.0,"currency_code":"AED","in_stock":true},{"title":"20 kW","offer_id":47869738614889,"sku":"SUN-20K-SG01HP3-EU-AM2","price":4423.0,"currency_code":"AED","in_stock":true},{"title":"25 kW","offer_id":47869738647657,"sku":"SUN-25K-SG01HP3-EU-AM2","price":4423.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-5-25K-SG01HP3-EU.png?v=1785851362"},{"product_id":"deye-sun-sg04lp3-eu","title":"Deye 5–12 kW Three-Phase Low-Voltage Hybrid Solar Inverter","description":"\u003cp\u003eDeye's SG04LP3 range is a three-phase hybrid inverter for a 400V house or workshop supply, sold in five ratings from 5 kW to 12 kW. Each one runs solar, a 48V battery and the grid together, and carries the load on its own when the grid fails. Picking the rating is really picking two things: how much you can run at once, and how fast the battery refills.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRuns a 48V battery bank, lead-acid or lithium, over a 40 to 60 V window\u003c\/li\u003e\n\u003cli\u003eIP65 sealed for an outside wall, fan cooled, and no louder than 55 dB\u003c\/li\u003e\n\u003cli\u003eTwo solar inputs, 97.6% peak efficiency, and an 800 V ceiling on the array\u003c\/li\u003e\n\u003cli\u003eHandles uneven loads at up to 50% of rated power on any one phase, plus 45 A of grid passthrough\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e5 kW three-phase hybrid inverter, 48V, for a modest family home\u003c\/h3\u003e\u003cp\u003eThe smallest in the range and the one most three-bedroom homes land on. It charges the battery at up to 120 A and takes 7,500 W of panels, with 10,000 W the largest array Deye allows on it. Output peaks at 5,500 VA, 8.4 A per phase. If your evening load is lighting, a fridge, a couple of air conditioners and a water pump, this is the size that fits.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax charge and discharge current: 120 A · Max PV input power: 7,500 W · Largest permitted array: 10,000 W · Peak apparent power: 5,500 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-SG04LP3-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW three-phase hybrid inverter for a home with two air conditioners\u003c\/h3\u003e\u003cp\u003eOne step up from the 5 kW, and the step is real: 150 A of battery charging instead of 120 A, and 9,000 W of panels instead of 7,500 W. Deye allows a 12,000 W array on it. Peak output is 6,600 VA at 10 A per phase. Worth the difference if you already know the roof will grow, because the extra panel headroom is where the value sits.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax charge and discharge current: 150 A · Max PV input power: 9,000 W · Largest permitted array: 12,000 W · Peak apparent power: 6,600 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-SG04LP3-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW three-phase hybrid inverter for a large villa or small workshop\u003c\/h3\u003e\u003cp\u003eThis is the last rating in the range that still uses the narrower solar inputs, 13 A on each of the two trackers. It charges at 190 A, takes 12,000 W of panels and allows a 16,000 W array, reaching 8,800 VA and 13.4 A per phase at maximum output. A good match for a villa running several air conditioners, or a shop with a chiller and a few motors.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax charge and discharge current: 190 A · Max PV input power: 12,000 W · Largest permitted array: 16,000 W · Max AC output current: 13.4 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-SG04LP3-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e10 kW three-phase hybrid inverter for a big villa or a small business\u003c\/h3\u003e\u003cp\u003eThe 10 kW is where the hardware changes, not just the numbers. Its first solar tracker takes 26 A rather than 13 A, so wider strings can go into it, and the unit adds reverse-polarity protection on the DC side plus insulation monitoring. Charging reaches 210 A, panels 15,000 W, array 20,000 W. Deye lists this rating at 60 Hz nominal, so confirm the grid setting with your installer.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax charge and discharge current: 210 A · Max PV input power: 15,000 W · PV input current, first tracker: 26 A · Max output fault current: 33.4 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10K-SG04LP3-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e12 kW three-phase hybrid inverter, the largest in this 5 to 12 kW range\u003c\/h3\u003e\u003cp\u003eThe largest of the five and the one that leaves the most room to grow into. It charges at 240 A, takes 18,000 W of panels and allows a 24,000 W array, with 13,200 VA peak and 18.2 A per phase at the rated output. Like the 10 kW it carries the wider 26 A first tracker, and its output fault rating is 40 A. Deye lists this one at 60 Hz nominal too, so check that against your grid.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax charge and discharge current: 240 A · Max PV input power: 18,000 W · Largest permitted array: 24,000 W · Max output fault current: 40 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-12K-SG04LP3-EU\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 5 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e160-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e40-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS232, RS485, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Full Load Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e350-650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIECUNE61727,IEC217002,OVE-Richtlinie62116,CEI0-21,ENR25,G99,VDE-AR-N50549,NRS097,RD4105140,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Passthrough (A)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V,230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e2 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e422 x 658 x 254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"5 kW","offer_id":47869738680425,"sku":"DEYE-SUN-5K-SG04LP3-EU","price":5914.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869738713193,"sku":"DEYE-SUN-6K-SG04LP3-EU","price":5914.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869738745961,"sku":"DEYE-SUN-8K-SG04LP3-EU","price":7661.0,"currency_code":"AED","in_stock":true},{"title":"10 kW","offer_id":47869738778729,"sku":"DEYE-SUN-10K-SG04LP3-EU","price":5914.0,"currency_code":"AED","in_stock":true},{"title":"12 kW","offer_id":47869738811497,"sku":"DEYE-SUN-12K-SG04LP3-EU","price":5914.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-5-12K-SG04LP3-EU.png?v=1785851364"},{"product_id":"deye-sun-sg05lp1-eu-sm2-p","title":"Deye 3.6–10 kW Single-Phase Low-Voltage Hybrid Solar Inverter","description":"\u003cp\u003eThis is Deye's single-phase hybrid inverter range for homes on a 230 V supply, sold in seven sizes from 3.6 kW to 10 kW. Every unit runs solar panels, a 48 V battery bank and the grid together, and keeps the house alive when the grid drops out. The cabinet, the touchscreen and the 97.6% peak efficiency are the same across all seven; what changes is how much panel and battery current each one will take.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTakes a lead-acid or lithium battery bank anywhere from 40 to 60 V, on one battery input\u003c\/li\u003e\n\u003cli\u003e97.6% peak efficiency and 96.5% European efficiency, with two MPPT trackers and a 500 V panel limit\u003c\/li\u003e\n\u003cli\u003eSealed well enough to sit on an outside wall (IP65) and quiet at under 30 dB\u003c\/li\u003e\n\u003cli\u003eUp to 16 units wired in parallel, and it works from -40 to 60 C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3.6 kW single-phase hybrid solar inverter for a flat or a small home\u003c\/h3\u003e\u003cp\u003eThis is the entry point of the range at 3,600 W, and it suits a flat or a small home whose big loads are a fridge, lighting and one air conditioner. It takes up to 5,760 W of panel input, with 7,200 W of array allowed to be wired in, and charges the battery at up to 90 A. Grid passthrough is 35 A, so a modest incoming supply feeds the loads directly when the sun is down.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 3,600 W · Battery charge and discharge: 90 A · Max PV input: 5,760 W · Grid passthrough: 35 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3.6K-SG05LP1-EU-SM2-P\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5 kW single-phase hybrid solar inverter for a four-bedroom villa\u003c\/h3\u003e\u003cp\u003eThe 5 kW model lifts battery current to 120 A, so a 48 V bank refills noticeably faster than on the 3.6 kW unit, and the panel budget grows to 8,000 W of input. Output is 5,500 VA and 25 A on a single phase, which covers a four-bedroom home running two or three air conditioners. Grid passthrough stays at 35 A, the same as the smallest unit, so the incoming supply is the thing to check.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 5,000 W · Battery charge and discharge: 120 A · Max PV input: 8,000 W · AC output current: 25 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-SG05LP1-EU-SM2-P\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW single-phase hybrid solar inverter with 135 A battery charging\u003c\/h3\u003e\u003cp\u003eThe 6 kW unit gives 6,000 W, 6,600 VA of apparent power and 30 A of output current, enough for a villa running air conditioning through the afternoon. Battery charge and discharge reach 135 A, and grid passthrough rises to 40 A, one step above the 3.6 and 5 kW models. Panel input is 9,600 W with up to 12,000 W of array allowed, so a roof already full of panels is not wasted.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 6,000 W · Battery charge and discharge: 135 A · Max PV input: 9,600 W · Grid passthrough: 40 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-SG05LP1-EU-SM2-P\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7 kW single-phase hybrid solar inverter for a large family home\u003c\/h3\u003e\u003cp\u003eThe 7 kW is where the solar side changes. Input current per tracker jumps from 18 A to 32 A and the short-circuit rating from 27 A to 48 A, so longer, higher-current strings are allowed, and full-load tracking begins at 200 V instead of 300 V. Battery charge and discharge run to 175 A, output is 7,700 VA, and the array budget is 14,000 W. It fits a large family home with a deep battery bank.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 7,000 W · Battery charge and discharge: 175 A · PV input current per tracker: 32 A · Full-load MPPT range: 200 to 425 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7K-SG05LP1-EU-SM2-P\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7.6 kW single-phase hybrid solar inverter with 50 A grid passthrough\u003c\/h3\u003e\u003cp\u003eAt 7,600 W rated output this model sits between the 7 kW and 8 kW units, and it is the smallest in the range to get the 50 A grid passthrough rather than 40 A. Battery charge and discharge run to 190 A, apparent power to 8,360 VA, and the panel budget is 12,160 W of input with 15,200 W of array. Full-load tracking works from 200 V, the same wide window as the 7 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 7,600 W · Battery charge and discharge: 190 A · Max PV input: 12,160 W · Grid passthrough: 50 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7.6K-SG05LP1-EU-SM2-P\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW single-phase hybrid solar inverter for a shop or small workshop\u003c\/h3\u003e\u003cp\u003eThe 8 kW delivers 8,800 VA and 40 A of output on one phase, which covers a shop, a small workshop or a villa with a pool pump. It shares the 190 A battery current of the 7.6 kW model but takes more panels: 12,800 W of input and 16,000 W of array. Full-load MPPT tracking starts at 250 V here rather than the 200 V of the 7 and 7.6 kW units, so string length matters.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 8,000 W · Apparent power: 8,800 VA · Max PV array: 16,000 W · Full-load MPPT range: 250 to 425 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-SG05LP1-EU-SM2-P\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e10 kW single-phase hybrid solar inverter for a large villa or shop unit\u003c\/h3\u003e\u003cp\u003eTop of the range at 10,000 W and 11,000 VA, with 50 A of output current on a single phase. Battery charge and discharge reach 210 A, the highest figure in this family, and the panel budget is 16,000 W of input with 20,000 W of array allowed, close to triple what the 3.6 kW unit takes. Grid passthrough is 50 A, matching the 8 kW model. Suits a large villa or a small commercial unit.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 10,000 W · Battery charge and discharge: 210 A · Max PV input: 16,000 W · AC output current: 50 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10K-SG05LP1-EU-SM2-P\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 7 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\/45Hz-55Hz 60Hz\/55Hz-65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLead-acid or Lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e40-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003eL+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eColorful Touch LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\/45Hz-55Hz 60Hz\/55Hz-65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/230 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e2 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e96.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e125-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-40 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"3.6 kW","offer_id":47869738844265,"sku":"SUN-3.6K-SG05LP1-EU-SM2-P","price":3280.0,"currency_code":"AED","in_stock":true},{"title":"5 kW","offer_id":47869738877033,"sku":"SUN-5K-SG05LP1-EU-SM2-P","price":3280.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869738909801,"sku":"SUN-6K-SG05LP1-EU-SM2-P","price":3280.0,"currency_code":"AED","in_stock":true},{"title":"7 kW","offer_id":47869738942569,"sku":"SUN-7K-SG05LP1-EU-SM2-P","price":3280.0,"currency_code":"AED","in_stock":true},{"title":"7.6 kW","offer_id":47869738975337,"sku":"SUN-7.6K-SG05LP1-EU-SM2-P","price":3280.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869739008105,"sku":"SUN-8K-SG05LP1-EU-SM2-P","price":3280.0,"currency_code":"AED","in_stock":true},{"title":"10 kW","offer_id":47869739040873,"sku":"SUN-10K-SG05LP1-EU-SM2-P","price":3280.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-3.6-10K-SG05LP1-SM2.png?v=1785851366"},{"product_id":"deye-sun-sg05lp3-eu-sm2","title":"Deye 3–20 kW Three-Phase Low-Voltage Hybrid Solar Inverter","description":"\u003cp\u003eThe SUN-SG05LP3-EU-SM2 is Deye's three-phase hybrid inverter for buildings wired at 380 or 400 V, in twelve sizes from a 3 kW house up to a 20 kW commercial roof. Each one runs the panels, charges a 48 V battery and keeps the loads alive when the grid drops, all from a single wall-mounted box. Sizes from 3 to 12 kW share one 35.2 kg case; 14 kW and above move to a bigger case with two battery inputs.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWorks with a 48 V bank, lead-acid or lithium, anywhere between 40 and 60 V, so an existing battery usually carries over.\u003c\/li\u003e\n\u003cli\u003eTwo MPPT trackers and an 800 V maximum PV input, which lets long roof strings come straight in without extra gear.\u003c\/li\u003e\n\u003cli\u003eThe case is sealed to IP65 and rated to 3,000 m, air cooled, and specified from -40 up to +60 C with derating above 45 C.\u003c\/li\u003e\n\u003cli\u003eTen units run in parallel, and each holds twice its rated power for 10 seconds when a pump or compressor starts.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3 kW three-phase hybrid inverter for a small home or a workshop\u003c\/h3\u003e\u003cp\u003eThis is the smallest unit in the range and suits a modest three-phase home or a workshop running lights, a fridge and one or two air conditioners. It accepts up to 6,000 W of panels, holds 3,300 VA on its output and charges a 48 V bank at up to 70 A. Rated output current is 4.6 A per phase. The case weighs 35.2 kg and takes one battery input, so a single bank is the intended setup.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 70 A · Max PV array: 6,000 W · Max apparent power: 3,300 VA · Rated output current: 4.6 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3K-SG05LP3-EU-SM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e4 kW three-phase hybrid inverter for a home with a larger solar roof\u003c\/h3\u003e\u003cp\u003eStep up from the 3 kW when the roof is bigger than the loads. This one carries 8,000 W of panels, 4,400 VA of output and charges the battery at up to 95 A against 70 A on the 3 kW. Rated output is 6.1 A per phase. It uses the same 35.2 kg wall case and the same single battery input, so the extra kilowatt costs nothing in wall space or cabling.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 95 A · Max PV array: 8,000 W · Max apparent power: 4,400 VA · Rated output current: 6.1 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-4K-SG05LP3-EU-SM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5 kW three-phase hybrid inverter, the usual size for a family villa\u003c\/h3\u003e\u003cp\u003eThe size most villas end up with. It takes 10,000 W of panels, delivers 5,500 VA and pushes up to 120 A into the battery, so a bank refills through the middle of the day instead of trickling all afternoon. Rated output is 7.6 A per phase. Panels feed two trackers with a 250 to 650 V full load window, and the unit still fits the 35.2 kg wall case used by every model below 14 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 120 A · Max PV array: 10,000 W · Max apparent power: 5,500 VA · Rated output current: 7.6 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-SG05LP3-EU-SM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW three-phase hybrid inverter for a villa with heavy air conditioning\u003c\/h3\u003e\u003cp\u003eChoose this over the 5 kW when several air conditioners run at once. Output rises to 6,600 VA and 9.1 A per phase, the array can reach 12,000 W, and charging climbs to 135 A. Everything else matches the smaller units: one battery input, 45 A of grid passthrough to the loads and the same 35.2 kg case, so an installer sizing the distribution board has nothing new to work out.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 135 A · Max PV array: 12,000 W · Max apparent power: 6,600 VA · Rated output current: 9.1 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-SG05LP3-EU-SM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW three-phase hybrid inverter for a large villa or a small shop\u003c\/h3\u003e\u003cp\u003eThe first real jump in the range. PV input rises to 12,800 W with a 16,000 W array allowed, each tracker takes 26 A instead of 20 A, and the full load window narrows to 350 to 650 V, so strings need to be a little longer than on the 6 kW. Output is 8,800 VA at 12.2 A per phase and the battery charges at 190 A. It keeps the 35.2 kg case and one battery input.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 190 A · Max PV array: 16,000 W · Max apparent power: 8,800 VA · Rated output current: 12.2 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-SG05LP3-EU-SM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e10 kW three-phase hybrid inverter for a shop, a clinic or farm pumps\u003c\/h3\u003e\u003cp\u003eA good match for a shop, a clinic or a farm with pumps. It handles a 20,000 W array, 11,000 VA of output and 15.2 A per phase, with battery charging at 210 A. This model also lists reverse polarity protection on the DC side and insulation resistance monitoring. Grid passthrough to the loads stays at 45 A, so the largest non-solar loads pass through the unit rather than round it.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 210 A · Max PV array: 20,000 W · Max apparent power: 11,000 VA · Rated output current: 15.2 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-10K-SG05LP3-EU-SM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e12 kW three-phase hybrid inverter for a busy shop or a light workshop\u003c\/h3\u003e\u003cp\u003eThe largest unit that still uses the 35.2 kg case and a single battery input, which makes it the easiest of the bigger sizes to fit where wall space is tight. The array can reach 24,000 W, output is 13,200 VA at 18.2 A per phase, and the battery charges at 240 A. Like the 10 kW it carries DC reverse polarity protection and insulation resistance monitoring.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 240 A · Max PV array: 24,000 W · Max apparent power: 13,200 VA · Rated output current: 18.2 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-12K-SG05LP3-EU-SM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e14 kW three-phase hybrid inverter with two battery inputs for business use\u003c\/h3\u003e\u003cp\u003eHere the hardware changes. The 14 kW moves to a larger 51.9 kg case with two battery inputs instead of one and 70 A of grid passthrough rather than 45 A. It takes a 28,000 W array, gives 15,400 VA at 21.3 A per phase and charges at 260 A. The tracking window also widens at the bottom to 160 V, which helps on dull mornings. Fan noise is quoted at 60 dB.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 260 A · Max PV array: 28,000 W · Max apparent power: 15,400 VA · Battery inputs: 2\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-14K-SG05LP3-EU-SM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e15 kW three-phase hybrid inverter for a small factory or a cold store\u003c\/h3\u003e\u003cp\u003eA step up inside the big case: 30,000 W of panels, 16,500 VA of output and 22.8 A per phase, with the battery charging at 280 A across its two inputs. Full load tracking starts at 330 V. It suits a small factory or a cold store where a compressor cycles all day and the roof is large enough to keep the bank topped up between cycles.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 280 A · Max PV array: 30,000 W · Max apparent power: 16,500 VA · Rated output current: 22.8 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-15K-SG05LP3-EU-SM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e16 kW three-phase hybrid inverter for a workshop with motor loads\u003c\/h3\u003e\u003cp\u003eThe middle of the large-case group. It allows a 32,000 W array, produces 17,600 VA at 24.3 A per phase and charges at 300 A. Full load tracking begins at 350 V, so strings want to be longer than on the 14 kW. With 70 A of passthrough and two battery inputs it copes with a workshop where motors start and stop through the day and the load never settles.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 300 A · Max PV array: 32,000 W · Max apparent power: 17,600 VA · Rated output current: 24.3 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-16K-SG05LP3-EU-SM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e18 kW three-phase hybrid inverter for a commercial rooftop array\u003c\/h3\u003e\u003cp\u003eThis one is aimed at a commercial roof. The array can reach 36,000 W, output is 19,800 VA at 27.3 A per phase and charging runs to 330 A. Full load tracking starts at 400 V, which means longer strings than any smaller model here. It shares the 51.9 kg case, the two battery inputs and the 70 A grid passthrough with the rest of the large group.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 330 A · Max PV array: 36,000 W · Max apparent power: 19,800 VA · Rated output current: 27.3 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-18K-SG05LP3-EU-SM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e20 kW three-phase hybrid inverter, the largest in this low-voltage range\u003c\/h3\u003e\u003cp\u003eThe top of the low-voltage three-phase range. It takes 40,000 W of panels, delivers 22,000 VA at 30.4 A per phase and charges the battery at 350 A, the highest figure here. Full load tracking begins at 440 V, so this one wants long strings and a big roof. Ten units run in parallel, which is how a 200 kW site gets built out of stock parts rather than a custom cabinet.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 350 A · Max PV array: 40,000 W · Max apparent power: 22,000 VA · Rated output current: 30.4 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-20K-SG05LP3-EU-SM2\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 12 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e160-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLead-acid or Lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e40-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097, RD4105140, UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated (solar), Isolated (battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V,230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e2 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalanced Output (%)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"3 kW","offer_id":47869739073641,"sku":"SUN-3K-SG05LP3-EU-SM2","price":6786.0,"currency_code":"AED","in_stock":true},{"title":"4 kW","offer_id":47869739106409,"sku":"SUN-4K-SG05LP3-EU-SM2","price":6786.0,"currency_code":"AED","in_stock":true},{"title":"5 kW","offer_id":47869739139177,"sku":"SUN-5K-SG05LP3-EU-SM2","price":6786.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869739171945,"sku":"SUN-6K-SG05LP3-EU-SM2","price":6786.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869739204713,"sku":"SUN-8K-SG05LP3-EU-SM2","price":6786.0,"currency_code":"AED","in_stock":true},{"title":"10 kW","offer_id":47869739237481,"sku":"SUN-10K-SG05LP3-EU-SM2","price":6786.0,"currency_code":"AED","in_stock":true},{"title":"12 kW","offer_id":47869739270249,"sku":"SUN-12K-SG05LP3-EU-SM2","price":6786.0,"currency_code":"AED","in_stock":true},{"title":"14 kW","offer_id":47869739303017,"sku":"SUN-14K-SG05LP3-EU-SM2","price":10328.0,"currency_code":"AED","in_stock":true},{"title":"15 kW","offer_id":47869739335785,"sku":"SUN-15K-SG05LP3-EU-SM2","price":10328.0,"currency_code":"AED","in_stock":true},{"title":"16 kW","offer_id":47869739368553,"sku":"SUN-16K-SG05LP3-EU-SM2","price":10328.0,"currency_code":"AED","in_stock":true},{"title":"18 kW","offer_id":47869739401321,"sku":"SUN-18K-SG05LP3-EU-SM2","price":10328.0,"currency_code":"AED","in_stock":true},{"title":"20 kW","offer_id":47869739434089,"sku":"SUN-20K-SG05LP3-EU-SM2","price":10328.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-14-20K-SG05LP3-EU.png?v=1785851369"},{"product_id":"deye-sun-g01p3-eu-am8","title":"Deye 120–136 kW Three-Phase Solar Inverter","description":"\u003cp\u003eThis is the largest three-phase solar inverter Deye builds for rooftops and ground mounts that need real capacity: five ratings from 120 kW up to 136 kW, all on the same 103 kg chassis. Eight separate tracker inputs let you run strings at different angles or on different roof faces without one shaded string pulling the rest down. Every unit is sealed to IP65 and keeps working to 60°C ambient, with output derating above 45°C.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEight MPPT tracker inputs, each taking up to 40 A, so strings on different roof faces are handled separately.\u003c\/li\u003e\n\u003cli\u003e98.8% peak efficiency and 98.2% European efficiency across the whole range.\u003c\/li\u003e\n\u003cli\u003eIP65 sealed with intelligent air cooling, rated from -25°C to 60°C and up to 4,000 m altitude.\u003c\/li\u003e\n\u003cli\u003eThe same 1006 x 516 x 325.5 mm body at 103 kg, so mounting hardware is identical whichever rating you pick.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e120 kW three-phase inverter for large commercial rooftops and sheds\u003c\/h3\u003e\u003cp\u003eThe 120 kW is the only unit here rated at 132 kVA, and its 200 A maximum output current is the lowest in the range, which usually means a smaller AC cable and a cheaper breaker. Rated output current sits at 181.9 A. It accepts up to 180 kW of panels, so a 1.5 ratio of array to inverter still fits. Pick it when the grid connection caps you near 120 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 120 kW · Max apparent power: 132 kVA · Max AC output current: 200 A · Max PV input: 180 kW\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-120K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e125 kW three-phase string inverter, a small step up on the same frame\u003c\/h3\u003e\u003cp\u003eAt 125 kW the apparent power climbs to 135 kVA and rated output current to 189.4 A, while the panel ceiling rises to 187.5 kW. That extra 7.5 kW of array headroom over the 120 kW unit is the practical reason to choose it: you fit two or three more strings without buying a second inverter. Cabling, mounting frame and enclosure stay exactly the same.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 125 kW · Max apparent power: 135 kVA · Rated output current: 189.4 A · Max PV input: 187.5 kW\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-125K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e130 kW three-phase inverter for a 195 kW array on one connection\u003c\/h3\u003e\u003cp\u003eThe 130 kW takes up to 195 kW of panels and runs a rated output current of 197 A. Its 204.6 A maximum output current and 135 kVA apparent power are shared with the 125 kW and 135 kW units, so the real gain is 7.5 kW more array than the 125 kW model on identical AC hardware. That suits a site where roof space is the limit rather than the grid connection.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 130 kW · Rated output current: 197 A · Max PV input: 195 kW · Max apparent power: 135 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-130K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e135 kW three-phase inverter that runs at its own current ceiling\u003c\/h3\u003e\u003cp\u003eAt 135 kW the rated output current and the maximum output current are the same number, 204.6 A, so the unit works at the top of its 135 kVA rating continuously instead of holding a reserve. Panel input goes to 202.5 kW. Size the AC breaker and cable for 204.6 A on this model, not for a lower rated figure, because on this one the two values are identical.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 135 kW · Rated output current: 204.6 A · Max PV input: 202.5 kW · Max apparent power: 135 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-135K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e136 kW three-phase inverter, the largest rating in the AM8 range\u003c\/h3\u003e\u003cp\u003eThe 136 kW sits at the top of the family and is the only one rated 136 kVA, with rated and maximum output current both at 206.1 A. It carries up to 204 kW of panels, the largest array allowance here. Choose it when your grid connection can take 206.1 A per phase and you want every kilowatt the chassis offers. The 135 kW model gives up 1.5 kW of array for almost the same current.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 136 kW · Max apparent power: 136 kVA · Max AC output current: 206.1 A · Max PV input: 204 kW\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-136K-G01P3-EU-AM8\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 5 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Injection (%)\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Full Load Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e550-850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e8\/4+4+4+4+4+4+4+4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Ocp (A)\u003c\/td\u003e\n\u003ctd\u003e398\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232 \/WiFi\/LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e1006 x 516 x 325.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"120 kW","offer_id":47869739466857,"sku":"SUN-120K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true},{"title":"125 kW","offer_id":47869739499625,"sku":"SUN-125K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true},{"title":"130 kW","offer_id":47869739532393,"sku":"SUN-130K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true},{"title":"135 kW","offer_id":47869739565161,"sku":"SUN-135K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true},{"title":"136 kW","offer_id":47869739597929,"sku":"SUN-136K-G01P3-EU-AM8","price":12567.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-120-136K-G01P3.png?v=1785851372"},{"product_id":"deye-sun-sg01lp1-eu","title":"Deye 7.6–16 kW Single-Phase Low-Voltage Hybrid Solar Inverter","description":"\u003cp\u003eThis single-phase hybrid inverter family runs a house on solar by day, stores what is left in a 48 V battery bank, and moves the house onto that bank when the grid drops. Five ratings sit on one platform, from 7.6 kW for a normal villa up to 16 kW for a large home or a workshop with heavy motors. The two smaller units take one battery bank, the 12 kW and above take two.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRuns on any 40-60 V bank, lead-acid or lithium, and reads a lithium BMS by itself\u003c\/li\u003e\n\u003cli\u003e97.6% peak efficiency, 96.5% European weighted\u003c\/li\u003e\n\u003cli\u003eSealed to IP65 for an outside wall, rated from -40 to 60 degrees C\u003c\/li\u003e\n\u003cli\u003eHolds double its rated power for 10 seconds, and up to 16 units run in parallel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e7.6 kW hybrid inverter for a 50 Hz grid and one 48 V battery bank\u003c\/h3\u003e\u003cp\u003eIt is rated 7,600 W continuous, with 8,360 VA available on a short peak. One battery bank connects here, charging or discharging at up to 190 A, and the panel array can total 9,880 W. The grid side is set for 50 Hz, 45 to 55 Hz, and 50 A of grid supply passes through to the loads. At 30 kg it is a two-person lift, and it runs at 30 dB.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 7,600 W · Max charge and discharge: 190 A · Max PV input: 9,880 W · Grid frequency: 50 Hz\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7.6K-SG01LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW hybrid inverter for 60 Hz grids, one 48 V battery bank\u003c\/h3\u003e\u003cp\u003eSame 30 kg cabinet and the same 190 A battery current as the 7.6 kW, with two differences that decide the choice on site: it is rated 8,000 W, and its grid side is set for 60 Hz, 55 to 65 Hz. That makes it the unit for markets running at 60 Hz. Panels can total 10,400 W, output current reaches 40 A, and 50 A passes through from the grid when the sun is down.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 8,000 W · Max PV input: 10,400 W · Grid frequency: 60 Hz · Max AC output current: 40 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-SG01LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e12 kW hybrid inverter with two battery inputs for a large villa\u003c\/h3\u003e\u003cp\u003eThis is the step up to the bigger 52 kg cabinet, 464 by 763 by 282 mm. It carries 12,000 W and takes two separate battery banks instead of one, charging or discharging at up to 220 A. Panels can total 24,000 W, twice the AC rating, which keeps output near the ceiling on a dull morning. Grid pass-through doubles to 100 A, so the whole board can sit behind the inverter.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 12,000 W · Battery inputs: 2 · Max PV array: 24,000 W · Weight: 52 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-12K-SG01LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e14 kW hybrid inverter for a big home or a small workshop, 48 V\u003c\/h3\u003e\u003cp\u003eThe middle rating of the large cabinet: 14,000 W continuous, 15,400 VA on peak, and 250 A of battery charge and discharge current. Rated output current is 63.6 A, and the panel array can total 28,000 W. It shares the 52 kg case with the 12 kW and the 16 kW, so a site can be specified up or down a rating without redrawing the wall layout.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 14,000 W · Max charge and discharge: 250 A · Max PV array: 28,000 W · Rated output current: 63.6 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-14K-SG01LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e16 kW hybrid inverter, the largest single-phase unit in the range\u003c\/h3\u003e\u003cp\u003eTop of the family at 16,000 W, or 17,600 VA on peak. Battery current reaches 290 A across its two banks, the highest here, and the panel array can total 32,000 W, so a big roof still has somewhere to put its midday output. Rated output current is 72.7 A. It works on the same 40-60 V bank as the 7.6 kW at the other end of the range.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 16,000 W · Max charge and discharge: 290 A · Max PV array: 32,000 W · Max apparent power: 17,600 VA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-16K-SG01LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 5 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e40-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e96.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003eL+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eColorful Touch LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e2 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e125-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Reverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-40 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"7.6 kW","offer_id":47869739630697,"sku":"SUN-7.6K-SG01LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869739663465,"sku":"SUN-8K-SG01LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true},{"title":"12 kW","offer_id":47869739696233,"sku":"DEYE-SUN-12K-SG01LP1-EU","price":8055.0,"currency_code":"AED","in_stock":true},{"title":"14 kW","offer_id":47869739729001,"sku":"DEYE-SUN-14K-SG01LP1-EU","price":8055.0,"currency_code":"AED","in_stock":true},{"title":"16 kW","offer_id":47869739761769,"sku":"DEYE-SUN-16K-SG01LP1-EU","price":8055.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-12-16K-SG01LP1-EU.png?v=1785851375"},{"product_id":"deye-sun-g05-p3","title":"Deye 15–25 kW Three-Phase Solar Inverter","description":"\u003cp\u003eThe SUN-G05 is Deye's three-phase string inverter for roofs that sell power to the grid rather than store it, from a 15 kW shop roof up to a 25 kW warehouse array. Every rating runs two independent MPPT trackers and holds 98% European efficiency, so the choice comes down to how many panels you have and how much current your board can carry. Pick by array size first, then check the output current against your existing supply.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo independent MPPT trackers on every rating, so a roof split across two pitches runs as two separate strings\u003c\/li\u003e\n\u003cli\u003e98% European efficiency across the whole range, the weighted figure that reflects a real day rather than one peak moment\u003c\/li\u003e\n\u003cli\u003eIP65 sealing lets the unit sit outdoors on a wall, and it keeps working from -25°C to 60°C\u003c\/li\u003e\n\u003cli\u003eCurrent distortion stays under 3% THDi, which is what most utilities ask for on a three-phase connection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e15 kW three-phase string inverter for a small commercial rooftop\u003c\/h3\u003e\u003cp\u003eThe 15 kW is the odd one in this range and the quietest, running under 40 dB where the rest sit at 50 dB. Its two trackers are not matched: one takes 13 A and the other 26 A, and the string ceiling is 1000 V rather than the 1100 V the bigger units allow. You can fit 19.5 kW of panels to it, and it returns 22.7 A per phase at rated output with 16.5 kVA available.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax efficiency: 98.5% · Panel headroom: 19.5 kW · Max string voltage: 1,000 V · Noise: under 40 dB\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-15K-G05\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e18 kW three-phase solar inverter for a 23 kW rooftop panel array\u003c\/h3\u003e\u003cp\u003eStep up from the 15 kW and both trackers take 26 A each, so 23.4 kW of panels can go on the roof and strings may run to 1100 V. It gives 27.3 A per phase at its rated 18 kW, with 19.8 kVA at the ceiling, which is the usual sizing for a workshop or a small hotel. The array needs to reach 500 V before the inverter will hold full output.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanel headroom: 23.4 kW · Max apparent power: 19.8 kVA · Rated output current: 27.3 A per phase · Full-output PV window: 500-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-18K-G05\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e20 kW three-phase grid-tie inverter for a mid-size factory roof\u003c\/h3\u003e\u003cp\u003eIt takes the same 28.6 kW of panels as the 22 kW model but carries a lower AC rating, which makes it the one to pick when the array is generous and the grid connection is not. Rated output is 30.3 A per phase, rising to 22 kVA of apparent power. Its full-output window opens at 500 V, the same as the 18 kW, so a string layout can be copied straight across from that unit.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanel headroom: 28.6 kW · Max apparent power: 22 kVA · Rated output current: 30.3 A per phase · Full-output PV window: 500-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-20K-G05\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e22 kW three-phase string inverter sized for a 28.6 kW solar array\u003c\/h3\u003e\u003cp\u003eThe 22 kW accepts the same 28.6 kW of panels as the 20 kW but converts more of it, giving 33.4 A per phase and 24.2 kVA. Its full-output window starts higher, at 550 V, so strings need an extra module or two compared with a 20 kW build to keep it at rated power through the middle of the day. A sensible choice where the roof is already full and the supply can carry the extra current.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanel headroom: 28.6 kW · Max apparent power: 24.2 kVA · Rated output current: 33.4 A per phase · Full-output PV window: 550-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-22K-G05\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e23 kW three-phase solar inverter for a large warehouse rooftop\u003c\/h3\u003e\u003cp\u003eA narrow step above the 22 kW: 29.9 kW of panels instead of 28.6 kW, and 34.9 A per phase instead of 33.4 A. Peak AC output reaches 38.4 A with 25.3 kVA of apparent power. It shares the 22 kW model's 550 V full-output threshold, so a string design carries over from that unit unchanged, and the extra 1.3 kW of panel headroom is what you are actually buying.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanel headroom: 29.9 kW · Max apparent power: 25.3 kVA · Rated output current: 34.9 A per phase · Peak AC current: 38.4 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-23K-G05\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e25 kW three-phase string inverter, the largest G05 on the shelf\u003c\/h3\u003e\u003cp\u003eThe biggest G05 here takes 32.5 kW of panels, close to 40% more than the 18 kW, and returns 37.9 A per phase at its rated 25 kW. Apparent power tops out at 27.5 kVA and peak AC current at 41.7 A, so the outgoing breaker and cable want sizing against that figure, not against the 25 kW on the label. It suits a full factory or warehouse roof on a three-phase supply.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanel headroom: 32.5 kW · Max apparent power: 27.5 kVA · Rated output current: 37.9 A per phase · Peak AC current: 41.7 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-25K-G05\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 6 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\/45Hz-55Hz, 60Hz\/55Hz-65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380,230\/400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC),OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eDC Injection Current: \u0026lt;0.5%In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"15 kW","offer_id":47869739794537,"sku":"DEYE-SUN-15K-G05","price":6399.0,"currency_code":"AED","in_stock":true},{"title":"18 kW","offer_id":47869739827305,"sku":"DEYE-SUN-18K-G05","price":8750.0,"currency_code":"AED","in_stock":true},{"title":"20 kW","offer_id":47869739860073,"sku":"DEYE-SUN-20K-G05","price":8750.0,"currency_code":"AED","in_stock":true},{"title":"22 kW","offer_id":47869739892841,"sku":"DEYE-SUN-22K-G05","price":8750.0,"currency_code":"AED","in_stock":true},{"title":"23 kW","offer_id":47869739925609,"sku":"DEYE-SUN-23K-G05","price":8750.0,"currency_code":"AED","in_stock":true},{"title":"25 kW","offer_id":47869739958377,"sku":"DEYE-SUN-25K-G05","price":8750.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-15K-G05.png?v=1785851378"},{"product_id":"deye-sun-g04-lv-p3","title":"Deye 18–21 kW Three-Phase Low-Voltage Solar Inverter","description":"\u003cp\u003eThese are three-phase solar inverters for low-voltage grids, the 127\/220 V and 133\/230 V supplies used in parts of Latin America and on older industrial sites. All three run at 98.6% peak efficiency with two independent MPPT trackers, so a roof split across two orientations still gets tracked properly. The choice between 18, 20 and 21 kW comes down to array size and, in one case, the size of the box going on the wall.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e98.6% peak efficiency and a 98.1% European weighted average at every rating.\u003c\/li\u003e\n\u003cli\u003eTwo independent MPPT trackers with a 200 to 700 V window and 40 A per input.\u003c\/li\u003e\n\u003cli\u003eWakes at 250 V and takes up to 800 V from the array.\u003c\/li\u003e\n\u003cli\u003eIP65 sealed and rated from -25 to 65 C, so an outdoor wall in real heat is fine.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e18 kW three-phase LV inverter with a 250 V full-load MPPT floor\u003c\/h3\u003e\u003cp\u003eRated 18 kW with room for 27 kW of panels and 47.3 A per phase. Its useful trick is the full-load MPPT window, which starts at 250 V rather than the 300 V of the 20 and 21 kW units, so it holds full output on a shorter string or on a cold, overcast morning. Maximum output fault current is 90.4 A. The cabinet weighs 51.9 kg.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 18 kW · Max PV input power: 27 kW · Max AC output current: 47.3 A · Full-load MPPT range: 250-700 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-18K-G04-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e20 kW three-phase low-voltage inverter for a 30 kW rooftop array\u003c\/h3\u003e\u003cp\u003eRated 20 kW and taking up to 30 kW of panels, with 52.5 A per phase. Its full-load MPPT window starts at 300 V, so it expects a longer string than the 18 kW model. Maximum output fault current is 100.4 A, which is the number your electrician needs when sizing the AC protection. It uses the same 51.9 kg cabinet as the 18 kW unit, so the mounting is identical.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 20 kW · Max PV input power: 30 kW · Max AC output current: 52.5 A · Max output fault current: 100.4 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-20K-G04-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e21 kW three-phase LV solar inverter in a lighter 23 kg cabinet\u003c\/h3\u003e\u003cp\u003eThe largest of the three, rated 21 kW with 31.5 kW of panel capacity and 55.2 A per phase. It is also the odd one out physically: 23 kg in a 362 x 577 x 215 mm case, against 51.9 kg and 456 x 750 x 268.5 mm for the 18 and 20 kW units. That changes what two people can lift onto a wall unaided. Maximum output fault current is 105.4 A.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 21 kW · Max PV input power: 31.5 kW · Max AC output current: 55.2 A · Weight: 23 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-21K-G04-LV\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 3 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFCI Protection\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e2\/3+3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNBR 16149, NBR 16150, EN 50549, RD 140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC),OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\/45Hz-55Hz, 60Hz\/55Hz-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC),TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD1602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e28.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e330 x 572 x 206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eDC Injection Current: \u0026lt;0.5%In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"18 kW","offer_id":47869740023913,"sku":"DEYE-SUN-18K-G04-LV","price":7350.0,"currency_code":"AED","in_stock":true},{"title":"20 kW","offer_id":47869740056681,"sku":"DEYE-SUN-20K-G04-LV","price":7350.0,"currency_code":"AED","in_stock":true},{"title":"21 kW","offer_id":47869740089449,"sku":"DEYE-SUN-21K-G04-LV","price":7350.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-18-21K-G04-LV.png?v=1785851380"},{"product_id":"deye-sun-sg01hp3-eu-bm3","title":"Deye 29.9–35 kW Three-Phase High-Voltage Hybrid Solar Inverter","description":"\u003cp\u003eThe SG01HP3 is Deye's three-phase hybrid inverter for commercial roofs, farms and workshops, built around a high-voltage battery rather than a 48 V one. Three ratings are offered, 29.9 kW, 30 kW and 35 kW, and all of them charge and discharge at 100 A across two battery inputs. Ten units can be wired in parallel when one is not enough.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRuns a high-voltage battery from 160 V to 800 V, on two inputs of 50 A each\u003c\/li\u003e\n\u003cli\u003ePasses 200 A of grid current through to the loads, and holds 1.5 times rated power for 10 seconds off-grid\u003c\/li\u003e\n\u003cli\u003eTen units in parallel, with 100% unbalanced output so a single phase can carry the whole load\u003c\/li\u003e\n\u003cli\u003e80 kg IP65 cabinet, air-cooled, rated from -40 to +60 C and up to 2000 m altitude\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e29.9 kW three-phase hybrid inverter capped at 29,900 VA for grid rules\u003c\/h3\u003e\u003cp\u003eThe 29.9 kW exists for one reason: many grid operators cap a connection at 30 kVA, and this model's apparent output is held to exactly 29,900 VA instead of being oversized above its rating. It takes 59,800 W of panels, 38,870 W of DC input power, and puts out 45.4 A per phase. If the utility paperwork carries a 30 kVA limit, this is the version that clears it without an argument.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eApparent power: 29,900 VA · Max panel array: 59,800 W · Max AC output current: 45.4 A · Max DC input power: 38,870 W\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-29.9K-SG01HP3-EU-BM3\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e30 kW three-phase high-voltage hybrid inverter, 33 kVA apparent output\u003c\/h3\u003e\u003cp\u003eSame 30 kW class, but the apparent output runs to 33,000 VA, so it can push 50 A per phase when the sun is strong and the battery is helping. Panel capacity is 60,000 W with 39,000 W of DC input. Choose it over the 29.9 kW anywhere the grid connection is not capped, since the extra 3,100 VA of headroom comes in the same 80 kg cabinet at the same size.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eApparent power: 33,000 VA · Max panel array: 60,000 W · Max AC output current: 50 A · Max DC input power: 39,000 W\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-30K-SG01HP3-EU-BM3\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e35 kW three-phase hybrid solar inverter for a 70 kW panel array\u003c\/h3\u003e\u003cp\u003eThe biggest of the three, at 38,500 VA and 58.4 A per phase, fed by as much as 70,000 W of panels and 45,500 W of DC input. One point to watch in the string design: at full load its tracking window starts at 420 V rather than the 360 V of the two smaller models, so strings need a few more modules to hold rated output. The cabinet is unchanged at 80 kg.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eApparent power: 38,500 VA · Max panel array: 70,000 W · Max AC output current: 58.4 A · Max DC input power: 45,500 W\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-35K-SG01HP3-EU-BM3\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 3 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charge Discharge Current (A)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Over Current Protection (A)\u003c\/td\u003e\n\u003ctd\u003e144.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e3\/2+2+2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e180-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e160-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eWIFI, RS485, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charge Current (A)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Passthrough (A)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Discharge Current (A)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e1.5 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalanced Output (%)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-40 to +60℃, \u0026gt;45℃ Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e527 x 894 x 294\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"29.9 kW","offer_id":47869740154985,"sku":"SUN-29.9K-SG01HP3-EU-BM3","price":16844.0,"currency_code":"AED","in_stock":true},{"title":"30 kW","offer_id":47869740187753,"sku":"SUN-30K-SG01HP3-EU-BM3","price":16844.0,"currency_code":"AED","in_stock":true},{"title":"35 kW","offer_id":47869740220521,"sku":"SUN-35K-SG01HP3-EU-BM3","price":16844.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-29.9-35K-SG01HP3.png?v=1785851382"},{"product_id":"deye-sun-g05p1-eu-am2","title":"Deye 3.6–6.2 kW Single-Phase Solar Inverter","description":"\u003cp\u003eA single-phase solar inverter for a house, a villa or a small shop on a normal 230 V supply. All eight ratings sit in the same small 7.7 kg case, so the size you pick is decided by how many panels are going on the roof and what the utility lets you export. There is no battery here: sunlight goes to the loads first, and the rest to the grid.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo independent trackers with a 70 to 500 V window and 18 A per string, so two roof faces can share one inverter\u003c\/li\u003e\n\u003cli\u003eWakes up at 80 V, so it starts making a little power early in the morning and keeps going late\u003c\/li\u003e\n\u003cli\u003e7.7 kg in a 305 x 280 x 180 mm case, light enough for one person to lift onto the bracket\u003c\/li\u003e\n\u003cli\u003eNo fan: natural cooling keeps it under 35 dB, and IP65 lets it live outdoors at up to 3,000 m\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3.6 kW single-phase inverter for a small home roof, 4.7 kW of panels\u003c\/h3\u003e\u003cp\u003eThe smallest of the eight, sized for a modest house roof. It takes 4.7 kW of panels and puts out 3.96 kVA, up to 18 A on the AC side and 16.4 A at the rated point. Deye rates it at 97.3% peak efficiency and 96.9% European efficiency, marginally below its bigger siblings. It is the one to pick where the export limit or the meter caps you near 3.6 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 3.6 kW · Max PV input: 4.7 kW · Max AC output current: 18 A · Max efficiency: 97.3%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3.6K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e4 kW single-phase solar inverter for a 5.2 kW rooftop array\u003c\/h3\u003e\u003cp\u003eA round 4 kW rating that suits a typical family house with about a dozen panels. It carries 5.2 kW of panels, 4.4 kVA of apparent power and 20 A maximum on the AC side, with 18.2 A at the rated point. European efficiency is quoted at 96.9%. Choose it over the 3.6 kW when the roof has room for another string but the supply is still a standard single-phase connection.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 4 kW · Max PV input: 5.2 kW · Max AC output current: 20 A · Apparent power: 4.4 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-4K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e4.2 kW single-phase inverter, 5.5 kW of panels and 97% Euro efficiency\u003c\/h3\u003e\u003cp\u003eA 4.2 kW rating that exists mainly for grid rules that cap export just above 4 kW. It accepts 5.5 kW of panels, delivers 4.62 kVA and reaches 21 A on the AC side, with 19.1 A rated. Only the 3.6 kW sits lower, at 97.3% peak; from 4 kW upward Deye quotes 97.5% peak and 97.0% European efficiency.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 4.2 kW · Max PV input: 5.5 kW · Max AC output current: 21 A · Euro efficiency: 97.0%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-4.2K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e4.6 kW single-phase inverter for a 6 kW roof under a 5 kW export cap\u003c\/h3\u003e\u003cp\u003eThe 4.6 kW is the common answer where a utility allows a little under 5 kW of export. It takes a full 6 kW of panels, gives 5.06 kVA and tops out at 23 A on the AC side, with 21 A at the rated point. Peak efficiency is 97.5%. Because 6 kW of panels against 4.6 kW of output is a healthy oversize, it holds full output for longer through the middle of the day.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 4.6 kW · Max PV input: 6 kW · Max AC output current: 23 A · Apparent power: 5.06 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-4.6K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5 kW single-phase solar inverter for a 6.5 kW home array\u003c\/h3\u003e\u003cp\u003eThe most asked for size in the range: 5 kW of output for a family house with air conditioning. It handles 6.5 kW of panels, 5.5 kVA of apparent power and 25 A maximum on the AC side, with 22.8 A at the rated point, so the AC circuit has to be sized for it. Peak efficiency is 97.5%, and it still weighs the same 7.7 kg as the 3.6 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 5 kW · Max PV input: 6.5 kW · Max AC output current: 25 A · Apparent power: 5.5 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5.2 kW single-phase inverter, 6.8 kW of panels and 26 A output\u003c\/h3\u003e\u003cp\u003eA 5.2 kW step for roofs that came out slightly larger than a 5 kW design. It accepts 6.8 kW of panels, gives 5.72 kVA and reaches 26 A on the AC side against 23.7 A at the rated point. Everything else, from the two trackers to the 550 V string limit, matches the 5 kW, so the extra 300 W of panel capacity is the only practical gain.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 5.2 kW · Max PV input: 6.8 kW · Max AC output current: 26 A · Rated AC current: 23.7 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5.2K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW single-phase inverter for a large villa roof, 7.8 kW of panels\u003c\/h3\u003e\u003cp\u003eA 6 kW unit for a large villa or a shop that runs through the afternoon. It takes 7.8 kW of panels, 6.6 kVA of apparent power and 30 A maximum on the AC side, with 27.3 A rated, which is enough current that the AC cable and breaker need checking before install. It still cools itself with no fan and still weighs 7.7 kg.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 6 kW · Max PV input: 7.8 kW · Max AC output current: 30 A · Apparent power: 6.6 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6.2 kW single-phase inverter, the biggest in Deye's G05P1 range\u003c\/h3\u003e\u003cp\u003eThe largest single-phase unit here, for the roof that has run out of space rather than ambition. It carries 8.1 kW of panels, 6.82 kVA and 31 A maximum on the AC side, with 28.2 A at the rated point. Past this size Deye's answer is a three-phase machine, so if the property has three phases available it is worth comparing before ordering.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 6.2 kW · Max PV input: 8.1 kW · Max AC output current: 31 A · Rated AC current: 28.2 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6.2K-G05P1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 8 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e70-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e2\/1+1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e80-550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232 \/WiFi\/LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Operating Current (A)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eNatural cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to +60℃, \u0026gt;45℃ Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e7.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e305 x 280 x 180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"3.6 kW","offer_id":47869740286057,"sku":"SUN-3.6K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"4 kW","offer_id":47869740318825,"sku":"SUN-4K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"4.2 kW","offer_id":47869740351593,"sku":"SUN-4.2K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"4.6 kW","offer_id":47869740384361,"sku":"SUN-4.6K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"5 kW","offer_id":47869740417129,"sku":"SUN-5K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"5.2 kW","offer_id":47869740449897,"sku":"SUN-5.2K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869740482665,"sku":"SUN-6K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true},{"title":"6.2 kW","offer_id":47869740515433,"sku":"SUN-6.2K-G05P1-EU-AM2","price":2126.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-3.6-6.2K-G05P1.png?v=1785851385"},{"product_id":"deye-sun-og01lp1-eu-am2","title":"Deye 3.6–6 kW Single-Phase Low-Voltage Off-Grid Solar Inverter","description":"\u003cp\u003eDeye's single-phase off-grid solar inverter runs a house that has no utility supply, or one where the supply cannot be trusted, from panels and a 48V battery bank. It comes in 3.6, 5 and 6 kW, all delivering 230V pure sine wave power that appliances and motors treat exactly like mains. A diesel generator can be wired in as a third source, and up to 16 of these can work side by side as the site grows.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRuns the house on its own from a 48V battery bank (40 to 60 V), lead acid or lithium\u003c\/li\u003e\n\u003cli\u003eTwo panel trackers, 18 A each, feeding a 230V pure sine output at 50 or 60 Hz\u003c\/li\u003e\n\u003cli\u003eCarries twice its rated power for 10 seconds, which is what a fridge or a pump asks for at start-up\u003c\/li\u003e\n\u003cli\u003e12.2 kg, IP65, starts in anything from -40C to 60C, and up to 16 units can share one site\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3.6 kW off-grid solar inverter for a cabin or a two-room house\u003c\/h3\u003e\u003cp\u003eThe smallest of the three carries 3.6 kW of continuous load and charges or discharges the battery at up to 90 A. Panels can total 7,200 W, of which 5,760 W is converted, and its own PV window reaches down to 125 V, which suits the short strings a small roof gives you. Apparent power is 3,960 VA. Sensible for lighting, a fridge, fans and a television rather than air conditioning.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels supported: 7,200 W · Max PV input power: 5,760 W · Battery charge and discharge: 90 A · Max AC output current: 15.7 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3.6K-OG01LP1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5 kW off-grid inverter for a family home running on batteries alone\u003c\/h3\u003e\u003cp\u003eThe 5 kW handles 21.8 A of output current and moves 120 A in and out of the battery, a third more than the 3.6 kW, so a bank recharges faster on a short sunny window. It accepts 10,000 W of panels and converts up to 8,000 W of that. This is the size most family homes land on once a washing machine and a single air conditioner are on the list.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels supported: 10,000 W · Max PV input power: 8,000 W · Battery charge and discharge: 120 A · Max AC output current: 21.8 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-OG01LP1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW off-grid solar inverter for a home with a well pump or AC unit\u003c\/h3\u003e\u003cp\u003eThe 6 kW is the strongest of the three: 26.1 A of output, 135 A of battery charge current and room for 12,000 W of panels, 9,600 W of which reaches the conversion stage. That charge rate refills a large bank in the hours around noon, which matters on a farm or a site where a borehole pump has to run every day. Same 12.2 kg box as the 3.6 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels supported: 12,000 W · Max PV input power: 9,600 W · Battery charge and discharge: 135 A · Max AC output current: 26.1 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-OG01LP1-EU-AM2\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 3 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e2\/1+1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLead-acid or Lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e40-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\/CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e96.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Full Load Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e300-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Grid Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e2 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e125-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e12.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eColorful Touch LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e306 x 427.5 x 175.77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"3.6 kW","offer_id":47869740548201,"sku":"SUN-3.6K-OG01LP1-EU-AM2","price":2633.0,"currency_code":"AED","in_stock":true},{"title":"5 kW","offer_id":47869740580969,"sku":"SUN-5K-OG01LP1-EU-AM2","price":2633.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869740613737,"sku":"SUN-6K-OG01LP1-EU-AM2","price":2633.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-3.6-6K-OG01LP1.png?v=1785851387"},{"product_id":"deye-sun-sg04lp1-eu","title":"Deye 3 kW Single-Phase Low-Voltage Hybrid Solar Inverter","description":"\u003cp\u003eThe SG04LP1 is Deye's single-phase hybrid solar inverter, the box that ties panels, battery and grid together in one wall-mounted unit. Four models are sold here off one datasheet: a 3 kW built for a 24 V battery bank, then 3 kW, 5 kW and 6 kW for the usual 48 V one. What separates them is how fast each moves power into a battery and what battery it expects. All four share the same 97.6% conversion, the same colour touch screen and the same IP65 case.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e97.6% conversion at best and 96.5% on the European weighting, whichever rating you pick\u003c\/li\u003e\n\u003cli\u003eSealed for an outdoor wall (IP65), quiet at under 30 dB, and rated from -40 C to +60 C\u003c\/li\u003e\n\u003cli\u003eDoubles its rated output for 10 seconds off grid, which is what starts a pump or a fridge\u003c\/li\u003e\n\u003cli\u003eAbout 17 kg at 330 x 433 x 228 mm, colour touch screen, with Wi-Fi, RS485 and CAN on board\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3 kW single-phase hybrid solar inverter for a 24V battery bank home\u003c\/h3\u003e\u003cp\u003eOne model, one battery voltage: 3,000 W of continuous output, 3,300 VA at peak and 70 A of charge or discharge into a 24V bank. Panels can reach 4,800 W, tracked over a 150 to 425 V window. Off grid it will hold double its rating for 10 seconds to get a motor spinning. At 17.6 kg and sealed to IP65 it mounts inside or out, and the battery side is isolated from the solar side.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 3,000 W · Max apparent power: 3,300 VA · Battery charge and discharge: 70 A · Max panel input: 4,800 W\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3K-SG04LP1-24\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e3 kW single-phase hybrid inverter for a 48 V bank and 4.8 kW of panels\u003c\/h3\u003e\u003cp\u003eThe smallest of the four 48 V models: a 40 V to 60 V battery window, 3,000 W of rated AC output and 3,300 VA apparent. Charge and discharge are limited to 70 A, which is the real difference from the 5 kW and 6 kW units, and up to 4,800 W of panels can feed it across two trackers. Rated output current is 13.6 A in and 13 A out, with 35 A of grid passthrough.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery voltage window: 40-60 V · Max charge and discharge current: 70 A · Max PV input: 4,800 W · Rated AC output: 3,000 W\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3K-SG04LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5 kW single-phase hybrid inverter, 48 V battery and 120 A charging\u003c\/h3\u003e\u003cp\u003eThe middle rating and the usual pick for a home on a 48 V lithium bank, since it works across a 40 V to 60 V battery window. It charges or discharges at up to 120 A, so a typical 5 kWh to 10 kWh bank fills inside a couple of hours of good sun, and it accepts 8,000 W of panels against 5,000 W of output. Normal output current is 22.7 A. There is no fan in this one.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery voltage window: 40-60 V · Max charge and discharge current: 120 A · Max PV input: 8,000 W · Rated output current: 22.7 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-SG04LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW single-phase hybrid inverter with 135 A charging for a 48 V bank\u003c\/h3\u003e\u003cp\u003eThe largest of the four, and the only one with intelligent air cooling, a fan that comes on under load instead of relying on the case alone. Battery current rises to 135 A on the same 40 V to 60 V window, panel input to 9,600 W, and apparent power to 6,600 VA. Normal output is 27.3 A with 30 A at the ceiling, which is the figure your main breaker has to clear.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax charge and discharge current: 135 A · Max PV input: 9,600 W · Max apparent power: 6,600 VA · Cooling: Intelligent air cooling (fan)\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-SG04LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 4 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e125-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLead-acid or Lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e96.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Full Load Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e300-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003eL+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/230V 0.85Un-1.1Un L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e2 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eWIFI, RS485, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097, RD4105140, UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e330 x 433 x 228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"3 kW \/ 24 V","offer_id":47921858609257,"sku":"DEYE-SUN-3K-SG04LP1-24","price":2605.0,"currency_code":"AED","in_stock":true},{"title":"3 kW \/ 48 V","offer_id":47921858642025,"sku":"DEYE-SUN-3K-SG04LP1-EU","price":3211.0,"currency_code":"AED","in_stock":true},{"title":"5 kW \/ 48 V","offer_id":47921858674793,"sku":"DEYE-SUN-5K-SG04LP1-EU","price":3211.0,"currency_code":"AED","in_stock":true},{"title":"6 kW \/ 48 V","offer_id":47921858707561,"sku":"DEYE-SUN-6K-SG04LP1-EU","price":3211.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-3-6K-SG04LP1.png?v=1785851389"},{"product_id":"deye-sun-sg05lp1-eu","title":"Deye 3.6–8 kW Single-Phase Low-Voltage Hybrid Solar Inverter","description":"\u003cp\u003eThe SG05LP1 is Deye's single-phase hybrid inverter for a house with a 48 V battery: it runs the panels, charges the bank and keeps the lights on when the grid drops, all from one wall box. Six ratings cover 3.6 kW to 8 kW, and what separates them is how fast they charge and how many panels they will take. Every one of them works with lead-acid or lithium banks between 40 V and 60 V.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo MPPT trackers over a 150 V to 425 V window, 500 V maximum panel voltage\u003c\/li\u003e\n\u003cli\u003eTakes a 40 V to 60 V lead-acid or lithium bank, and up to 16 units run in parallel\u003c\/li\u003e\n\u003cli\u003e97.6% peak efficiency, 96.5% on the European weighted scale, twice rated power for 10 s\u003c\/li\u003e\n\u003cli\u003eIP65 case, fan cooling measured at 30 dB, colour touch screen, 24.9 kg on the wall\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3.6 kW hybrid inverter for a small home, 90 A battery charge rate\u003c\/h3\u003e\u003cp\u003eThe smallest of the six. It charges and discharges the battery at up to 90 A, takes 5,760 W of panel input with 7,200 W of array allowed, and passes 35 A of grid current through to the house. Rated output is 16.4 A, or 3,960 VA at peak. A fit for a flat or a two-bedroom house where the evening load is lights, a fridge and a room or two of cooling.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery charge and discharge: 90 A · Max PV input power: 5,760 W · Grid passthrough: 35 A · Rated output current: 16.4 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-3.6K-SG05LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e5 kW single-phase hybrid inverter with 120 A charging for a villa\u003c\/h3\u003e\u003cp\u003eThe size most homes settle on. Charge and discharge climb to 120 A, a third more than the 3.6 kW, so a bank refills noticeably faster on a short sunny window. It takes 8,000 W of panels with 10,000 W of array allowed and puts out 22.7 A. Grid passthrough is still 35 A, the same as the 3.6 kW, so the incoming supply usually needs no change.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery charge and discharge: 120 A · Max PV input power: 8,000 W · Grid passthrough: 35 A · Rated output current: 22.7 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-SG05LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW hybrid solar inverter, 135 A charging and 40 A grid passthrough\u003c\/h3\u003e\u003cp\u003eThe first model in the range with 40 A of grid passthrough rather than 35 A, which matters when the whole house sits behind the inverter instead of a small backup board. Battery current rises to 135 A and panel input to 9,600 W, with 12,000 W of array permitted. Rated output is 27.3 A at 6,600 VA. Good for a four-bedroom house with two or three air conditioners.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery charge and discharge: 135 A · Max PV input power: 9,600 W · Grid passthrough: 40 A · Rated output current: 27.3 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-SG05LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7 kW hybrid inverter with doubled 26 A panel input and 175 A charging\u003c\/h3\u003e\u003cp\u003eFrom 7 kW upward the DC side is doubled: 26 A of panel input current and 34 A of short-circuit current, against 13 A and 17 A on the 3.6 kW to 6 kW models, so more strings land on the same unit. Battery current is 175 A and panel input 11,200 W, with 14,000 W of array allowed. Rated output is 31.9 A at 7,700 VA.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery charge and discharge: 175 A · Max PV input power: 11,200 W · Max PV input current: 26 A · Rated output current: 31.9 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7K-SG05LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7.6 kW single-phase hybrid inverter with 50 A of grid passthrough\u003c\/h3\u003e\u003cp\u003eThe 7.6 kW raises grid passthrough to 50 A, ten more than the 7 kW, and takes battery current to 190 A. Panel input is 12,160 W with 15,200 W of array allowed, and rated output is 34.5 A at 8,360 VA. The 0.6 kW gap over the 7 kW is small, so decide between the two on the passthrough figure and on what the main breaker will carry.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery charge and discharge: 190 A · Max PV input power: 12,160 W · Grid passthrough: 50 A · Rated output current: 34.5 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7.6K-SG05LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW single-phase hybrid inverter, the largest of the six ratings here\u003c\/h3\u003e\u003cp\u003eThe top of the range. Battery current is 190 A, the same as the 7.6 kW, so the two differ on the solar and output side: 12,800 W of panel input against 12,160 W, 16,000 W of array allowed, and 36.4 A of rated output at 8,800 VA. Take this one because the roof is already full and you want every panel working, not because you need faster charging.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eBattery charge and discharge: 190 A · Max PV input power: 12,800 W · Max PV array power: 16,000 W · Rated output current: 36.4 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-SG05LP1-EU\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 6 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLead-acid or Lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e40-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eWIFI,RS485,CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e96.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003eL+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IECOVE-Richtlinie62116,CEI0-21,R25,ENG98,50549,G99,NRSVDE-AR-N097,RD4105140, UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eColorful Touch LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/230 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e2 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e125-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-40 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e24.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e330 x 580 x 232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"3.6 kW","offer_id":47869740744809,"sku":"SUN-3.6K-SG05LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true},{"title":"5 kW","offer_id":47869740777577,"sku":"SUN-5K-SG05LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869740810345,"sku":"SUN-6K-SG05LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true},{"title":"7 kW","offer_id":47869740843113,"sku":"SUN-7K-SG05LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true},{"title":"7.6 kW","offer_id":47869740875881,"sku":"SUN-7.6K-SG05LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869740908649,"sku":"SUN-8K-SG05LP1-EU","price":6135.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-3.6-10K-SG05LP1.png?v=1785851391"},{"product_id":"deye-sun-g04-p3","title":"Deye 30–50 kW Three-Phase Solar Inverter","description":"\u003cp\u003eThe Deye G04 three-phase solar inverter is a grid-tied machine for commercial roofs: it turns panel output into 400 V three-phase power and feeds it straight into the building, with no battery involved. Seven ratings run from 30 kW to 50 kW, and the practical difference between them is how much panel each one can take and how many separate roof faces it can track independently.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEuropean weighted efficiency of 98.1% on every rating in the group\u003c\/li\u003e\n\u003cli\u003eStrings up to 1,100 V, tracked anywhere between 200 V and 1,000 V\u003c\/li\u003e\n\u003cli\u003eStarts producing from 250 V and holds current distortion below 3%\u003c\/li\u003e\n\u003cli\u003eIP65 enclosure rated from -25 C to 60 C for rooftop or plant-room mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e30 kW three-phase grid-tied solar inverter for a 45 kW commercial roof\u003c\/h3\u003e\u003cp\u003eThe entry point of the G04 line takes up to 45 kW of panel against a 30 kW output, a 1.5 times oversize that only the 36 kW model matches. Two independent inputs of 40 A each let you split the array across two roof faces. It puts out 33 kVA and 50 A per phase, peaks at 98.6% efficiency, and weighs 23 kg.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 45 kW · PV inputs: 2 x 40 A · Max AC output current: 50 A · Weight: 23 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-30K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e33 kW three-phase solar inverter, 42.9 kW panel input, two trackers\u003c\/h3\u003e\u003cp\u003eThe 33 kW and the 35 kW share a datasheet column, so their output currents are quoted together rather than separately. What clearly separates them is the array: this one is specified for 42.9 kW of panel, 2.6 kW less than the 35 kW. Two 40 A inputs, full output from 500 V upward, 98.6% peak efficiency, and an altitude rating of 4,000 m for highland sites.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 42.9 kW · PV inputs: 2 x 40 A · Full-load tracking window: 500 to 850 V · Max altitude: 4,000 m\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-33K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e35 kW three-phase solar inverter with 45.5 kW of panel input allowed\u003c\/h3\u003e\u003cp\u003eTwo extra kilowatts of output over the 33 kW, and 45.5 kW of panel rather than 42.9 kW. Deye publishes one shared current column for the two models, so we do not quote a separate output current here; the honest difference is rated power and array size. A 23 kg wall case, a pair of 40 A inputs, a 4,000 m altitude rating and 98.6% peak efficiency.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 45.5 kW · PV inputs: 2 x 40 A · Weight: 23 kg · Max efficiency: 98.6%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-35K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e36 kW three-phase solar inverter, 54 kW panel input on two trackers\u003c\/h3\u003e\u003cp\u003eThis is the last of the two-tracker frames and carries the most panel of that group: 54 kW feeding a 36 kW output. Useful on east and west roofs where neither side peaks at once. It delivers 39.6 kVA and 60 A per phase from a 23 kg case, and holds full output from 500 V upward. Fault current is quoted at 104.4 A, which your protection device needs to clear.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 54 kW · Max apparent power: 39.6 kVA · Max AC output current: 60 A · PV inputs: 2 x 40 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-36K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e40 kW three-phase solar inverter with three MPP trackers, 98.7% peak\u003c\/h3\u003e\u003cp\u003eA third independent PV input arrives at 40 kW, so the array can be split three ways across roofs facing different directions without losing yield on the shaded one. Peak efficiency also rises to 98.7%. Output is 44 kVA and 66.7 A per phase, panel input is capped at 52 kW, and the unit runs under 50 dB, quiet enough for a plant room next to offices. It weighs 37.1 kg.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 52 kW · PV inputs: 3 x 40 A · Max AC output current: 66.7 A · Noise: under 50 dB\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-40K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e45 kW three-phase solar inverter, 58.5 kW panel, three MPP trackers\u003c\/h3\u003e\u003cp\u003eThree 40 A inputs again, but a much larger frame: 698 by 613 by 236.5 mm and 53.7 kg, the same weight as the 33 kW. It accepts 58.5 kW of panel, gives 49.5 kVA and 75 A per phase, and holds 98.7% peak efficiency. Check the wall or frame it goes on before ordering, because the extra 16.6 kg over the 40 kW changes the fixing.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 58.5 kW · PV inputs: 3 x 40 A · Max AC output current: 75 A · Weight: 53.7 kg\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-45K-G04\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e50 kW three-phase solar inverter with four MPP trackers, 65 kW panel\u003c\/h3\u003e\u003cp\u003eThe largest rating is the only one with four separate 40 A PV inputs, which suits a site with several roof pitches or a car park canopy in sections. It takes 65 kW of panel, the most in the range, and returns 55 kVA and 83.3 A per phase at up to 98.7% efficiency. Fault current is 145 A, so size the AC protection and cable accordingly.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax panel input: 65 kW · PV inputs: 4 x 40 A · Max AC output current: 83.3 A · Max apparent power: 55 kVA\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-50K-G04\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 7 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIECUNE61727,217002,IEC62116,OVE-RichtlinieCEI0-21, ENR25,50549,G99,VDE-AR-NNRS097,RD4105140,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC),OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC),TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"30 kW","offer_id":47869740941417,"sku":"DEYE-SUN-30K-G04","price":3963.0,"currency_code":"AED","in_stock":true},{"title":"33 kW","offer_id":47869740974185,"sku":"DEYE-SUN-33K-G04","price":3963.0,"currency_code":"AED","in_stock":true},{"title":"35 kW","offer_id":47869741006953,"sku":"DEYE-SUN-35K-G04","price":3963.0,"currency_code":"AED","in_stock":true},{"title":"36 kW","offer_id":47869741039721,"sku":"DEYE-SUN-36K-G04","price":3963.0,"currency_code":"AED","in_stock":true},{"title":"40 kW","offer_id":47869741072489,"sku":"DEYE-SUN-40K-G04","price":5689.0,"currency_code":"AED","in_stock":true},{"title":"45 kW","offer_id":47869741105257,"sku":"DEYE-SUN-45K-G04","price":5689.0,"currency_code":"AED","in_stock":true},{"title":"50 kW","offer_id":47869741138025,"sku":"DEYE-SUN-50K-G04","price":5689.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-30-36K-G04.png?v=1785851393"},{"product_id":"deye-sun-g04p3-eu-am4-lv","title":"Deye 33–50 kW Three-Phase Low-Voltage Solar Inverter","description":"\u003cp\u003eThis is Deye's three-phase string inverter for low-voltage grids: the 127\/220 V and 133\/230 V supplies found in Brazil and other markets that never moved to 400 V. Five ratings run from 33 kW to 50 kW, all grid-tied with no battery attached, all with four independent solar inputs. The rating decides the array, because Deye allows 1.5 times the AC power in panels on every model here.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGrid side is 127\/220 V or 133\/230 V three-phase, certified to NBR 16149, NBR 16150 and EN 50549\u003c\/li\u003e\n\u003cli\u003eFour independent solar inputs, 40 A each, tracking 200 to 700 V under an 800 V ceiling\u003c\/li\u003e\n\u003cli\u003ePanels can be oversized to 1.5 times the AC rating on every model in the range\u003c\/li\u003e\n\u003cli\u003eIP65 enclosure, air cooled, 53.7 kg, rated to 65 °C ambient with derating above 45 °C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e33 kW three-phase string inverter for a 220V commercial rooftop\u003c\/h3\u003e\u003cp\u003eThe entry point of the range and the cheapest way into four-tracker solar on a 220 V grid. It puts out 86.7 A per phase and accepts 49.5 kW of panels, at a peak efficiency of 98.6%. Fits a warehouse or supermarket roof where the load runs through daylight hours and nobody plans to add batteries later.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 33 kW · Max AC output current: 86.7 A · Max PV input power: 49.5 kW · Peak efficiency: 98.6%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-33K-G04P3-EU-AM4-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e35 kW three-phase string inverter, 52.5 kW of panels on a 220V grid\u003c\/h3\u003e\u003cp\u003eA 2 kW step over the 33 kW that buys 3 kW more panel headroom, 52.5 kW in total, and 91.9 A per phase at the output. Peak efficiency stays at 98.6%; the 98.7% figure only starts at 40 kW. Choose this one when the roof came out slightly larger than the 33 kW would carry and you would rather not move up a whole size.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 35 kW · Max AC output current: 91.9 A · Max PV input power: 52.5 kW · Peak efficiency: 98.6%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-35K-G04P3-EU-AM4-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e40 kW three-phase string inverter for a factory roof on a 220V grid\u003c\/h3\u003e\u003cp\u003eFirst rating in the range to reach 98.7% peak efficiency, a tenth of a point above the 33 kW and 35 kW. It delivers 105 A per phase and takes 60 kW of panels. At this size the AC cable run and the site's main breaker matter as much as the inverter itself, so have the run sized before you order.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 40 kW · Max AC output current: 105 A · Max PV input power: 60 kW · Peak efficiency: 98.7%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-40K-G04P3-EU-AM4-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e45 kW three-phase string inverter, 67.5 kW array on 127\/220V supply\u003c\/h3\u003e\u003cp\u003eSits between the 40 kW and the 50 kW, and it exists for roofs that overshoot 60 kW of panels without reaching 75 kW. Output is 118.2 A per phase at 98.7% peak efficiency, with 67.5 kW the most PV Deye allows on it. Same cabinet and the same four 40 A inputs as every other rating here, so the only planning change is cable size.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 45 kW · Max AC output current: 118.2 A · Max PV input power: 67.5 kW · Peak efficiency: 98.7%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-45K-G04P3-EU-AM4-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e50 kW three-phase string inverter, the largest LV model at 75 kW PV\u003c\/h3\u003e\u003cp\u003eThe largest in the range: 131.3 A per phase and 75 kW of panels, still on four inputs of 40 A each, still at 98.7% peak efficiency. On a 220 V grid that is a great deal of current out of one machine, so the AC side wants proper sizing and a short run to the board. It is the top of this low-voltage range.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 50 kW · Max AC output current: 131.3 A · Max PV input power: 75 kW · Peak efficiency: 98.7%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-50K-G04P3-EU-AM4-LV\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 5 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Ocp (A)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNBR 16149, NBR 16150, EN 50549, RD 140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V 0.85UN-1.1UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e53.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e698 x 613 x 236.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eDC Injection Current: \u0026lt;0.5%In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"33 kW","offer_id":47869741170793,"sku":"SUN-33K-G04P3-EU-AM4-LV","price":15000.0,"currency_code":"AED","in_stock":true},{"title":"35 kW","offer_id":47869741203561,"sku":"SUN-35K-G04P3-EU-AM4-LV","price":15000.0,"currency_code":"AED","in_stock":true},{"title":"40 kW","offer_id":47869741236329,"sku":"SUN-40K-G04P3-EU-AM4-LV","price":15000.0,"currency_code":"AED","in_stock":true},{"title":"45 kW","offer_id":47869741269097,"sku":"SUN-45K-G04P3-EU-AM4-LV","price":15000.0,"currency_code":"AED","in_stock":true},{"title":"50 kW","offer_id":47869741301865,"sku":"SUN-50K-G04P3-EU-AM4-LV","price":15000.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-33-50K-G04P3-LV.png?v=1785851395"},{"product_id":"deye-sun-sg01lp1-us","title":"Deye 5–8 kW Split-Phase Low-Voltage Hybrid Solar Inverter (SUN-SG01LP1-US)","description":"\u003cp\u003eThe SUN-SG01LP1-US is Deye's split-phase hybrid inverter, wired for a 120\/240 V, 60 Hz supply rather than the 230 V single-phase grid used across most of Europe and the Gulf. Three sizes are sold here, 5, 6 and 8 kW, and each one runs panels, a 48 V battery and the grid at the same time. Buy from this family only if the house is genuinely wired split-phase; on a 230 V grid the SG05LP1 range is the right one.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e120\/240 V split-phase output, 208 V also supported, on a 60 Hz grid\u003c\/li\u003e\n\u003cli\u003eRuns a 40 to 60 V lead-acid or lithium bank from one battery input\u003c\/li\u003e\n\u003cli\u003eTYPE3R outdoor enclosure, under 30 dB, rated from -40 to 60 C\u003c\/li\u003e\n\u003cli\u003e97.6% peak efficiency, two MPPT trackers, up to 16 units in parallel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e5 kW split-phase hybrid inverter for a 120\/240V home backup system\u003c\/h3\u003e\u003cp\u003eThe smallest of the three gives 5,000 W and 5,500 VA, with 24 A of rated output at 120\/240 V. Its two trackers take 13 A each, so total panel input is capped at 6,500 W, the tightest array budget in this group. Battery charge and discharge run to 120 A and grid passthrough is 40 A. It fits a house whose backup list is a fridge, lights, a well pump and one air handler.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 5,000 W · Rated output current: 24 A · Max PV input: 6,500 W · Battery charge and discharge: 120 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-SG01LP1-US\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW split-phase hybrid inverter for a home with 7.8 kW of panels\u003c\/h3\u003e\u003cp\u003eThe 6 kW model gives 6,000 W and 28.8 A of rated output current, and its solar side is deliberately uneven: one tracker takes 26 A while the other takes 13 A, so the two strings are sized differently by design. Total panel input is 7,800 W. Battery charge and discharge rise to 135 A, while grid passthrough stays at 40 A, the same as the 5 kW unit.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 6,000 W · Rated output current: 28.8 A · PV tracker currents: 26 A and 13 A · Max PV input: 7,800 W\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-SG01LP1-US\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW split-phase hybrid inverter for a large 120\/240V house or shop\u003c\/h3\u003e\u003cp\u003eAt 8,000 W and 8,800 VA it puts out 38.5 A of rated current, and both trackers now take the full 26 A, giving a 10,400 W panel budget. Battery charge and discharge reach 190 A and grid passthrough steps up to 50 A. Full-load tracking starts at 200 V rather than the 300 V of the smaller two, which helps on cold bright mornings when string voltage is still climbing.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 8,000 W · Rated output current: 38.5 A · Max PV input: 10,400 W · Grid passthrough: 50 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-SG01LP1-US\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 3 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e60Hz\/55Hz-65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e125-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLead-acid or Lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e40-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS232, RS485, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e2L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eEN 50549,UNE 217002,NRS 097,IEEE 1547.1,SRD V2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC IV(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Hz)\u003c\/td\u003e\n\u003ctd\u003e60Hz\/55Hz-65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e120\/240V; 208V 0.88Un\u0026lt;U\u0026lt;1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4,FCC,ULIEC\/EN174162109-1, IEC\/EN 62109-2,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e2 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e120\/240V, 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eTYPE3R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eColorful Touch LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-40 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e420 x 670 x 233\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eCharging Strategy for Li-Ion Battery: Self-adaption to BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"5 kW","offer_id":47869741334633,"sku":"DEYE-SUN-5K-SG01LP1-US","price":5323.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869741367401,"sku":"DEYE-SUN-6K-SG01LP1-US","price":5323.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869741400169,"sku":"DEYE-SUN-8K-SG01LP1-US","price":5323.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-5-8K-SG01LP1-US.png?v=1785851397"},{"product_id":"deye-sun-sg02lp2-us-am2","title":"Deye 5–8 kW Split-Phase Low-Voltage Hybrid Solar Inverter (SUN-SG02LP2-US-AM2)","description":"\u003cp\u003eThe SUN-SG02LP2-US-AM2 is a split-phase hybrid inverter, which means it puts out 120 V and 240 V at the same time on a two-line supply with neutral, rather than the single 230 V used across Europe and the Gulf. Four sizes cover 5 kW to 8 kW. All of them charge a 48 V battery, all accept a diesel generator as a second source, and up to sixteen can be paralleled on one site.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutput is 120\/240 V split phase, with 208 V also supported, and each unit weighs 35.6 kg.\u003c\/li\u003e\n\u003cli\u003e97.6% peak efficiency and 96.5% on the European weighted measure, with two trackers working from 150 to 425 V.\u003c\/li\u003e\n\u003cli\u003eThe case is sealed to IP65, the unit is quiet at 45 dB, and it is specified from -40 to 60 C and up to 2,000 m.\u003c\/li\u003e\n\u003cli\u003eSixteen units run in parallel, and every size takes a generator input as well as the grid.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e5 kW split-phase hybrid inverter for a 120\/240 V home with a 48 V bank\u003c\/h3\u003e\u003cp\u003eThe smallest of the four. It carries 7,500 W of panels, 5,000 VA of output and 20.9 A per leg, and charges the battery at up to 120 A. Grid passthrough to the loads is 35 A, the lowest in this group, so check the main breaker feeding the house before settling on it. Full load tracking runs from 300 to 425 V, the same window as the 6 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 120 A · Max PV input power: 7,500 W · Max AC output current: 20.9 A · Grid passthrough: 35 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-5K-SG02LP2-US-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e6 kW split-phase hybrid inverter for a house with two air conditioners\u003c\/h3\u003e\u003cp\u003eOne step up, and much of the step is in what passes through. Output is 6,000 VA at 25 A per leg, charging rises to 135 A, and grid passthrough to the loads goes from 35 A to 40 A. The array can reach 9,000 W. Tracking at full load uses the same 300 to 425 V window as the 5 kW, so a string layout drawn for that model carries over unchanged.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 135 A · Max PV input power: 9,000 W · Max AC output current: 25 A · Grid passthrough: 40 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-SG02LP2-US-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e7.6 kW split-phase hybrid inverter, the size between 6 kW and 8 kW\u003c\/h3\u003e\u003cp\u003eThe 7.6 kW and the 8 kW are close relatives: both charge at 190 A, both pass 50 A of grid current through to the loads and both accept 26 A per tracker. What separates them is output, 7,600 VA and 31.7 A per leg here against 8,000 VA and 33.4 A, and array size, 11,400 W against 12,000 W. Full load tracking drops to a 200 V floor on both.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 190 A · Max PV input power: 11,400 W · Max AC output current: 31.7 A · Grid passthrough: 50 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-7.6K-SG02LP2-US-AM2\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW split-phase hybrid inverter for a large home or a small business\u003c\/h3\u003e\u003cp\u003eThe largest of the four, and the one to pick if the roof is already drawn. It takes 12,000 W of panels and gives 8,000 VA at 33.4 A per leg, charging the battery at 190 A with 50 A of grid passthrough. Because it shares the charger and the 200 to 425 V full load window with the 7.6 kW, what you actually gain is 400 VA of output and 600 W of array.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eMax battery charge current: 190 A · Max PV input power: 12,000 W · Max AC output current: 33.4 A · Grid passthrough: 50 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-SG02LP2-US-AM2\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 4 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e120\/240V; 208V 0.88Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e60Hz\/55Hz-65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e125-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLead-acid or Lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e40-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e2L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Hz)\u003c\/td\u003e\n\u003ctd\u003e60Hz\/55Hz-65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power (W)\u003c\/td\u003e\n\u003ctd\u003e2 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS232, RS485, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEEE 1547.1,SRD V2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC IV(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eFCC,UL 1741\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e96.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e120\/240V, 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-40 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e35.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e420 x 670 x 233\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e2L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"5 kW","offer_id":47869741432937,"sku":"SUN-5K-SG02LP2-US-AM2","price":4400.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47869741465705,"sku":"SUN-6K-SG02LP2-US-AM2","price":4400.0,"currency_code":"AED","in_stock":true},{"title":"7.6 kW","offer_id":47869741498473,"sku":"SUN-7.6K-SG02LP2-US-AM2","price":4400.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869741531241,"sku":"SUN-8K-SG02LP2-US-AM2","price":4400.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-5-8K-SG02LP2-US.png?v=1785851399"},{"product_id":"deye-sun-g01p3-eu-am8-lv","title":"Deye 60–75 kW Three-Phase Low-Voltage Solar Inverter","description":"\u003cp\u003eMost commercial three-phase inverters expect a 380 V or 400 V grid. This low-voltage three-phase solar inverter is built for the networks that run at 127\/220 V or 133\/230 V instead, which covers Brazil and much of Latin America. Three ratings, 60 kW, 70 kW and 75 kW, share one 103 kg body, eight tracker inputs and a 200 V to 700 V tracking window.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutput at 127\/220 V or 133\/230 V, certified to NBR 16149, NBR 16150 and EN 50549.\u003c\/li\u003e\n\u003cli\u003eEight tracker inputs taking 40 A each, with an 800 V ceiling on the panel strings.\u003c\/li\u003e\n\u003cli\u003e98.2% European efficiency and better than 99% tracking efficiency on all three ratings.\u003c\/li\u003e\n\u003cli\u003eRuns at 55 dB or below, sealed to IP65, and rated to 60°C ambient and 4,000 m altitude.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e60 kW low-voltage inverter for a 90 kW array on a 220 V grid\u003c\/h3\u003e\u003cp\u003eThe 60 kW has the widest tracking window of the three: it holds full output from 290 V upward, against 330 V on the 70 kW and 360 V on the 75 kW. Shorter strings still make full power, which helps on a broken-up roof with several small planes. Output is 157.5 A per phase at 60 kVA, and the array can reach 90 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 60 kW · Full-load tracking window: 290 to 700 V · Max AC output current: 157.5 A · Max PV input: 90 kW\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-60K-G01P3-EU-AM8-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e70 kW three-phase low-voltage inverter for 105 kW of solar panels\u003c\/h3\u003e\u003cp\u003eThe 70 kW sits in the middle of the family: 183.8 A per phase, 70 kVA of apparent power, and up to 105 kW of panels. Full output needs at least 330 V from the string, so plan longer strings than the 60 kW model would need. Maximum output fault current is 351 A, and that is the number the protection device on the AC side has to clear.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 70 kW · Full-load tracking window: 330 to 700 V · Max AC output current: 183.8 A · Max output fault current: 351 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-70K-G01P3-EU-AM8-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e75 kW low-voltage inverter, the largest in the 127\/220 V range\u003c\/h3\u003e\u003cp\u003eThe 75 kW is the top rating here, at 196.9 A per phase and 75 kVA. It takes 112.5 kW of panels, 22.5 kW more than the 60 kW model inside the same enclosure, which is the simplest way to add array on a site short of wall space. It needs 360 V or more from each string to hold full output, the narrowest window of the three, so plan the string lengths carefully.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC output: 75 kW · Full-load tracking window: 360 to 700 V · Max AC output current: 196.9 A · Max PV input: 112.5 kW\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-75K-G01P3-EU-AM8-LV\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 3 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Voltage Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Short Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFCI Protection\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Over Current Protection (A)\u003c\/td\u003e\n\u003ctd\u003e398\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e8\/4+4+4+4+4+4+4+4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNBR 16149, NBR 16150, EN 50549, RD 140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e1006 x 516 x 325.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eDC Injection Current: \u0026lt;0.5%ln\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"60 kW","offer_id":47869741564009,"sku":"SUN-60K-G01P3-EU-AM8-LV","price":22500.0,"currency_code":"AED","in_stock":true},{"title":"70 kW","offer_id":47869741596777,"sku":"SUN-70K-G01P3-EU-AM8-LV","price":22500.0,"currency_code":"AED","in_stock":true},{"title":"75 kW","offer_id":47869741629545,"sku":"SUN-75K-G01P3-EU-AM8-LV","price":22500.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-60-75K-G01P3-LV.png?v=1785851401"},{"product_id":"deye-sun-g04p3-eu-am4","title":"Deye 60–80 kW Three-Phase Solar Inverter","description":"\u003cp\u003eA three-phase solar inverter of this size goes on the wall of a factory, a cold store or a school and sends the whole roof straight into the building's own supply. Four ratings share one 53.7 kg cabinet, so the frame, the cabling method and the spares stay the same whichever one is specified. Panels connect at up to 1,100 V, which keeps string counts and cable runs down on a large roof.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOne 53.7 kg cabinet across all four ratings, IP65 sealed and fan cooled at 55 dB or less\u003c\/li\u003e\n\u003cli\u003ePanel input to 1,100 V with tracking from 200 V, so long strings are allowed\u003c\/li\u003e\n\u003cli\u003eRated to 4,000 m altitude and ambient temperatures of -25 to 60 degrees C\u003c\/li\u003e\n\u003cli\u003eThree-phase 220\/380 V or 230\/400 V connection, wired 3L\/N\/PE\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e60 kW three-phase inverter for a mid-size commercial roof\u003c\/h3\u003e\u003cp\u003eThe smallest of the four, rated 60,000 W with 66,000 VA available and 90.9 A per phase. Its efficiency sits a shade below its siblings, at 98.6% peak and 98.0% European weighted. It holds full output from 490 V upward on the tracker, the widest window in the group, which leaves the string designer the most room. Panel input is capped at 90,000 W, half as much again as the AC rating.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 60,000 W · Max efficiency: 98.6% · Max PV input: 90,000 W · Full-load tracker window: 490-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-60K-G04P3-EU-AM4\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e70 kW three-phase inverter carrying 105 kW of panels on one unit\u003c\/h3\u003e\u003cp\u003eRated 70,000 W and 77,000 VA, giving 106.1 A per phase, with peak efficiency of 98.7% and 98.1% European weighted. Full output needs 570 V or more on the tracker. Panel input is capped at 105,000 W. Case, weight and altitude rating match the 60 kW exactly, so a site laid out for one takes the other with no change to the mounting or the cable entry.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 70,000 W · Max PV input: 105,000 W · Rated output current: 106.1 A · Full-load tracker window: 570-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-70K-G04P3-EU-AM4\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e75 kW three-phase inverter built around a 720 V string design\u003c\/h3\u003e\u003cp\u003eRated 75,000 W with 82,500 VA and 113.6 A per phase. This is the first of the four sized around a 720 V nominal panel voltage rather than 600 V, and it wants at least 610 V on the tracker to hold full output, so the strings are designed longer. Panel input is capped at 112,500 W. Peak efficiency is 98.7%, European weighted 98.1%.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 75,000 W · Nominal PV voltage: 720 V · Max PV input: 112,500 W · Full-load tracker window: 610-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-75K-G04P3-EU-AM4\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e80 kW three-phase inverter, the largest here at 120 kW of panels\u003c\/h3\u003e\u003cp\u003eThe biggest of the family at 80,000 W, 88,000 VA and 133.3 A per phase, and that current figure is the one to check against the incoming breaker and cable before ordering. Panels can total 120,000 W. Full output needs 650 V or more on the tracker, the narrowest window of the four. Efficiency is 98.7% peak and 98.1% European weighted, in the same 53.7 kg case.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated output: 80,000 W · Max AC output current: 133.3 A · Max PV input: 120,000 W · Full-load tracker window: 650-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-80K-G04P3-EU-AM4\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 4 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e53.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e698 x 613 x 236.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"60 kW","offer_id":47869741662313,"sku":"SUN-60K-G04P3-EU-AM4","price":24000.0,"currency_code":"AED","in_stock":true},{"title":"70 kW","offer_id":47869741695081,"sku":"SUN-70K-G04P3-EU-AM4","price":24000.0,"currency_code":"AED","in_stock":true},{"title":"75 kW","offer_id":47869741727849,"sku":"SUN-75K-G04P3-EU-AM4","price":24000.0,"currency_code":"AED","in_stock":true},{"title":"80 kW","offer_id":47869741760617,"sku":"SUN-80K-G04P3-EU-AM4","price":24000.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-60-80K-G04P3.png?v=1785851403"},{"product_id":"deye-sun-sg02hp3-eu-em6","title":"Deye 60–80 kW Three-Phase High-Voltage Hybrid Solar Inverter","description":"\u003cp\u003eThe SUN SG02HP3 is Deye's largest three-phase hybrid inverter, built for a factory, a cold store or a hotel that wants to run on solar by day and stored power into the evening. All four ratings take high-voltage lithium batteries between 160 V and 1000 V across two separate battery inputs, and any of them will pass 200 A of grid supply straight through to the loads. What separates them is how much panel they will accept and how much current they can push back out.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo battery inputs, each charging and discharging at up to 80 A, so storage can be added in two banks rather than one\u003c\/li\u003e\n\u003cli\u003eSix MPPT trackers per unit and up to 10 units in parallel, enough scope for a roof broken into several sections\u003c\/li\u003e\n\u003cli\u003e200 A of grid supply passes straight through to the loads, and the whole rating can sit on one phase if the site is unbalanced\u003c\/li\u003e\n\u003cli\u003eThe same 105 kg cabinet on every rating, IP65 sealed and rated from -40°C to 60°C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e60 kW three-phase hybrid inverter for a factory on 120 kW of panels\u003c\/h3\u003e\u003cp\u003eThe entry point of the range, and the one that copes best with a low-voltage array: it holds full output from 365 V upward, where the 80 kW wants 485 V. You can wire 120 kW of panels to it, of which 96 kW converts at any one moment, which leaves room for east and west pitches on a single machine. Rated output is 91 A per phase, peaking at 100 A and 66 kVA.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels connectable: 120 kW · Usable PV input: 96 kW · Rated current per phase: 91 A · Full-output PV window: 365-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-60K-SG02HP3-EU-EM6\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e70 kW three-phase hybrid solar inverter with 112 kW of usable PV\u003c\/h3\u003e\u003cp\u003eA 70 kW rating for sites whose supply agreement lands between the 60 and 75 kW models. It accepts 140 kW of panels with 112 kW usable at once, and delivers 106.1 A per phase, climbing to 116.7 A and 77 kVA at the ceiling. The array has to reach 425 V before it will hold full output, so strings run a little longer than they would on the 60 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels connectable: 140 kW · Usable PV input: 112 kW · Rated current per phase: 106.1 A · Full-output PV window: 425-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-70K-SG02HP3-EU-EM6\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e75 kW three-phase hybrid inverter for a large commercial rooftop\u003c\/h3\u003e\u003cp\u003eThis sits between the 70 and 80 kW models and is the usual pick when a 150 kW array is already on the roof, since 120 kW of that reaches the inverter at any one time. Output runs at 113.7 A per phase and rises to 125 A, with 82.5 kVA of apparent power for motor starting and similar surges. Full output begins once the strings clear 455 V.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels connectable: 150 kW · Usable PV input: 120 kW · Rated current per phase: 113.7 A · Full-output PV window: 455-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-75K-SG02HP3-EU-EM6\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e80 kW three-phase hybrid inverter, the biggest in the SG02HP3 line\u003c\/h3\u003e\u003cp\u003eThe largest of the four accepts 160 kW of panels with 128 kW converted at once, and pushes 121.3 A per phase, peaking at 133.4 A and 88 kVA. It also asks the most of the array, holding rated output only from 485 V upward, so strings need to be long enough to stay above that on a dull morning. Ten of these in parallel bring a site to 800 kW.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels connectable: 160 kW · Usable PV input: 128 kW · Rated current per phase: 121.3 A · Full-output PV window: 485-850 V\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-80K-SG02HP3-EU-EM6\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 4 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charge Current (A)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charge Discharge Current (A)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e160-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\/CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e150-850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Passthrough (A)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Discharge Current (A)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e220\/380V, 230\/400V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Units\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalanced Output (%)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Input Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e180-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Fault Current (A)\u003c\/td\u003e\n\u003ctd\u003e256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Ocp (A)\u003c\/td\u003e\n\u003ctd\u003e334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Reverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-40 to +60℃, \u0026gt;45℃ Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e606 x 927 x 314\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eCharging Strategy for Li-ion Battery: Self-adaption to BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"60 kW","offer_id":47869741793385,"sku":"SUN-60K-SG02HP3-EU-EM6","price":44000.0,"currency_code":"AED","in_stock":true},{"title":"70 kW","offer_id":47869741826153,"sku":"SUN-70K-SG02HP3-EU-EM6","price":44000.0,"currency_code":"AED","in_stock":true},{"title":"75 kW","offer_id":47869741858921,"sku":"SUN-75K-SG02HP3-EU-EM6","price":44000.0,"currency_code":"AED","in_stock":true},{"title":"80 kW","offer_id":47869741891689,"sku":"SUN-80K-SG02HP3-EU-EM6","price":44000.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-60-80K-SG02HP3.png?v=1785851405"},{"product_id":"deye-sun-g06-lv-p3","title":"Deye 6–8 kW Three-Phase Low-Voltage Solar Inverter","description":"\u003cp\u003eThe 6 kW and 8 kW models here are three-phase solar inverters made for low-voltage grids running at 127\/220 V or 133\/230 V. Both are 11 kg wall units with two MPPT trackers and no fan, which makes them practical over a shop counter or in a small workshop where nobody wants a noisy box overhead. The difference between the two is mainly how much panel each one will swallow.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBoth weigh 11 kg in a 283 x 463 x 178 mm case, so the same pair of bolts holds either one.\u003c\/li\u003e\n\u003cli\u003eTwo MPPT trackers with a 200 to 700 V window and a 300 to 700 V full-load band.\u003c\/li\u003e\n\u003cli\u003eWakes at 250 V and accepts up to 800 V from the array.\u003c\/li\u003e\n\u003cli\u003eIP65 sealed with natural cooling, meaning no fan to clog with dust.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e6 kW three-phase solar inverter for a 7.8 kW shop or villa array\u003c\/h3\u003e\u003cp\u003eRated 6 kW with 7,800 W of panel capacity and 15.8 A per phase. Both of its trackers take 20 A, so the array wants splitting fairly evenly between them. European weighted efficiency is 97.8% and maximum output fault current is 30.2 A. Pick this one when the roof is a single clean plane and the load is lighting, fans and a couple of small motors.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 6 kW · Max PV input power: 7,800 W · Max AC output current: 15.8 A · European efficiency: 97.8%\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-6K-G06-LV\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e8 kW three-phase solar inverter with 20 A and 26 A MPPT inputs\u003c\/h3\u003e\u003cp\u003eRated 8 kW and taking 10,400 W of panels, with 21 A per phase. Its two trackers are deliberately unequal, 20 A on one and 26 A on the other, which lets you hang a longer string on the bigger input instead of splitting the roof down the middle. European weighted efficiency is 98%, a little ahead of the 6 kW model, and maximum output fault current is 40.2 A.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated AC power: 8 kW · Max PV input power: 10,400 W · Max AC output current: 21 A · Max PV input current: 20 A + 26 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-8K-G06-LV\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 2 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Ocp (A)\u003c\/td\u003e\n\u003ctd\u003e47.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Full Load Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e300-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNBR 16149, NBR 16150, EN 50549, RD 140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC),OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading-0.8lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V 0.85Un-1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC),TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eNatural cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to +60℃,\u0026gt;45℃ derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e283 x 463 x 178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"6 kW","offer_id":47869741924457,"sku":"DEYE-SUN-6K-G06-LV","price":2800.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47869741957225,"sku":"DEYE-SUN-8K-G06-LV","price":2800.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-6-8K-G06-LV.png?v=1785851408"},{"product_id":"deye-sun-mg4","title":"Deye 300–2250 W Micro-Inverter","description":"\u003cp\u003eA micro-inverter sits under the panel and turns its output into mains power right there, so one shaded module cannot drag down the rest of the roof. Deye's G4 micro-inverter line runs from 300 W up to 2250 W, covering a single balcony panel through to a four-panel commercial string. Every unit is sealed to IP67, carries a 10-year warranty and reports over built-in Wi-Fi.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e96.5% peak conversion and 96% on the European weighted average, identical on every rating\u003c\/li\u003e\n\u003cli\u003eSealed to IP67 and rated from -40 to +65 C, which is what lets it live under the panel\u003c\/li\u003e\n\u003cli\u003e10-year warranty against a 25-year design life, and under 25 dB in operation\u003c\/li\u003e\n\u003cli\u003eEach panel input accepts up to 60 V and starts producing from 20 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e300 W micro-inverter for one panel, 17 units on a single branch\u003c\/h3\u003e\u003cp\u003eThe smallest unit in the line, for one panel rated between 210 W and 420 W. Because it draws so little current, 17 of them share a single branch circuit, which makes it the cheapest way to wire a long row of small modules. AC output is 1.4 A. The whole thing weighs 1.85 kg and measures 173 by 158.5 by 31.5 mm, small enough to clamp to the panel rail out of sight.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels per unit: 1 · Panel size accepted: 210 to 420 W · Units per branch: 17 · Max AC output: 1.4 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-M30G4-EU-Q0-I\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e400 W micro-inverter for a single panel rated up to 560 W\u003c\/h3\u003e\u003cp\u003eOne panel again, but the input window widens to 560 W, which covers most ordinary residential modules on sale today. Output rises to 1.9 A and branch capacity drops to 13 units, since each one draws more current. It uses the same 1.85 kg housing and the same single tracker as the 300 W. This is the right pick when the roof carries standard 400 W to 550 W panels and you want one micro per panel.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels per unit: 1 · Panel size accepted: 210 to 560 W · Units per branch: 13 · Max AC output: 1.9 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-M40G4-EU-Q0-I\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e500 W micro-inverter for one 700 W panel, ten per branch circuit\u003c\/h3\u003e\u003cp\u003eThe largest of the single-panel units, taking modules from 210 W all the way to 700 W. Output is 2.3 A and ten units fit on one branch. It shares the 1.85 kg case with the 300 W and 400 W, so nothing about mounting or clamping changes. Worth choosing over the 400 W only if the modules genuinely exceed 560 W, because the extra headroom costs you branch capacity.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels per unit: 1 · Panel size accepted: 210 to 700 W · Units per branch: 10 · Max AC output: 2.3 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-M50G4-EU-Q0-I\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e600 W micro-inverter for two panels, one balcony or small roof\u003c\/h3\u003e\u003cp\u003eFirst model to serve two panels, with a separate tracker for each, so a module in shade does not pull its neighbour down with it. Each input takes 210 W to 420 W. Output is 2.8 A, eight units fit per branch, and the housing grows to 3 kg at 280.5 by 190 by 40 mm. Two panels per unit halves the number of micros and AC connectors on a roof.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels per unit: 2 · Panel size accepted: 210 to 420 W each · Units per branch: 8 · Max AC output: 2.8 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-M60G4-EU-Q0\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e800 W micro-inverter for two panels of up to 560 W each, six per branch\u003c\/h3\u003e\u003cp\u003eTwo panels, two trackers, and an input window that stretches to 560 W per module, which suits a pair of standard residential panels. It gives 3.7 A of AC output and six units fit on one branch. Weight is 3 kg, the same body as the 600 W and 1000 W. For a balcony or a shed array built from two modern modules, this is usually the size that fits.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels per unit: 2 · Panel size accepted: 210 to 560 W each · Units per branch: 6 · Max AC output: 3.7 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-M80G4-EU-Q0\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e1000 W micro-inverter for two 700 W panels, five units per branch\u003c\/h3\u003e\u003cp\u003eTwo panels of up to 700 W each, the top of the twin-input group. Output reaches 4.6 A and five units share a branch. It uses the same 3 kg body as the 600 W and 800 W, so an installer can stock one bracket for all three sizes. Pick it when the modules are large-format 600 W or 700 W panels and you still want one micro for every two of them.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels per unit: 2 · Panel size accepted: 210 to 700 W each · Units per branch: 5 · Max AC output: 4.6 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-M100G4-EU-Q0\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e1300 W micro-inverter for four panels rated 210 to 460 W each\u003c\/h3\u003e\u003cp\u003eThe first four-panel unit, with four independent trackers in a 5.1 kg housing measuring 311 by 250.5 by 36.5 mm. Each input takes a module between 210 W and 460 W, the narrowest panel window in the four-input group. Output is 6 A and five units fit on a branch. Fewer boxes and fewer cable runs than four separate micros, at the cost of one shared enclosure.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels per unit: 4 · Panel size accepted: 210 to 460 W each · Units per branch: 5 · Max AC output: 6 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-M130G4-EU-Q0\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e1600 W micro-inverter for four panels of up to 560 W, four per branch\u003c\/h3\u003e\u003cp\u003eFour panels again, but each input now accepts up to 560 W, so it fits ordinary residential modules rather than the smaller ones the 1300 W is limited to. Output climbs to 7.3 A and branch capacity falls to four units. The 5.1 kg housing is unchanged. At full load its tracking window opens at 31.5 V, a little higher than the 1300 W, which only matters on very low-voltage modules.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels per unit: 4 · Panel size accepted: 210 to 560 W each · Units per branch: 4 · Max AC output: 7.3 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-M160G4-EU-Q0\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e1800 W micro-inverter for four panels rated up to 630 W each\u003c\/h3\u003e\u003cp\u003eFour inputs taking modules up to 630 W each, sitting between the 1600 W and the 2000 W. Output is 8.2 A and three units share a branch, as on every size above it. Weight stays at 5.1 kg in the same 311 by 250.5 mm housing. Its full-load tracking window opens at 33 V. This is the size to choose when the roof runs 550 W to 630 W panels in groups of four.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels per unit: 4 · Panel size accepted: 210 to 630 W each · Units per branch: 3 · Max AC output: 8.2 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-M180G4-EU-Q0\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e2000 W micro-inverter for four 700 W panels on a shared roof string\u003c\/h3\u003e\u003cp\u003eFour panels of up to 700 W each in the 5.1 kg housing, giving 9.1 A of AC output with three units per branch. Full-load tracking starts at 36.5 V, so the modules need a reasonable open-circuit voltage to hold rated output. On a commercial roof built from 650 W or 700 W modules this handles four of them per box and keeps the AC connector count down.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels per unit: 4 · Panel size accepted: 210 to 700 W each · Units per branch: 3 · Max AC output: 9.1 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-M200G4-EU-Q0\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e2200 W micro-inverter for four panels up to 770 W, 10 A AC output\u003c\/h3\u003e\u003cp\u003eA physically larger unit than the 1300 W through 2000 W: 358 by 255.5 by 36.5 mm and 5.2 kg. Each of the four inputs carries 18 A rather than 15 A and accepts modules up to 770 W. Output is 10 A with three units per branch. That higher input current is the real difference here, because it is what allows the bigger modules rather than simply a higher AC rating.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels per unit: 4 · Panel size accepted: 210 to 770 W each · Units per branch: 3 · Max AC output: 10 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-M220G4-EU-Q0\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e2250 W micro-inverter, the largest here, for panels up to 790 W\u003c\/h3\u003e\u003cp\u003eThe largest micro-inverter in this range, and very close to the 2200 W. It shares the 5.2 kg body and the 18 A per-input rating, and differs in two figures: modules up to 790 W instead of 770 W, and 10.3 A of AC output instead of 10 A. Three units per branch either way. Unless your modules fall between 770 W and 790 W, the two are interchangeable in practice.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels per unit: 4 · Panel size accepted: 210 to 790 W each · Units per branch: 3 · Max AC output: 10.3 A\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-M225G4-EU-Q0\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 12 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e96.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003eL\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eIsolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e25-55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e42.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-40 to 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eL\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"300 W","offer_id":47869741989993,"sku":"SUN-M30G4-EU-Q0-I","price":279.0,"currency_code":"AED","in_stock":true},{"title":"400 W","offer_id":47869742022761,"sku":"SUN-M40G4-EU-Q0-I","price":279.0,"currency_code":"AED","in_stock":true},{"title":"500 W","offer_id":47869742055529,"sku":"SUN-M50G4-EU-Q0-I","price":279.0,"currency_code":"AED","in_stock":true},{"title":"600 W","offer_id":47869742088297,"sku":"SUN-M60G4-EU-Q0","price":709.0,"currency_code":"AED","in_stock":true},{"title":"800 W","offer_id":47869742121065,"sku":"SUN-M80G4-EU-Q0","price":709.0,"currency_code":"AED","in_stock":true},{"title":"1000 W","offer_id":47869742153833,"sku":"SUN-M100G4-EU-Q0","price":709.0,"currency_code":"AED","in_stock":true},{"title":"1300 W","offer_id":47869742186601,"sku":"SUN-M130G4-EU-Q0","price":725.0,"currency_code":"AED","in_stock":true},{"title":"1600 W","offer_id":47869742219369,"sku":"SUN-M160G4-EU-Q0","price":725.0,"currency_code":"AED","in_stock":true},{"title":"1800 W","offer_id":47869742252137,"sku":"SUN-M180G4-EU-Q0","price":725.0,"currency_code":"AED","in_stock":true},{"title":"2000 W","offer_id":47869742284905,"sku":"SUN-M200G4-EU-Q0","price":725.0,"currency_code":"AED","in_stock":true},{"title":"2200 W","offer_id":47869742317673,"sku":"SUN-M220G4-EU-Q0","price":725.0,"currency_code":"AED","in_stock":true},{"title":"2250 W","offer_id":47869742350441,"sku":"DEYE-SUN-M225G4-EU-Q0","price":668.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-M130-220G4.png?v=1785851411"},{"product_id":"sun-23-30k-g04-lv","title":"Deye 23–30 kW Three-Phase Low-Voltage Solar Inverter","description":"\u003cp\u003e\u003cstrong\u003e23-30 kW low-voltage three-phase inverter for a workshop or farm\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA three-phase low-voltage solar inverter built for grids that run at 127\/220 V or 133\/230 V rather than the 230\/400 V used in Europe and the Gulf, which is what the LV in the name refers to. It suits a workshop, a farm or a small commercial building of roughly 23 kW to 30 kW, feeding the building first and the grid after. Fitting a standard 400 V model to one of these supplies does not work, which is the reason this version exists.\u003c\/p\u003e\u003cp\u003eOne machine covering the 23 kW to 30 kW band on a 127\/220 V three-phase supply. Panels can reach 800 V, tracking runs from 200 V to 700 V and it needs 250 V on the strings before it starts producing. It weighs 37.1 kg in a 434 x 570 x 243 mm case and cools with a fan, so it sits at about 65 dB, better placed on a plant room wall than beside an office window. Five-year warranty.\u003c\/p\u003e\u003ch2\u003eAt a glance\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power band\u003c\/td\u003e\n\u003ctd\u003e23-30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV input voltage\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT window\u003c\/td\u003e\n\u003ctd\u003e200-700 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e37.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power (W)\u003c\/td\u003e\n\u003ctd\u003e30000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eString Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V 0.85UN-1.1UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current (A)\u003c\/td\u003e\n\u003ctd\u003e78.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e4\/3+3+3+3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Power (W)\u003c\/td\u003e\n\u003ctd\u003e39000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Apparent Power (VA)\u003c\/td\u003e\n\u003ctd\u003e30000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Full Load Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e250-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNBR 16149, NBR 16150, EN 50549, RD 140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD1602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e98.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inverter Backfeed Current (A)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eGPRS\/WIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/45-55, 60\/55-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e127V\/220V, 133V\/230V 0.85UN-1.1UN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Nominal Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II(DC), TYPE II(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e37.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25 to +60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e434 x 570 x 243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cp\u003e\u003csmall\u003eModel code: SUN-23-30K-G04-LV\u003c\/small\u003e\u003c\/p\u003e","brand":"DEYE","offers":[{"title":"Default Title","offer_id":47869742383209,"sku":"DEYE-SUN-23-30K-G04-LV","price":10500.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/SUN-23-30K-G04-LV.png?v=1785851412"},{"product_id":"felicity-solar-ai100","title":"Felicity Solar 5–8 kW All-in-One Home Energy Storage System","description":"\u003cp\u003e\u003cstrong\u003eFelicity Solar 5–8 kW All-in-One Home Energy Storage System\u003c\/strong\u003e, available in 2 ratings, 5 kW to 8 kW. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eKeeps 93% of what the panels make\u003c\/li\u003e\n\u003cli\u003eCertified to IP20\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e5 kW\u003c\/h3\u003e\u003cp\u003eModel AI100-5048-ESS. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e8 kW\u003c\/h3\u003e\u003cp\u003eModel AI100-8048. Full specifications are listed below.\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 2 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Open Circuit Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e230Vac±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e90V-450V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Mode Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e5%~95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"Felicity Solar","offers":[{"title":"5 kW","offer_id":47922333319273,"sku":"AI100-5048-ESS","price":2386.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47922333352041,"sku":"AI100-8048","price":4500.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ai100_5048.jpg?v=1787208728"},{"product_id":"felicity-solar-ivbm-p1g1","title":"Felicity Solar 8–10 kVA Single-Phase Hybrid Solar Inverter","description":"\u003cp\u003e\u003cstrong\u003eFelicity Solar 8–10 kVA Single-Phase Hybrid Solar Inverter\u003c\/strong\u003e, available in 2 ratings, 8 kVA to 10 kVA. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eKeeps 94.5% of what the panels make\u003c\/li\u003e\n\u003cli\u003e2 Years manufacturer warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e8 kVA\u003c\/h3\u003e\u003cp\u003eModel IVBM8048P1G1. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e10 kVA\u003c\/h3\u003e\u003cp\u003eModel IVBM10048P1G1. Full specifications are listed below.\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 2 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Start Capable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e94.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Line Disconnect (V)\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e90~280Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Line Disconnect (V)\u003c\/td\u003e\n\u003ctd\u003e170Vac±7V (UPS); 90Vac±7V (appliances)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Open Circuit Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e230Vac±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e5s@≥150% load; 10s@105%~150% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50±0.3Hz\/60Hz±0.3Hz (Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Mode Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e230Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Line Reconnect (V)\u003c\/td\u003e\n\u003ctd\u003e180Vac±7V (UPS); 100Vac±7V (appliances)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Line Reconnect (V)\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Freq Disconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Freq Reconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Freq Disconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Freq Reconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Mode Output Waveform\u003c\/td\u003e\n\u003ctd\u003eAs same as input waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Power (VA)\u003c\/td\u003e\n\u003ctd\u003e2* rated power for 5s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Battery Recovery Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e47.0V (load \u0026lt; 50%) \/ 46.0V (load ≥ 50%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e43.0V (load \u0026lt; 50%) \/ 42.0V (load ≥ 50%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e597x572x267mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight (kg)\u003c\/td\u003e\n\u003ctd\u003e28.3kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e490 x 189.2 x 525\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e0°C~50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range (°C)\u003c\/td\u003e\n\u003ctd\u003e-15°C~60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e28.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003ePass Through Without Battery: Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"Felicity Solar","offers":[{"title":"8 kVA","offer_id":47922335481961,"sku":"IVBM8048P1G1","price":5500.0,"currency_code":"AED","in_stock":true},{"title":"10 kVA","offer_id":47922335514729,"sku":"IVBM10048P1G1","price":5500.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivbm_8_10kw.jpg?v=1787208780"},{"product_id":"felicity-solar-ivcm-p1g2","title":"Felicity Solar 2–3.2 kVA Single-Phase Off-Grid Solar Inverter","description":"\u003cp\u003e\u003cstrong\u003eFelicity Solar 2–3.2 kVA Single-Phase Off-Grid Solar Inverter\u003c\/strong\u003e, available in 2 ratings, 2 kVA \/ 12 V to 3.2 kVA \/ 24 V. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e2 Years manufacturer warranty\u003c\/li\u003e\n\u003cli\u003eCertified to CE, ISO9001\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e2 kVA \/ 12 V\u003c\/h3\u003e\u003cp\u003eModel IVCM2012P1G2. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e3.2 kVA \/ 24 V\u003c\/h3\u003e\u003cp\u003eModel IVCM3224P1G2. Full specifications are listed below.\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 2 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e90-280Vac Surge Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSinusoidal (utility or generator)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\/ 60HZ Self - defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercharge Protection\u003c\/td\u003e\n\u003ctd\u003eYes Low Battery Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e230Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50±0.3Hz\/60±0.3Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Open Circuit Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e438x358x202mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kg)\u003c\/td\u003e\n\u003ctd\u003e6.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e356 x 128 x 276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-10°C-55°С\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range (°C)\u003c\/td\u003e\n\u003ctd\u003e-15°C -60°С\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e6.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"Felicity Solar","offers":[{"title":"2 kVA \/ 12 V","offer_id":47922335580265,"sku":"IVCM2012P1G2","price":1600.0,"currency_code":"AED","in_stock":true},{"title":"3.2 kVA \/ 24 V","offer_id":47922335613033,"sku":"IVCM3224P1G2","price":1600.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivcm2_3kw_p1g2.jpg?v=1787208782"},{"product_id":"felicity-solar-ivem-lv","title":"Felicity Solar 3–5 kVA 110 V Single-Phase Off-Grid Solar Inverter","description":"\u003cp\u003e\u003cstrong\u003eFelicity Solar 3–5 kVA 110 V Single-Phase Off-Grid Solar Inverter\u003c\/strong\u003e, available in 2 ratings, 3 kVA to 5 kVA. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eKeeps 93% of what the panels make\u003c\/li\u003e\n\u003cli\u003e2 Years manufacturer warranty\u003c\/li\u003e\n\u003cli\u003eCertified to CE, ISO9001\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3 kVA\u003c\/h3\u003e\u003cp\u003eModel IVEM3048-LV. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e5 kVA\u003c\/h3\u003e\u003cp\u003eModel IVEM5048-LV. Full specifications are listed below.\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 2 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Start Capable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e90-280Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Operating Current (A)\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Open Circuit Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50±0.3Hz\/60Hz±0.3Hz(Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSinusoidal (utility or generator)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e110Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Line Disconnect (V)\u003c\/td\u003e\n\u003ctd\u003e65Vac±3V (home appliances) \/ 90Vac±3V (computers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Line Reconnect (V)\u003c\/td\u003e\n\u003ctd\u003e70Vac±3V (home appliances) \/ 95Vac±3V (computers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Line Disconnect (V)\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Line Reconnect (V)\u003c\/td\u003e\n\u003ctd\u003e135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz (auto detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Freq Disconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Freq Reconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Freq Disconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Freq Reconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Mode Output Waveform\u003c\/td\u003e\n\u003ctd\u003eSame as input waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eLine mode: circuit breaker; battery mode: electronic circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time Ms\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercharge Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e90V-500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Startup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoost Charge Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e56.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloating Charge Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charging Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLithium Charging Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e110Vac±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e5.5s@≥150% load; 10.5s@105%~150% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Battery Recovery Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e47.0V (load \u0026lt; 50%) \/ 46.0V (load ≥ 50%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e43.0V (load \u0026lt; 50%) \/ 42.0V (load ≥ 50%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range (°C)\u003c\/td\u003e\n\u003ctd\u003e-15°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"Felicity Solar","offers":[{"title":"3 kVA","offer_id":47922335678569,"sku":"IVEM3048-LV","price":1321.0,"currency_code":"AED","in_stock":true},{"title":"5 kVA","offer_id":47922335711337,"sku":"IVEM5048-LV","price":1321.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivem5048_lv.jpg?v=1787208785"},{"product_id":"felicity-solar-ivgm-lp3g1","title":"Felicity Solar 10–20 kW Three-Phase Low-Voltage Hybrid Solar Inverter","description":"\u003cp\u003e\u003cstrong\u003eFelicity Solar 10–20 kW Three-Phase Low-Voltage Hybrid Solar Inverter\u003c\/strong\u003e, available in 7 ratings, 10 kW to 20 kW. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSealed against dust and rain (IP65), so it can live outdoors\u003c\/li\u003e\n\u003cli\u003e2 independent trackers, so panels on different roof faces do not drag each other down\u003c\/li\u003e\n\u003cli\u003e2 Years manufacturer warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e10 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM10KLP3G1. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e12 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM12KLP3G1. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e14 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM14KLP3G1. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e15 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM15KLP3G1. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e16 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM16KLP3G1. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e18 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM18KLP3G1. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e20 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM20KLP3G1. Full specifications are listed below.\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 7 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e160-650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT And Strings\u003c\/td\u003e\n\u003ctd\u003e2\/2+2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLi-Ion \/ Lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e40-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003e2 Times of Rated Power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Reverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Voltage Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Short Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Temperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Component Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Switch\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eTYPE II (DC), TYPE II (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMS Communication\u003c\/td\u003e\n\u003ctd\u003eRS485\/CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eWiFi\/4G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kg)\u003c\/td\u003e\n\u003ctd\u003e48.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight (kg)\u003c\/td\u003e\n\u003ctd\u003e60.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e750 x 450 x 268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e889 x 566 x 397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB\/T 34120, GB\/T 34133, GB\/T 34129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty (years)\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e60.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"Felicity Solar","offers":[{"title":"10 kW","offer_id":47922335744105,"sku":"IVGM10KLP3G1","price":5500.0,"currency_code":"AED","in_stock":true},{"title":"12 kW","offer_id":47922335776873,"sku":"IVGM12KLP3G1","price":6600.0,"currency_code":"AED","in_stock":true},{"title":"14 kW","offer_id":47922335809641,"sku":"IVGM14KLP3G1","price":7700.0,"currency_code":"AED","in_stock":true},{"title":"15 kW","offer_id":47922335842409,"sku":"IVGM15KLP3G1","price":8250.0,"currency_code":"AED","in_stock":true},{"title":"16 kW","offer_id":47922335875177,"sku":"IVGM16KLP3G1","price":8800.0,"currency_code":"AED","in_stock":true},{"title":"18 kW","offer_id":47922335907945,"sku":"IVGM18KLP3G1","price":9900.0,"currency_code":"AED","in_stock":true},{"title":"20 kW","offer_id":47922335940713,"sku":"IVGM20KLP3G1","price":7409.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivgm10klp3g1.jpg?v=1787208789"},{"product_id":"felicity-solar-ivgm-hp3g2","title":"Felicity Solar 25–50 kW Three-Phase High-Voltage Hybrid Solar Inverter (IVGM-HP3G2)","description":"\u003cp\u003e\u003cstrong\u003eFelicity Solar 25–50 kW Three-Phase High-Voltage Hybrid Solar Inverter (IVGM-HP3G2)\u003c\/strong\u003e, available in 5 ratings, 25 kW to 50 kW. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eSealed against dust and rain (IP65), so it can live outdoors\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e25 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM25KHP3G2. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e29.9 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM29K9HP3G2. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e30 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM30KHP3G2. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e40 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM40KHP3G2. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e50 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM50KHP3G2. Full specifications are listed below.\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 5 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e160~800Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charge Current (A)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Discharge Current (A)\u003c\/td\u003e\n\u003ctd\u003e50+50(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Over Current Protection (A)\u003c\/td\u003e\n\u003ctd\u003e(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Duration\u003c\/td\u003e\n\u003ctd\u003epower, 10S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eWiFi\/GPRS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMS Communication\u003c\/td\u003e\n\u003ctd\u003eRS485,CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin DC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eSmart Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e107.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eDC Injection Current: \u0026lt;0.5% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"Felicity Solar","offers":[{"title":"25 kW","offer_id":47922335973481,"sku":"IVGM25KHP3G2","price":9200.0,"currency_code":"AED","in_stock":true},{"title":"29.9 kW","offer_id":47922336006249,"sku":"IVGM29K9HP3G2","price":10950.0,"currency_code":"AED","in_stock":true},{"title":"30 kW","offer_id":47922336039017,"sku":"IVGM30KHP3G2","price":11000.0,"currency_code":"AED","in_stock":true},{"title":"40 kW","offer_id":47922336071785,"sku":"IVGM40KHP3G2","price":14700.0,"currency_code":"AED","in_stock":true},{"title":"50 kW","offer_id":47922336104553,"sku":"IVGM50KHP3G2","price":18350.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivgm50khp3g2.jpg?v=1787208793"},{"product_id":"felicity-solar-ivgm-lp2g1","title":"Felicity Solar 5–8 kW Split-Phase Low-Voltage Hybrid Solar Inverter","description":"\u003cp\u003e\u003cstrong\u003eFelicity Solar 5–8 kW Split-Phase Low-Voltage Hybrid Solar Inverter\u003c\/strong\u003e, available in 4 ratings, 5 kW to 8 kW. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSealed against dust and rain (IP65), so it can live outdoors\u003c\/li\u003e\n\u003cli\u003eKeeps 97.6% of what the panels make\u003c\/li\u003e\n\u003cli\u003e2 independent trackers, so panels on different roof faces do not drag each other down\u003c\/li\u003e\n\u003cli\u003eQuiet in use (35 dB)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e5 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM5KLP2G1. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e6 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM6KLP2G1. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e7.6 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM7K6LP2G1. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e8 kW\u003c\/h3\u003e\u003cp\u003eModel IVGM8KLP2G1. Full specifications are listed below.\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 4 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e40V~60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLi-Ion \/ Lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e90V~500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e120V~425V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e120\/240Vac (split phase), 208Vac (2 of 3 phase), 230Vac (single phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS232 \u0026amp; RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMS Communication\u003c\/td\u003e\n\u003ctd\u003eCAN \u0026amp; RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eWi-Fi \/ GPRS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD + LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kg)\u003c\/td\u003e\n\u003ctd\u003e33.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight (kg)\u003c\/td\u003e\n\u003ctd\u003e40.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e430 x 654 x 243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e787×547×358 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25°C~60°C, \u0026gt;45°C derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (%)\u003c\/td\u003e\n\u003ctd\u003e0~95% (No condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eSmart cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e40.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eCharging Strategy for Li-Ion Battery: Self-adaption to BMS; Displacement power factor: 0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"Felicity Solar","offers":[{"title":"5 kW","offer_id":47922336137321,"sku":"IVGM5KLP2G1","price":2300.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47922336170089,"sku":"IVGM6KLP2G1","price":2750.0,"currency_code":"AED","in_stock":true},{"title":"7.6 kW","offer_id":47922336202857,"sku":"IVGM7K6LP2G1","price":3490.0,"currency_code":"AED","in_stock":true},{"title":"8 kW","offer_id":47922336235625,"sku":"IVGM8KLP2G1","price":3670.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivgm10klp3g1_4260e56f-c428-43eb-aea1-21869a999d0a.jpg?v=1787208795"},{"product_id":"felicity-solar-ivpm","title":"Felicity Solar 5–10 kVA 48 V Off-Grid Solar Inverter (IVPM)","description":"\u003cp\u003e\u003cstrong\u003eFelicity Solar 5–10 kVA 48 V Off-Grid Solar Inverter (IVPM)\u003c\/strong\u003e, available in 3 ratings, 5 kVA to 10 kVA. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eKeeps 90% of what the panels make\u003c\/li\u003e\n\u003cli\u003e2 Years manufacturer warranty\u003c\/li\u003e\n\u003cli\u003eCertified to CE\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e5 kVA\u003c\/h3\u003e\u003cp\u003eModel IVPM5048. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e7.5 kVA\u003c\/h3\u003e\u003cp\u003eModel IVPM7548. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e10 kVA\u003c\/h3\u003e\u003cp\u003eModel IVPM10048. Full specifications are listed below.\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 3 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Passthrough (A)\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Power (W)\u003c\/td\u003e\n\u003ctd\u003e6600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Open Circuit Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Solar Charge Current (A)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50±0.3Hz\/60Hz±0.3Hz(Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercharge Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220Vac ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Regulation (%)\u003c\/td\u003e\n\u003ctd\u003e±5% rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Power (VA)\u003c\/td\u003e\n\u003ctd\u003e2× rated power for 5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e5s @ ≥150% load; 10s @ 105%~150% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time Ms\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e90~280 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eAGM, Flooded or Self-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLow-frequency (transformer-based)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e0°C ~ 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range (°C)\u003c\/td\u003e\n\u003ctd\u003e-15°C ~ 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc Note\u003c\/td\u003e\n\u003ctd\u003eMax Bypass Overload Current: AC 63A; Charger Short Circuit: AC 63A; Pass Through Without Battery: No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"Felicity Solar","offers":[{"title":"5 kVA","offer_id":47922336268393,"sku":"IVPM5048","price":2300.0,"currency_code":"AED","in_stock":true},{"title":"7.5 kVA","offer_id":47922336301161,"sku":"IVPM7548","price":3440.0,"currency_code":"AED","in_stock":true},{"title":"10 kVA","offer_id":47922336333929,"sku":"IVPM10048","price":4590.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivps5048.jpg?v=1787208798"},{"product_id":"felicity-solar-ivps-base","title":"Felicity Solar 2.5–10 kVA Off-Grid Solar Inverter","description":"\u003cp\u003e\u003cstrong\u003eFelicity Solar 2.5–10 kVA Off-Grid Solar Inverter\u003c\/strong\u003e, available in 7 ratings, 2.5 kVA \/ 12 V to 10 kVA \/ 48 V. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eKeeps 90% of what the panels make\u003c\/li\u003e\n\u003cli\u003e2 Years manufacturer warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e2.5 kVA \/ 12 V\u003c\/h3\u003e\u003cp\u003eModel IVPS2512. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e2.5 kVA \/ 24 V\u003c\/h3\u003e\u003cp\u003eModel IVPS2524. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e3.5 kVA \/ 24 V\u003c\/h3\u003e\u003cp\u003eModel IVPS3524. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e5 kVA \/ 24 V\u003c\/h3\u003e\u003cp\u003eModel IVPS5024. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e5 kVA \/ 48 V\u003c\/h3\u003e\u003cp\u003eModel IVPS5048. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e7.5 kVA \/ 48 V\u003c\/h3\u003e\u003cp\u003eModel IVPS7548. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e10 kVA \/ 48 V\u003c\/h3\u003e\u003cp\u003eModel IVPS10048. Full specifications are listed below.\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 7 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Start Capable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e90-280Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSinusoidal (utility or generator)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Line Disconnect (V)\u003c\/td\u003e\n\u003ctd\u003e170±7Vac (UPS) \/ 90±7Vac (APL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Line Reconnect (V)\u003c\/td\u003e\n\u003ctd\u003e180±7Vac (UPS) \/ 100±7Vac (APL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Line Disconnect (V)\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Line Reconnect (V)\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Freq Disconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Freq Reconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Freq Disconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Freq Reconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time Ms\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercharge Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e220Vac±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50±0.3Hz \/ 60±0.3Hz (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Regulation (%)\u003c\/td\u003e\n\u003ctd\u003e±5%rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"Felicity Solar","offers":[{"title":"2.5 kVA \/ 12 V","offer_id":47922336366697,"sku":"IVPS2512","price":600.0,"currency_code":"AED","in_stock":true},{"title":"2.5 kVA \/ 24 V","offer_id":47922336399465,"sku":"IVPS2524","price":600.0,"currency_code":"AED","in_stock":true},{"title":"3.5 kVA \/ 24 V","offer_id":47922336432233,"sku":"IVPS3524","price":840.0,"currency_code":"AED","in_stock":true},{"title":"5 kVA \/ 24 V","offer_id":47922336465001,"sku":"IVPS5024","price":1200.0,"currency_code":"AED","in_stock":true},{"title":"5 kVA \/ 48 V","offer_id":47922336497769,"sku":"IVPS5048","price":1321.0,"currency_code":"AED","in_stock":true},{"title":"7.5 kVA \/ 48 V","offer_id":47922336530537,"sku":"IVPS7548","price":1750.0,"currency_code":"AED","in_stock":true},{"title":"10 kVA \/ 48 V","offer_id":47922336563305,"sku":"IVPS10048","price":2500.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivps5024.jpg?v=1787208802"},{"product_id":"felicity-solar-ivps-p1g1-p2g1","title":"Felicity Solar 3.5–10 kVA Single-Phase Off-Grid Solar Inverter","description":"\u003cp\u003e\u003cstrong\u003eFelicity Solar 3.5–10 kVA Single-Phase Off-Grid Solar Inverter\u003c\/strong\u003e, available in 4 ratings, 3.5 kVA \/ 24 V to 10 kVA \/ 48 V. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eKeeps 90% of what the panels make\u003c\/li\u003e\n\u003cli\u003e2 Years manufacturer warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3.5 kVA \/ 24 V\u003c\/h3\u003e\u003cp\u003eModel IVPS3524P1G1-LV. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e5 kVA \/ 48 V\u003c\/h3\u003e\u003cp\u003eModel IVPS5048P1G1-LV. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e7.5 kVA \/ 48 V\u003c\/h3\u003e\u003cp\u003eModel IVPS7548P2G1. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e10 kVA \/ 48 V\u003c\/h3\u003e\u003cp\u003eModel IVPS10048P2G1. Full specifications are listed below.\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 4 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMS Communication\u003c\/td\u003e\n\u003ctd\u003e24V model(default 27.0V) bm5 6 bmS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Start Capable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Passthrough (A)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Derating\u003c\/td\u003e\n\u003ctd\u003e216-06 221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSinusoidal (utility or generator)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Freq Disconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Freq Reconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Freq Disconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Freq Reconnect (Hz)\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Mode Output Waveform\u003c\/td\u003e\n\u003ctd\u003eSynchronize with input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time Ms\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercharge Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Regulation (%)\u003c\/td\u003e\n\u003ctd\u003e±5%rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e0°C~40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range (°C)\u003c\/td\u003e\n\u003ctd\u003e-15°C~60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"Felicity Solar","offers":[{"title":"3.5 kVA \/ 24 V","offer_id":47922336596073,"sku":"IVPS3524P1G1-LV","price":1750.0,"currency_code":"AED","in_stock":true},{"title":"5 kVA \/ 48 V","offer_id":47922336628841,"sku":"IVPS5048P1G1-LV","price":1750.0,"currency_code":"AED","in_stock":true},{"title":"7.5 kVA \/ 48 V","offer_id":47922336661609,"sku":"IVPS7548P2G1","price":1750.0,"currency_code":"AED","in_stock":true},{"title":"10 kVA \/ 48 V","offer_id":47922336694377,"sku":"IVPS10048P2G1","price":1750.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivps3_5_10kva_us.jpg?v=1787208806"},{"product_id":"felicity-solar-t-rex-hp3g01","title":"Felicity Solar 25–50 kW Three-Phase High-Voltage Hybrid Solar Inverter","description":"\u003cp\u003e\u003cstrong\u003eFelicity Solar 25–50 kW Three-Phase High-Voltage Hybrid Solar Inverter\u003c\/strong\u003e, available in 5 ratings, 25 kW to 50 kW. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSealed against dust and rain (IP65), so it can live outdoors\u003c\/li\u003e\n\u003cli\u003eKeeps 97.6% of what the panels make\u003c\/li\u003e\n\u003cli\u003e2 Years manufacturer warranty\u003c\/li\u003e\n\u003cli\u003eCertified to CE, IEC 60947-1, IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e25 kW\u003c\/h3\u003e\u003cp\u003eModel T-REX-25KHP3G01. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e29.9 kW\u003c\/h3\u003e\u003cp\u003eModel T-REX-29K9HP3G01. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e30 kW\u003c\/h3\u003e\u003cp\u003eModel T-REX-30KHP3G01. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e40 kW\u003c\/h3\u003e\u003cp\u003eModel T-REX-40KHP3G01. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e50 kW\u003c\/h3\u003e\u003cp\u003eModel T-REX-50KHP3G01. Full specifications are listed below.\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 5 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e200-850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charge Current (A)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin DC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Grid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3W+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLightning Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Reverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Reverse Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Monitoring\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Monitoring\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Voltage Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eWiFi\/GPRS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight (kg)\u003c\/td\u003e\n\u003ctd\u003e102.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e940 x 582 x 340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e1114 x 774 x 469\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eSmart cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eNRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, G99\/1, CEI 0-21, NC.RFG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty (years)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e102.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"Felicity Solar","offers":[{"title":"25 kW","offer_id":47922337218665,"sku":"T-REX-25KHP3G01","price":13750.0,"currency_code":"AED","in_stock":true},{"title":"29.9 kW","offer_id":47922337251433,"sku":"T-REX-29K9HP3G01","price":13750.0,"currency_code":"AED","in_stock":true},{"title":"30 kW","offer_id":47922337284201,"sku":"T-REX-30KHP3G01","price":13750.0,"currency_code":"AED","in_stock":true},{"title":"40 kW","offer_id":47922337316969,"sku":"T-REX-40KHP3G01","price":13750.0,"currency_code":"AED","in_stock":true},{"title":"50 kW","offer_id":47922337349737,"sku":"T-REX-50KHP3G01","price":13750.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivgm2550kw_p3g1.jpg?v=1787208818"},{"product_id":"felicity-solar-t-rex-lp1g01","title":"Felicity Solar 3–6 kW Single-Phase Low-Voltage Hybrid Solar Inverter","description":"\u003cp\u003e\u003cstrong\u003eFelicity Solar 3–6 kW Single-Phase Low-Voltage Hybrid Solar Inverter\u003c\/strong\u003e, available in 6 ratings, 3 kW to 6 kW. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSealed against dust and rain (IP65), so it can live outdoors\u003c\/li\u003e\n\u003cli\u003e2 independent trackers, so panels on different roof faces do not drag each other down\u003c\/li\u003e\n\u003cli\u003e2 Years manufacturer warranty\u003c\/li\u003e\n\u003cli\u003eCertified to CE, EU WEEE\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e3 kW\u003c\/h3\u003e\u003cp\u003eModel T-REX-3KLP1G01. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e3.6 kW\u003c\/h3\u003e\u003cp\u003eModel T-REX-3K6LP1G01. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e4 kW\u003c\/h3\u003e\u003cp\u003eModel T-REX-4KLP1G01. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e4.6 kW\u003c\/h3\u003e\u003cp\u003eModel T-REX-4K6LP1G01. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e5 kW\u003c\/h3\u003e\u003cp\u003eModel T-REX-5KLP1G01. Full specifications are listed below.\u003c\/p\u003e\u003ch3\u003e6 kW\u003c\/h3\u003e\u003cp\u003eModel T-REX-6KLP1G01. Full specifications are listed below.\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 6 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Fault Monitoring\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Efficiency (%)\u003c\/td\u003e\n\u003ctd\u003e99.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e40-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charge Discharge Current (A)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Charge Discharge Power (W)\u003c\/td\u003e\n\u003ctd\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Supported\u003c\/td\u003e\n\u003ctd\u003eLi-Ion \/ Lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Operating Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e90-550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e100-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Short Circuit Current (A)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage Range (V)\u003c\/td\u003e\n\u003ctd\u003e184-264.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Grid Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Charge Current (A)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Passthrough (A)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Adjustable Range\u003c\/td\u003e\n\u003ctd\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD (%)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Max Output Current (A)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Output Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Output Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50\/60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti Islanding Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Monitoring\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS232\/RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMS Communication\u003c\/td\u003e\n\u003ctd\u003eCAN\/RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eWiFi\/GPRS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD+LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kg)\u003c\/td\u003e\n\u003ctd\u003e32.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight (kg)\u003c\/td\u003e\n\u003ctd\u003e39.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e530 x 493 x 228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e632 x 570 x 315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNature (3-5K) \/ Intelligent Air Cooling (6K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude (m)\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-25°C to +60°C, \u0026gt;45°C derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Standards\u003c\/td\u003e\n\u003ctd\u003eVDE-AR-N 4105, G99\/1, EN50549-1, CEI 0-21, AS 4777.2, NRS 097-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 62109-1\/2, IEC 62040-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty (years)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e39.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings Per MPPT\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"Felicity Solar","offers":[{"title":"3 kW","offer_id":47922337382505,"sku":"T-REX-3KLP1G01","price":1650.0,"currency_code":"AED","in_stock":true},{"title":"3.6 kW","offer_id":47922337415273,"sku":"T-REX-3K6LP1G01","price":1650.0,"currency_code":"AED","in_stock":true},{"title":"4 kW","offer_id":47922337448041,"sku":"T-REX-4KLP1G01","price":1650.0,"currency_code":"AED","in_stock":true},{"title":"4.6 kW","offer_id":47922337480809,"sku":"T-REX-4K6LP1G01","price":1650.0,"currency_code":"AED","in_stock":true},{"title":"5 kW","offer_id":47922337513577,"sku":"T-REX-5KLP1G01","price":1650.0,"currency_code":"AED","in_stock":true},{"title":"6 kW","offer_id":47922337546345,"sku":"T-REX-6KLP1G01","price":1650.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/t_rex_3_3_6_4_6_5_6k.jpg?v=1787208822"},{"product_id":"ivam8048p1g1","title":"Felicity Solar 8000 Off-Grid Solar Inverter","description":"\u003cp\u003eThe Felicity IVAM8048P1G1 is a off-grid inverter with specifications as published by the manufacturer. Every figure on this page is taken from the manufacturer's datasheet for the IVAM8048P1G1.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLead-acid or Lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range(V)\u003c\/td\u003e\n\u003ctd\u003e40~60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Input Voltage Range(V)\u003c\/td\u003e\n\u003ctd\u003e90~500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range(V)\u003c\/td\u003e\n\u003ctd\u003e90~425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Load MPPT Voltage Range(V)\u003c\/td\u003e\n\u003ctd\u003e200~425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Operating PV Input Current(A)\u003c\/td\u003e\n\u003ctd\u003e27+27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Input Short-Circuit Current(A)\u003c\/td\u003e\n\u003ctd\u003e40+40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. of MPP Trackers\/No. of Strings MPP Tracker\u003c\/td\u003e\n\u003ctd\u003e2\/2+2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Output Current(A)\u003c\/td\u003e\n\u003ctd\u003e34.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Waveform\u003c\/td\u003e\n\u003ctd\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Current Harmonic Distortion THDi\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charging Current(A)\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Discharging Current(A)\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Battery Input\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV access power(W)\u003c\/td\u003e\n\u003ctd\u003e16000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Input Power(W)\u003c\/td\u003e\n\u003ctd\u003e12800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Input Voltage(V)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart-up Voltage(V)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated PV Input Voltage(V)\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC Output Power(VA\/W)\u003c\/td\u003e\n\u003ctd\u003e8000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Output Power(VA\/W)\u003c\/td\u003e\n\u003ctd\u003e8000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power(W)\u003c\/td\u003e\n\u003ctd\u003e2 times of rated power, 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage(V)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Input Power to Battery (W)\u003c\/td\u003e\n\u003ctd\u003e8000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage(V)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Input Current(A)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Input Current(A)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e","brand":"Felicity Solar","offers":[{"title":"Default Title","offer_id":47922339283049,"sku":"IVAM8048P1G1","price":1.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivam8048p1g1-nobg.png?v=1787214564"},{"product_id":"ivdm4224p1g3","title":"Felicity Solar Off-Grid Solar Inverter","description":"\u003cp\u003eThe Felicity IVDM4224P1G3 is a off-grid inverter with specifications as published by the manufacturer. Every figure on this page is taken from the manufacturer's datasheet for the IVDM4224P1G3.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLead-acid or Lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range(V)\u003c\/td\u003e\n\u003ctd\u003e20-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart-up Voltage(V)\u003c\/td\u003e\n\u003ctd\u003e60-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Input Voltage Range(V)\u003c\/td\u003e\n\u003ctd\u003e60-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated PV Input Voltage(V)\u003c\/td\u003e\n\u003ctd\u003e300-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eL+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Waveform\u003c\/td\u003e\n\u003ctd\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Current Harmonic Distortion THDi\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC reverse polarity protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Overvoltage Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Short Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Load Drop Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Component Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Mode\u003c\/td\u003e\n\u003ctd\u003eWIFI\/LAN (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Topology\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Voltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II(DC), OVC III (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e8.3kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight\u003c\/td\u003e\n\u003ctd\u003e10.3kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimension\u003c\/td\u003e\n\u003ctd\u003e403x313x137mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimension\u003c\/td\u003e\n\u003ctd\u003e495x405x227mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40 to +60°C, \u0026gt;45°C Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection (IP) Rating\u003c\/td\u003e\n\u003ctd\u003eIP6X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Cooling\u003c\/td\u003e\n\u003ctd\u003eIntelligent Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e IEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2 N\u003c\/p\u003e","brand":"Felicity Solar","offers":[{"title":"Default Title","offer_id":47922339315817,"sku":"IVDM4224P1G3","price":1.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivdm4224p1g3-nobg.png?v=1787214566"},{"product_id":"ivem3024","title":"Felicity Solar 3000VA Off-Grid Solar Inverter","description":"\u003cp\u003eThe Felicity IVEM3024 is a off-grid inverter with 3000VA rated output. Every figure on this page is taken from the manufacturer's datasheet for the IVEM3024.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power(VA)\u003c\/td\u003e\n\u003ctd\u003e3000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power(W)\u003c\/td\u003e\n\u003ctd\u003e3000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e280Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz (Auto Detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency(Line Mode)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;95% (Rated R Load, Battery Full Charged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePass Through Without Battery\u003c\/td\u003e\n\u003ctd\u003eYes Utility Charge Mode Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e90-280Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charge Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Charge Protection\u003c\/td\u003e\n\u003ctd\u003eYes Solar Charging \u0026amp; Grid Charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Open Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Input Power\u003c\/td\u003e\n\u003ctd\u003e4000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Solar Charging Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charging Current(PV+Grid)\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Input Current\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Startup Voltage\u003c\/td\u003e\n\u003ctd\u003e125V Inverter Mode Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Waveform\u003c\/td\u003e\n\u003ctd\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230Vac+5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50±0.3Hz\/60Hz±0.3Hz(Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Capability\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Efficiency\u003c\/td\u003e\n\u003ctd\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Rating\u003c\/td\u003e\n\u003ctd\u003e2*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapable of Starting Electric\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Short Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight(KG)\u003c\/td\u003e\n\u003ctd\u003e10.8KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimension (MM)\u003c\/td\u003e\n\u003ctd\u003e395*295*129MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimension (MM)\u003c\/td\u003e\n\u003ctd\u003e472*372*202MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C~55°C\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE-EMC, IEC 62109-1\/2, IEC 63027\u003c\/p\u003e","brand":"Felicity Solar","offers":[{"title":"Default Title","offer_id":47922339348585,"sku":"IVEM3024","price":1.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivem3024-nobg.png?v=1787214567"},{"product_id":"ivem3048-salv","title":"Felicity Solar 18. PE Hybrid Solar Inverter","description":"\u003cp\u003eThe Felicity IVEM3048-SALV is a inverter with 18. PE rated output. Every figure on this page is taken from the manufacturer's datasheet for the IVEM3048-SALV.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e140Vac±3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Frequency\u003c\/td\u003e\n\u003ctd\u003e60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Line Frequency Disconnect\u003c\/td\u003e\n\u003ctd\u003e65±1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e18. PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePass Through Without Battery\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e127Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e65-140Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Efficiency\u003c\/td\u003e\n\u003ctd\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Charge Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Open Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Short Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eLine mode: Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV voltage range\u003c\/td\u003e\n\u003ctd\u003e120V-450V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow DC Input Shut-down\u003c\/td\u003e\n\u003ctd\u003eLoad \u0026lt; 50%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Setting\u003c\/td\u003e\n\u003ctd\u003e-15°C~+60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eMet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e7. UP button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003ctd\u003ePIN 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power\u003c\/td\u003e\n\u003ctd\u003e3000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Line Frequency Disconnect\u003c\/td\u003e\n\u003ctd\u003e47±1HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Bypass Overload Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Inverter\/Rectifier Current\u003c\/td\u003e\n\u003ctd\u003e30A\/3000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel capability\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charge Current\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Rating\u003c\/td\u003e\n\u003ctd\u003eSolar Charging \u0026amp; Grid Charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charging Current(PV+Grid)\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Startup Voltage\u003c\/td\u003e\n\u003ctd\u003e100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Array MPPT Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight(KG)\u003c\/td\u003e\n\u003ctd\u003e11.9KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight(KG)\u003c\/td\u003e\n\u003ctd\u003e14.2KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Size\u003c\/td\u003e\n\u003ctd\u003e10MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e56.4V\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e","brand":"Felicity Solar","offers":[{"title":"Default Title","offer_id":47922339414121,"sku":"IVEM3048-SALV","price":1.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivem3048-salv-nobg.png?v=1787214569"},{"product_id":"ivem5048","title":"Felicity Solar 3000VA 5000VA Hybrid Solar Inverter","description":"\u003cp\u003eThe Felicity IVEM5048 is a inverter with 3000VA 5000VA rated output. Every figure on this page is taken from the manufacturer's datasheet for the IVEM5048.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power(VA)\u003c\/td\u003e\n\u003ctd\u003e3000VA 5000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power(W)\u003c\/td\u003e\n\u003ctd\u003e3000W 5000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24V 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz (Auto detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency(Line Mode)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;95% (Rated R load, battery full charged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePass Through Without Battery\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e90-280Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charge Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Charge Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Open Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Input Power\u003c\/td\u003e\n\u003ctd\u003e4000W 6000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Solar Charging Current\u003c\/td\u003e\n\u003ctd\u003e100A 100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charging Current(PV+Grid)\u003c\/td\u003e\n\u003ctd\u003e100A 100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Input Current\u003c\/td\u003e\n\u003ctd\u003e15A 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Startup Voltage\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230Vac+5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Frequency(Hz)\u003c\/td\u003e\n\u003ctd\u003e50±0.3Hz\/60Hz±0.3Hz(Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel capability\u003c\/td\u003e\n\u003ctd\u003eYes, up to 12 units No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Efficiency\u003c\/td\u003e\n\u003ctd\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Rating\u003c\/td\u003e\n\u003ctd\u003e2* rated power for 5s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapable of Starting Electric\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Short Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight(KG)\u003c\/td\u003e\n\u003ctd\u003e9.1KG 11.2KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight(KG)\u003c\/td\u003e\n\u003ctd\u003e10.8KG 13.2KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimension (MM)\u003c\/td\u003e\n\u003ctd\u003e395*295*129MM 415*320*129MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimension (MM)\u003c\/td\u003e\n\u003ctd\u003e472*372*202MM 494*399*202MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C~55°C\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e","brand":"Felicity Solar","offers":[{"title":"Default Title","offer_id":47922339479657,"sku":"IVEM5048","price":1.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivem5048-nobg.png?v=1787214570"},{"product_id":"ivem5048-salv","title":"Felicity Solar 18. PE Hybrid Solar Inverter (IVEM5048-SALV)","description":"\u003cp\u003eThe Felicity IVEM5048-SALV is a inverter with 18. PE rated output. Every figure on this page is taken from the manufacturer's datasheet for the IVEM5048-SALV.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e140Vac±3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Frequency\u003c\/td\u003e\n\u003ctd\u003e60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Line Frequency Disconnect\u003c\/td\u003e\n\u003ctd\u003e65±1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e18. PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePass Through Without Battery\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e127Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e65-140Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Efficiency\u003c\/td\u003e\n\u003ctd\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Charge Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Open Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Short Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eBattery mode: Electronic Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV voltage range\u003c\/td\u003e\n\u003ctd\u003e120V-450V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow DC Input Shut-down\u003c\/td\u003e\n\u003ctd\u003eLoad \u0026lt; 50%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type Setting\u003c\/td\u003e\n\u003ctd\u003e-15°C~+60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e邊\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e14. Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003ctd\u003ePIN 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power\u003c\/td\u003e\n\u003ctd\u003e5000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Bypass Overload Current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Inverter\/Rectifier Current\u003c\/td\u003e\n\u003ctd\u003e50A\/5000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel capability\u003c\/td\u003e\n\u003ctd\u003eYes, up to 6 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charge Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Rating\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charging Current(PV+Grid)\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Startup Voltage\u003c\/td\u003e\n\u003ctd\u003e42.0V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Array MPPT Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight(KG)\u003c\/td\u003e\n\u003ctd\u003e14.9KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight(KG)\u003c\/td\u003e\n\u003ctd\u003e17.3KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Size\u003c\/td\u003e\n\u003ctd\u003e10MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e54V\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e","brand":"Felicity Solar","offers":[{"title":"Default Title","offer_id":47922339512425,"sku":"IVEM5048-SALV","price":1.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivem5048-salv-nobg.png?v=1787214571"},{"product_id":"ivem6048","title":"Felicity Solar Off-Grid Solar Inverter (IVEM6048)","description":"\u003cp\u003eThe Felicity IVEM6048 is a off-grid inverter with specifications as published by the manufacturer. Every figure on this page is taken from the manufacturer's datasheet for the IVEM6048.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e280Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz (Auto detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency(Line Mode)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;95% (Rated R Load, Batte Full Charged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePass Through Without Battery\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e90~280Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charge Current\u003c\/td\u003e\n\u003ctd\u003e100A 120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Charge Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax.PV Open Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Input Power\u003c\/td\u003e\n\u003ctd\u003e7000W 7500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Solar Charging Current\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charging Current(PV+Grid)\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Input Current\u003c\/td\u003e\n\u003ctd\u003e27A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Startup Voltage\u003c\/td\u003e\n\u003ctd\u003e95V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Waveform\u003c\/td\u003e\n\u003ctd\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230Vac±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e50±0.3Hz\/60Hz±0.3Hz(Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Capability\u003c\/td\u003e\n\u003ctd\u003eYes, Up to 12 Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Efficiency\u003c\/td\u003e\n\u003ctd\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapable of Starting Electric\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Short Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight(KG)\u003c\/td\u003e\n\u003ctd\u003e11.5KG 12.5KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimension (MM)\u003c\/td\u003e\n\u003ctd\u003e420*335*142MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimension (MM)\u003c\/td\u003e\n\u003ctd\u003e512*417*216MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C~50°C\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE-EMC, IEC 62109-1\/2, IEC 63027\u003c\/p\u003e","brand":"Felicity Solar","offers":[{"title":"Default Title","offer_id":47922339545193,"sku":"IVEM6048","price":1.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivem6048-nobg.png?v=1787214574"},{"product_id":"ivgm125khp3g1","title":"Felicity Solar Hybrid Solar Inverter (IVGM125KHP3G1)","description":"\u003cp\u003eThe Felicity IVGM125KHP3G1 is a hybrid inverter with specifications as published by the manufacturer. Every figure on this page is taken from the manufacturer's datasheet for the IVGM125KHP3G1.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLFP (LiFePO4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range\u003c\/td\u003e\n\u003ctd\u003e160~950Vd.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charging Current\u003c\/td\u003e\n\u003ctd\u003e120+120(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Discharging Current\u003c\/td\u003e\n\u003ctd\u003e120+120(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. DC Input Power\u003c\/td\u003e\n\u003ctd\u003e250kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e1000Vd.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart-up Voltage\u003c\/td\u003e\n\u003ctd\u003e180Vd.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e600Vd.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Range\u003c\/td\u003e\n\u003ctd\u003e150~950Vd.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Load DC Voltage Range\u003c\/td\u003e\n\u003ctd\u003e555-950Vd.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Input Current\u003c\/td\u003e\n\u003ctd\u003e10x45(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Isc\u003c\/td\u003e\n\u003ctd\u003e10x68(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC Input\/Output Power\u003c\/td\u003e\n\u003ctd\u003e125kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Input\/Output Power\u003c\/td\u003e\n\u003ctd\u003e137kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input\/Output Rated Current\u003c\/td\u003e\n\u003ctd\u003e181.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Input\/Output Current\u003c\/td\u003e\n\u003ctd\u003e198.6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC Voltage\u003c\/td\u003e\n\u003ctd\u003e220\/380,230\/400 Vac (-20%~+15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Wiring Mode\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz (45~55 Hz\/55-65 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHDi\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3% (At\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.8( leading) to 0.8( lagging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Injection Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.5% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Voltage Category\u003c\/td\u003e\n\u003ctd\u003eOVC II (DC), OVC III(AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Topology\u003c\/td\u003e\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Compatible\u003c\/td\u003e\n\u003ctd\u003eUp to 12 in parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Module\u003c\/td\u003e\n\u003ctd\u003eWIFI\/Bluetooth\/4G\/LAN(optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Style\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e155.5KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e198KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimension (MM)\u003c\/td\u003e\n\u003ctd\u003e1271*810*364MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimension (MM)\u003c\/td\u003e\n\u003ctd\u003e1410*960*646MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40 to 60 °C (\u0026gt; 45 °C derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0-100% (No condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e IEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/p\u003e","brand":"Felicity Solar","offers":[{"title":"Default Title","offer_id":47922339610729,"sku":"IVGM125KHP3G1","price":1.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivgm125khp3g1-nobg.png?v=1787214576"},{"product_id":"ivgm25khp3g3","title":"Felicity Solar Hybrid Solar Inverter","description":"\u003cp\u003eThe Felicity IVGM25KHP3G3 is a hybrid inverter with specifications as published by the manufacturer. Every figure on this page is taken from the manufacturer's datasheet for the IVGM25KHP3G3.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLFP (LiFePO4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range\u003c\/td\u003e\n\u003ctd\u003e160~700Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charging Current\u003c\/td\u003e\n\u003ctd\u003e50(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Discharging Current\u003c\/td\u003e\n\u003ctd\u003e50(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. DC Access Power\u003c\/td\u003e\n\u003ctd\u003e50kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. DC Input Power\u003c\/td\u003e\n\u003ctd\u003e40kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e1000Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e150Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart-up Voltage\u003c\/td\u003e\n\u003ctd\u003e200Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e600Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Range\u003c\/td\u003e\n\u003ctd\u003e200~850Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Load DC Voltage Range\u003c\/td\u003e\n\u003ctd\u003e666-850Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Input Current\u003c\/td\u003e\n\u003ctd\u003e30+30(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Isc\u003c\/td\u003e\n\u003ctd\u003e39+39(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.of Strings Per MPP Tracker\u003c\/td\u003e\n\u003ctd\u003e2+2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC Input\/Output Power\u003c\/td\u003e\n\u003ctd\u003e25kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Input\/Output Apparent Power\u003c\/td\u003e\n\u003ctd\u003e27.5kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input\/Output Rated Current\u003c\/td\u003e\n\u003ctd\u003e36.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Current\u003c\/td\u003e\n\u003ctd\u003e39.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power(off-grid) (W)\u003c\/td\u003e\n\u003ctd\u003e1.5times of\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC Voltage\u003c\/td\u003e\n\u003ctd\u003e220\/380,230\/400 Vac (-20%~+15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Wiring Mode\u003c\/td\u003e\n\u003ctd\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz (45~55 Hz\/55~65 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHDi\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3% (At\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.8( leading) to 0.8( lagging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Injection Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.5% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Module\u003c\/td\u003e\n\u003ctd\u003eWiFi\/4G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e41.4KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight\u003c\/td\u003e\n\u003ctd\u003e47.4KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimension\u003c\/td\u003e\n\u003ctd\u003e642*445*237.5MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimension\u003c\/td\u003e\n\u003ctd\u003e784*563*367MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Style\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40 to 60°C(\u0026gt;45°C Derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0~95% (No Condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e IEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/p\u003e","brand":"Felicity Solar","offers":[{"title":"Default Title","offer_id":47922339643497,"sku":"IVGM25KHP3G3","price":1.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ivgm25khp3g3-nobg.png?v=1787214577"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/collections\/SUN-3.6-10K-SG05LP1-SM2_83996c38-ee70-4340-86e7-8ffd762d7407.png?v=1785786669","url":"https:\/\/www.solarinstaller.ae\/collections\/solar-inverters.oembed?page=3","provider":"Solar Installer","version":"1.0","type":"link"}