{"title":"Solar Air Conditioners","description":"\u003cp\u003eCooling that runs directly from solar, cutting daytime grid draw.\u003c\/p\u003e","products":[{"product_id":"acdcblw","title":"Deye 12,000–24,000 BTU AC\/DC Hybrid Solar Air Conditioner","description":"\u003cp\u003e\u003cstrong\u003eDeye 12,000–24,000 BTU AC\/DC Hybrid Solar Air Conditioner\u003c\/strong\u003e, available in 3 ratings, 12,000 BTU to 24,000 BTU. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e2 Years manufacturer warranty\u003c\/li\u003e\n\u003cli\u003eCertified to CE\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e12,000 BTU solar air conditioner for a 12 to 20 m² bedroom or office\u003c\/h3\u003e\u003cp\u003eThis one covers a bedroom or a small office of 12 to 20 m², and it is the only size in the range that meets its nameplate exactly: 12,000 BTU of rated cooling in T1 conditions. Three to four 330 W panels in series drive it. At 42.5 dB indoors it is the quietest of the three, it pulls 1.3 litres of water an hour out of the air, and the outdoor unit is 33.5 kg net.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels needed: 3-4 x 330 W in series · Room size: 12-20 m² · Rated cooling (T1): 12,000 BTU · Indoor noise: 42.5 dB\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: ACDCBLW-DGA2-ACDCBLW-12K\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e18,000 BTU solar air conditioner for a 20 to 30 m² living room or shop\u003c\/h3\u003e\u003cp\u003eFor a living room or a shop of 20 to 30 m². Read the rating carefully: it is sold as 18K, but measured T1 capacity is 17,300 BTU, and that falls to 14,700 BTU in T3 heat, which is the number that counts in a Gulf summer. It runs on three to six 330 W panels, moves 980 cubic metres of air an hour on turbo, and the outdoor unit is 37 kg net.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels needed: 3-6 x 330 W in series · Room size: 20-30 m² · Rated cooling (T1): 17,300 BTU · Cooling in T3 heat: 14,700 BTU\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: ACDCBLW-DGA1-ACDCBLW-18K\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e24,000 BTU solar air conditioner for a 30 to 42 m² room or shop floor\u003c\/h3\u003e\u003cp\u003eThe largest, for an open floor of 30 to 42 m². It is the only one built around a Panasonic compressor, model 5RD198, and the only one that will run refrigerant pipe out to 25 m, which helps when the outdoor unit has to sit up on a roof. Rated T1 cooling is 22,000 BTU and it takes three to eight 330 W panels. Plan the lift, because the outdoor unit is 50 kg net.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003ePanels needed: 3-8 x 330 W in series · Room size: 30-42 m² · Rated cooling (T1): 22,000 BTU · Max refrigerant pipe run: 25 m\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: ACDCBLW-DGA1-ACDCBLW-24K\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 3 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU)\u003c\/td\u003e\n\u003ctd\u003e12000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolar Module (W)\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Power Limiter (W)\u003c\/td\u003e\n\u003ctd\u003e0-600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e1Ph 208V-240V\/50-60HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC PV Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e80-380V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Current (A)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended PV Panels\u003c\/td\u003e\n\u003ctd\u003e12K: (3-4)*330W in series | 18K: (3-6)*330W in series | 24K: (3-8)*330W in series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity T1 (W)\u003c\/td\u003e\n\u003ctd\u003e12K: 3510(900-3900) | 18K: 5070(1200-6000) | 24K: 6450(1800-7900)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Power Input T1 (W)\u003c\/td\u003e\n\u003ctd\u003e12K: 940(190-1270) | 18K: 1400(220-2100) | 24K: 1790(300-3200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity Rated (W)\u003c\/td\u003e\n\u003ctd\u003e12K: 4100(1000-4500) | 18K: 6100(1200-6800) | 24K: 7800(1800-9100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power Input (W)\u003c\/td\u003e\n\u003ctd\u003e12K: 1170(190-1700) | 18K: 1770(220-2500) | 24K: 2290(300-3500)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER T1\u003c\/td\u003e\n\u003ctd\u003e12K: 3.75 W\/W · 12.75 BTU\/W | 18K: 3.60 W\/W · 12.35 BTU\/W | 24K: 3.60 W\/W · 12.30 BTU\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e12K: 3.50 W\/W · 11.95 BTU\/W | 18K: 3.45 W\/W · 11.75 BTU\/W | 24K: 3.40 W\/W · 11.60 BTU\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Model\u003c\/td\u003e\n\u003ctd\u003e12K: WHP04200 | 18K: WHP05600 | 24K: 5RD198\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Configuration\u003c\/td\u003e\n\u003ctd\u003e2xRotary Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Brand\u003c\/td\u003e\n\u003ctd\u003e12K: Highly | 18K: Highly | 24K: Panasonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Fan Motor\u003c\/td\u003e\n\u003ctd\u003e12K: BLDC-15W | 18K: BLDC-45W | 24K: BLDC-45W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Fan Speed RPM\u003c\/td\u003e\n\u003ctd\u003e12K: 1300\/1200\/1100\/950 | 18K: 1050\/950\/850\/750 | 24K: 1350\/1250\/1150\/1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (m³\/h)\u003c\/td\u003e\n\u003ctd\u003e12K: 540\/485\/435\/350 | 18K: 980\/880\/740\/620 | 24K: 1290\/1180\/1070\/900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Packing Dimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e12K: 920×290×360 | 18K: 1140×300×382 | 24K: 1140×300×382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Fan Motor\u003c\/td\u003e\n\u003ctd\u003e12K: BLDC-40W | 18K: BLDC-55W | 24K: BLDC-75W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Fan Speed RPM\u003c\/td\u003e\n\u003ctd\u003e12K: 880 | 18K: 880 | 24K: 850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow (m³\/h)\u003c\/td\u003e\n\u003ctd\u003e12K: 2100 | 18K: 2200 | 24K: 3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Packing Dimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e12K: 910×622×405 | 18K: 910×622×405 | 24K: 1006×755×418\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Design Pressure Mpa\u003c\/td\u003e\n\u003ctd\u003e4.3 MPa discharge \/ 1.5 MPa suction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Pipe Size\u003c\/td\u003e\n\u003ctd\u003e12K: 3\/8″ gas \/ 1\/4″ liquid | 18K: 1\/2″ gas \/ 1\/4″ liquid | 24K: 1\/2″ gas \/ 1\/4″ liquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length (m)\u003c\/td\u003e\n\u003ctd\u003e12K: 15 | 18K: 20 | 24K: 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Level Difference (m)\u003c\/td\u003e\n\u003ctd\u003e12K: 8 | 18K: 10 | 24K: 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Size (mm)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied Pipe Length (m)\u003c\/td\u003e\n\u003ctd\u003e12K: 3 | 18K: 4 | 24K: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Wire Length (m)\u003c\/td\u003e\n\u003ctd\u003e12K: 4 | 18K: 5 | 24K: 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic Expansion Valve\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContainer Loading Quantity\u003c\/td\u003e\n\u003ctd\u003e12K: 200 × 40'HQ \/ 85 × 20'GP | 18K: 160 × 40'HQ \/ 75 × 20'GP | 24K: 115 × 40'HQ \/ 50 × 20'GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-10 to 58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimate Type\u003c\/td\u003e\n\u003ctd\u003eT3\/T1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Area By Model\u003c\/td\u003e\n\u003ctd\u003e12K: 12-20 | 18K: 20-30 | 24K: 30-42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification Lh\u003c\/td\u003e\n\u003ctd\u003e12K: 1.3 | 18K: 1.7 | 24K: 2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Noise Level (dB)\u003c\/td\u003e\n\u003ctd\u003e12K: ≤42.5 | 18K: ≤46 | 24K: ≤50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise (dB)\u003c\/td\u003e\n\u003ctd\u003e12K: ≤52 | 18K: ≤55 | 24K: ≤58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e910 x 622 x 405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"12,000 BTU","offer_id":47869742448745,"sku":"DEYE-ACDCBLW-DGA2-ACDCBLW-12K","price":2572.0,"currency_code":"AED","in_stock":true},{"title":"18,000 BTU","offer_id":47869742481513,"sku":"DEYE-ACDCBLW-DGA1-ACDCBLW-18K","price":2572.0,"currency_code":"AED","in_stock":true},{"title":"24,000 BTU","offer_id":47869742514281,"sku":"DEYE-ACDCBLW-DGA1-ACDCBLW-24K","price":2572.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/ACDCBLW_Heater.png?v=1785851417"},{"product_id":"dc48v","title":"Deye 9,000–24,000 BTU 48 V DC Off-Grid Solar Air Conditioner","description":"\u003cp\u003e\u003cstrong\u003eDeye 9,000–24,000 BTU 48 V DC Off-Grid Solar Air Conditioner\u003c\/strong\u003e, available in 4 ratings, 9,000 BTU to 24,000 BTU. Each rating is a different machine with its own figures. Pick the one that matches your system below, then select it in the options above.\u003c\/p\u003e\u003ch2\u003eTrue of every rating\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e2 Years manufacturer warranty\u003c\/li\u003e\n\u003cli\u003eCertified to CE\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoose your rating\u003c\/h2\u003e\u003ch3\u003e9,000 BTU 48V DC solar air conditioner for a bedroom of 8 to 12 m²\u003c\/h3\u003e\u003cp\u003eThe smallest of the four and the most efficient, at 3.90 W\/W in T1 conditions against 3.50 for the 18K and 24K. It draws 680 W while cooling at its rated 2,600 W, and it is the quietest indoors at 40 dB. A single GMCC rotary inverter compressor and a one-row outdoor coil keep the outdoor unit down to 28 kg. Refrigerant pipe can run up to 15 m from the wall.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated cooling: 2,600 W · Power drawn while cooling: 680 W · Efficiency (EER, T1): 3.90 W\/W · Room size: 8 to 12 m²\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: DC48V-09K\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e12,000 BTU DC solar air conditioner for a 12 to 20 m² living room\u003c\/h3\u003e\u003cp\u003eIt gives 3,510 W of cooling for 980 W drawn, which works out at 3.60 W\/W, and it is the size for a 12 to 20 square metre room. The compressor brand and outdoor cabinet match the 9K, but a second coil row takes the outdoor unit to 32 kg. Dehumidification runs at 1.3 litres an hour. In T3 heat, the sort of summer the Gulf gets, cooling settles at 9,900 BTU.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated cooling: 3,510 W · Power drawn while cooling: 980 W · Efficiency (EER, T1): 3.60 W\/W · Room size: 12 to 20 m²\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: DC48V-12K\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e18,000 BTU off-grid solar air conditioner for a 20 to 30 m² shop\u003c\/h3\u003e\u003cp\u003eTwin Highly rotary inverter compressors take this one to 5,070 W of cooling, enough for a 20 to 30 square metre shop or office. It is also the best heater in the range, at 3.75 W\/W, putting out 5,250 W of heat. Pipe runs stretch to 20 m and the indoor unit grows to a 1,080 mm case moving 980 cubic metres an hour on turbo. Indoor noise reaches 46 dB.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated cooling: 5,070 W · Power drawn while cooling: 1,450 W · Heating efficiency (COP): 3.75 W\/W · Room size: 20 to 30 m²\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: DC48V-18K\u003c\/small\u003e\u003c\/p\u003e\u003ch3\u003e24,000 BTU 48V solar air conditioner for an open room up to 40 m²\u003c\/h3\u003e\u003cp\u003eThe big one, at 6,450 W of cooling from twin Panasonic rotary inverter compressors, sized for an open room of 30 to 40 square metres. Its outdoor unit is the only one in a larger cabinet, 900 by 700 by 337 mm and 51 kg, shifting 3,300 cubic metres of air an hour. Pipe runs go to 25 m and dehumidification reaches 2.5 litres an hour. It is the loudest indoors, at 50 dB.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRated cooling: 6,450 W · Power drawn while cooling: 1,840 W · Outdoor unit weight: 51 kg net · Room size: 30 to 40 m²\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eModel code: DC48V-24K\u003c\/small\u003e\u003c\/p\u003e\u003cdetails class=\"deye-specs\"\u003e\u003csummary\u003eFull specifications shared across all 4 ratings\u003c\/summary\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU)\u003c\/td\u003e\n\u003ctd\u003e9000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage (V)\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Models\u003c\/td\u003e\n\u003ctd\u003e9K, 12K, 18K, 24K BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Power Supply\u003c\/td\u003e\n\u003ctd\u003eDC48V(46~58V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity T1 (W)\u003c\/td\u003e\n\u003ctd\u003e9K: 2600(1000-3400) | 12K: 3510(1000-3700) | 18K: 5070(1200-5250) | 24K: 6450(2500-7000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Power Input T1 (W)\u003c\/td\u003e\n\u003ctd\u003e9K: 680(180-1060) | 12K: 980(200-1200) | 18K: 1450(220-1780) | 24K: 1840(450-2230)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity Rated (W)\u003c\/td\u003e\n\u003ctd\u003e9K: 2900(800-3050) | 12K: 3900(1000-4100) | 18K: 5250(1200-5500) | 24K: 7000(2000-7350)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power Input (W)\u003c\/td\u003e\n\u003ctd\u003e9K: 830(160-950) | 12K: 1130(180-1280) | 18K: 1400(220-1830) | 24K: 2050(390-2350)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER T1\u003c\/td\u003e\n\u003ctd\u003e9K: 3.90 W\/W · 13.20 BTU\/W | 12K: 3.60 W\/W · 12.25 BTU\/W | 18K: 3.50 W\/W · 11.8 BTU\/W | 24K: 3.50 W\/W · 11.85 BTU\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e9K: 3.50 W\/W · 11.90 BTU\/W | 12K: 3.45 W\/W · 11.75 BTU\/W | 18K: 3.75 W\/W · 12.80 BTU\/W | 24K: 3.40 W\/W · 11.70 BTU\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Model\u003c\/td\u003e\n\u003ctd\u003e9K: ASK89D53UEZ | 12K: ASN98D22UFZ | 18K: WHP05600 | 24K: 5RD198\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Configuration\u003c\/td\u003e\n\u003ctd\u003e9K: Rotary Inverter | 12K: Rotary Inverter | 18K: 2xRotary Inverter | 24K: 2xRotary Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Brand\u003c\/td\u003e\n\u003ctd\u003e9K: GMCC | 12K: GMCC | 18K: HIGHLY | 24K: Panasonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Fan Motor\u003c\/td\u003e\n\u003ctd\u003e9K: BLDC 15W | 12K: BLDC 15W | 18K: BLDC 45W | 24K: BLDC 45W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Fan Speed RPM\u003c\/td\u003e\n\u003ctd\u003e9K: 1200\/1100\/1000\/850 | 12K: 1300\/1200\/1100\/950 | 18K: 1050\/950\/850\/750 | 24K: 1350\/1250\/1150\/1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (m³\/h)\u003c\/td\u003e\n\u003ctd\u003e9K: 485\/435\/380\/305 | 12K: 540\/485\/435\/350 | 18K: 980\/880\/740\/620 | 24K: 1290\/1180\/1070\/900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Packing Dimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e9K: 920×290×360 | 12K: 920×290×360 | 18K: 1140×300×382 | 24K: 1140×300×382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Fan Motor\u003c\/td\u003e\n\u003ctd\u003e9K: BLDC 40W | 12K: BLDC 40W | 18K: BLDC 55W | 24K: BLDC 75W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Fan Speed RPM\u003c\/td\u003e\n\u003ctd\u003e9K: 880 | 12K: 880 | 18K: 880 | 24K: 850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Coil Rows\u003c\/td\u003e\n\u003ctd\u003e9K: 1 | 12K: 2 | 18K: 2 | 24K: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Coil Tube\u003c\/td\u003e\n\u003ctd\u003e9K: Φ7,innergroove tube | 12K: Φ7,innergroove tube | 18K: Φ9.52,innergroove tube | 24K: Φ9.52,innergroove tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow (m³\/h)\u003c\/td\u003e\n\u003ctd\u003e9K: 2000 | 12K: 2100 | 18K: 2200 | 24K: 3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Packing Dimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e9K: 910×622×405 | 12K: 910×622×405 | 18K: 910×622×405 | 24K: 1006×755×418\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR410a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Design Pressure Mpa\u003c\/td\u003e\n\u003ctd\u003e9K: 4.3 MPa discharge \/ 1.5 MPa suction | 12K: 4.3 MPa discharge \/ 1.5 MPa suction | 18K: 4.3 MPa discharge \/ 1.5 MPa suction | 24K: 4.3 MPa discharge \/ 1.1 MPa suction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Pipe Size\u003c\/td\u003e\n\u003ctd\u003e9K: 3\/8″ gas \/ 1\/4″ liquid | 12K: 3\/8″ gas \/ 1\/4″ liquid | 18K: 1\/2″ gas \/ 1\/4″ liquid | 24K: 1\/2″ gas \/ 1\/4″ liquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length (m)\u003c\/td\u003e\n\u003ctd\u003e9K: 15 | 12K: 15 | 18K: 20 | 24K: 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Level Difference (m)\u003c\/td\u003e\n\u003ctd\u003e9K: 8 | 12K: 8 | 18K: 10 | 24K: 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Size (mm)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied Pipe Length (m)\u003c\/td\u003e\n\u003ctd\u003e9K: 3 | 12K: 3 | 18K: 4 | 24K: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Wire Length (m)\u003c\/td\u003e\n\u003ctd\u003e9K: 4 | 12K: 4 | 18K: 5 | 24K: 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic Expansion Valve\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContainer Loading Quantity\u003c\/td\u003e\n\u003ctd\u003e9K: 200 × 40'HQ \/ 85 × 20'GP | 12K: 200 × 40'HQ \/ 85 × 20'GP | 18K: 160 × 40'HQ \/ 75 × 20'GP | 24K: 115 × 40'HQ \/ 50 × 20'GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-10 to 58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimate Type\u003c\/td\u003e\n\u003ctd\u003eT1\/T3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Area By Model\u003c\/td\u003e\n\u003ctd\u003e9K: 8-12 | 12K: 12-20 | 18K: 20-30 | 24K: 30-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification Lh\u003c\/td\u003e\n\u003ctd\u003e9K: 1 | 12K: 1.3 | 18K: 1.7 | 24K: 2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Noise Level (dB)\u003c\/td\u003e\n\u003ctd\u003e9K: ≤40 | 12K: ≤42.5 | 18K: ≤46 | 24K: ≤50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise (dB)\u003c\/td\u003e\n\u003ctd\u003e9K: ≤51 | 12K: ≤52 | 18K: ≤55 | 24K: ≤58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e44.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e910 x 622 x 405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"DEYE","offers":[{"title":"9,000 BTU","offer_id":47869743792233,"sku":"DEYE-DC48V-09K","price":3165.0,"currency_code":"AED","in_stock":true},{"title":"12,000 BTU","offer_id":47869743825001,"sku":"DEYE-DC48V-12K","price":3165.0,"currency_code":"AED","in_stock":true},{"title":"18,000 BTU","offer_id":47869743857769,"sku":"DEYE-DC48V-18K","price":3165.0,"currency_code":"AED","in_stock":true},{"title":"24,000 BTU","offer_id":47869743890537,"sku":"DEYE-DC48V-24K","price":3165.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/4871\/4089\/files\/DC48V.png?v=1785851432"}],"url":"https:\/\/www.solarinstaller.ae\/collections\/solar-air-conditioners.oembed","provider":"Solar Installer","version":"1.0","type":"link"}